40DR MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 1/6 https://www.m-system.co.jp/ Digital Panel Meters 40 Series RTD INPUT DIGITAL PANEL METER (4 digits, process meter) Functions & Features
- 4 digit (±9999) panel meter
- HOLD functions
- High visible, 0.8" (20.3mm) high and bright LED mm (inch) 96 (3.78) (1.89) 96 (3.78) MODEL: 40DR–R1–[1][2]
ORDERING INFORMATION
- Code number: 40DR–R1–[1][2] Specify a code from below for each of [1] and [2]. (e.g. 40DR-R1-R/Q)
- Specify the specification for option code /Q (e.g. /C01/SET) INPUT R1: Pt 100 (JIS'97, IEC) (Usable range -200 to +850°C, -328 to +1562°F) Pt 100 (JIS'89) (Usable range -200 to +650°C, -328 to +1202°F) [1] POWER INPUT AC Power K3: 100 – 120V AC (Operational voltage range 85 - 132 V, 47 - 66 Hz) L3: 200 – 240V AC (Operational voltage range 170 - 264 V, 47 - 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±20 %, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9533) GENERAL SPECIFICATIONS Construction: Panel flush mounting Connection: M3 screw terminals (torque 0.6 N·m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input to power A/D conversion: Σ – Δ Sampling rate: 10 times/sec. (100 msec.) Averaging: None or moving average Setting: (Front button)
- Temperature unit
- Moving average
- Brightness
- Others ■Recommended solderless terminal 6 (.24) max 3.3 (.13) max mm (inch) DISPLAY Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment, red LED Display range: -9999 to 9999 Decimal point position: 10–1 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: 'S.ERR' blinks surpassing the permissible range. 'B.ERR' blinks at burnout. Engineering unit indication: Sticker label attached DC, AC, mV, V, kV, μA, mA, A, kA, mW, W, kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec, m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h,
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 2/6 https://www.m-system.co.jp/ N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J, kJ, MJ, rpm, sec, min, pH, %, ppm, etc. INPUT SPECIFICATIONS ■ RTD (3-wire) Maximum leadwire resistance: 10 Ω per wire Sensing current: Approx. 0.5 mA Usable range (conformance range): Pt100 (JIS’97, IEC) -200 to +850℃ or -328 to +1562°F Pt100 (JIS’89) -200 to +650℃ or -328 to +1202°F Operational range: -230 to +880℃ or -382 to +1616°F ■ Hold Input: Dry contact input Detecting level: ≤ 1.5 V Sensing: Approx. 5 V DC, 1 mA INSTALLATION Power consumption
- AC: Approx. 1.3 VA for 100 – 120 V Approx. 1.2 VA for 200 – 240 V
- DC: Approx. 0.5 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 160 g (0.35 lb) PERFORMANCE Accuracy -200 – +200°C: ±0.2°C rdg ±1 digit 200 – 850°C: ±0.6°C rdg ±1 digit -328 – +1562°F: ±1°F rdg ±1 digit Temp. coefficient: ±0.1 ℃/℃ Line voltage effect: ±1 digit over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @1 minute (input to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input to power: Reinforced insulation (300 V) RoHS Directive
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 3/6 https://www.m-system.co.jp/ DISPLAY HOLD COMMAND Displayed value is held with an external HOLD command input. Connect the contacts across HOLD to COM. L HOLD H Twisted pair cable L HOLD H L HOLD H L HOLD H Twisted pair cable Twisted pair cable COM COM (b) Transistor (a) 5V–CMOS, TTL (c) Photo-Coupler (d) Relay Relay Photo-Coupler HOLD
5 HOLD
5 HOLD 6
(2) Sticker Label (1) Front Panel (5) Disp/ Button (3) 4-digit Display (4) Polarity Indicator (6) Scale/ Button (8) Up Button (7) Shift Button ■ COMPONENT IDENTIFICATION No. COMPONENT FUNCTIONS (1) Front panel Removed at conguration. (2) Sticker label Engineering unit label position (3) 4-digit display 4-digit LED display. Range: 0 to 9999 (not including decimal point) (4) Polarity indicator Turns on when negative value is displayed (5) Used to move on to the display setting modes; or to shift through setting items in each setting mode. (6) Used to move on to the zero & span adjustment modes; or to shift through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status and shift through display digits in each set- ting item. (8) Up button Used to select setting value. Disp/ button Scale/ button
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 4/6 https://www.m-system.co.jp/ PARAMETER LIST ■ ZERO & SPAN ADJUSTMENTS PARAMETER DISPLAY FUNCTION DEFAULT VALUE Zero adjustment – Adjustment value for -200°C To distinguish from span adjustment, the /f_i rst decimal point is blink- ing Span adjustment – Adjustment value for 850°C Temperature unit Display in Celsius Display in Fahrenheit (Temperature range: -328 to +1562°F)*1 Decimal Point Position 10 or none Decimal point position for celsius *1 . For Fahrenheit, the value is rounded to integer. Decimal point position setting is not available. ■ DISPLAY SETTING MODE PARAMETER DISPLAY FUNCTION DEFAULT VALUE Moving Average No moving averaging Moving average with 2 samples Moving average with 4 samples Moving average with 8 samples Moving average with 16 samples Brightness Brightness level 1 (dark) Brightness level 2 Brightness level 3 Brightness level 4 Brightness level 5 (bright) Initialization Non-initialization Initialize settings (change to factory settings) *1 Version Indication − Version number, indication only − *1 . While “ ” is shown, pressing Disp/ button or Scale/ button initializes settings. Activating “initialization” , user’s speci/f_i ed parameters will be deleted and overwritten with the factory default values. Notice that after this, Ex-factory settings will be irrecoverable.
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 5/6 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 92 (3.62) 45 (1 .77) 85 (3.35)11 (.43) 96 (3.78) 96 (3.78) 48 (1 .89) 103 (4.06) 10–M3 SCREW TERMINALS ■ TOP VIEW ■ FRONT VIEW ■ SIDE VIEW ■ REAR VIEW 1 2 3 4 5 6 7 8 9 10 6.4 (.25) 12 (.47) 4 (.16) MOUNTING REQUIREMENTS unit: mm + 0.8 – 0 + 0.6 – 0 min. 120 min. 75 Panel thickness: 1.6 to 8.0 mm
MODEL: 40DR 40DR SPECIFICATIONS ES-9533 Rev.10 Page 6/6 https://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM B B RTD Display / Setting A/D Converter Digital Computation POWER U(+) V(–) COM HOLD Specifications are subject to change without notice.