MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 1/7 https://www.m-system.co.jp/ Digital Panel Meters 40 Series AC VOLTAGE INPUT DIGITAL PANEL METER (4 digit, process meter, true RMS sensing) Functions & Features

  • 4 digit (±9999) panel meter
  • Scaling and HOLD functions
  • High visible, 0.8" (20.3mm) high and bright LED mm (inch) 96 (3.78) (1.89) 96 (3.78) MODEL: 40DPT–[1]–[2][3]

ORDERING INFORMATION

  • Code number: 40DPT–[1]–[2][3] Specify a code from below for each of [1] through [3]. (e.g. 40DPT-V1-K3/Q)
  • Specify the specification for option code /Q (e.g. /C01/SET) [1] INPUT Voltage V1: 0.0 - 200.0 mV AC (Conformance range) (Input range: 0.0 – 240.0 mV AC, Input resistance: ≥100 kΩ) V2: 0.000 - 2.000 V AC (Conformance range) (Input range: 0.000 – 2.400 V AC, Input resistance: ≥1 MΩ) V3: 0.00 - 20.00 V AC (Conformance range) (Input range: 0.00 – 24.00 V AC, Input resistance: ≥1 MΩ) V4: 0.0 - 200.0 V AC (Conformance range) (Input range: 0.0 – 240.0 V AC, Input resistance: ≥1 MΩ) V5: 0.0 - 400.0 V AC (Conformance range) (Input range: 0.0 – 480.0 V AC, Input resistance: ≥1 MΩ) (CE not available) [2] POWER INPUT AC Power K3: 100 – 120V AC (Operational voltage range 85 - 132 V, 47 - 66 Hz) L3: 200 – 240V AC (Operational voltage range 170 - 264 V, 47 - 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±20 %, ripple 10 %p-p max.) [3] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9537) GENERAL SPECIFICATIONS Construction: Panel flush mounting Connection: M3 screw terminals (torque 0.6 N·m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input to power Input waveform RMS sensing: Up to 15 % of 3rd harmonic content Sampling rate: 10 times/sec. (100 msec.) Averaging: None or moving average Setting: (Front button)
  • Scaled range
  • Low-end cutout
  • Moving average
  • Brightness
  • Others ■Recommended solderless terminal 6 (.24) max 3.3 (.13) max mm (inch)

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 2/7 https://www.m-system.co.jp/ DISPLAY Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment, red LED Display range: -9999 to 9999 Scaling range: -9999 to 9999 counts Decimal point position: 10-1, 10-2, 10-3 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: '-9999' or '9999' blinking for display values out of the display range. 'S.ERR' blinks surpassing the permissible range. 'ERR' blinks when input scaling setting is inappropriate. Engineering unit indication: Sticker label attached DC, AC, mV, V, kV, μA, mA, A, kA, mW, W, kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec, m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h, N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J, kJ, MJ, rpm, sec, min, pH, %, ppm, etc. INPUT SPECIFICATIONS ■ AC Input voltage Frequency: 40 - 100 Hz Overload capacity: 120 % of max. measurement range (continuous)

  • V1 Max. input: 10 V
  • V2 Max. input: 100 V
  • V3, V4, V5 Max. input: 500 V Input burden: ≤ 0.5 VA ■ Hold Input: Dry contact input Detecting level: ≤ 1.5 V Sensing: Approx. 5 V DC, 1 mA INSTALLATION Power consumption
  • AC: ≤ 2.7 VA for 100 – 120 V ≤ 3.4 VA for 200 – 240 V
  • DC: ≤ 1.0 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 180 g (0.40 lb) PERFORMANCE Input accuracy: ±0.3% rdg ±1digit, < 35 % of full scale: ±0.3% FS ±1digit Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Line voltage effect: ±0.2 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category I (input) Installation Category II (power) Pollution degree 2 Input to power: Reinforced insulation (300 V) RoHS Directive

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 3/7 https://www.m-system.co.jp/ DISPLAY HOLD COMMAND Displayed value is held with an external HOLD command input. Connect the contacts across HOLD to COM. (Isolate with photo-coupler or relay as terminals 3 and 4 are not isolated to input signal, terminals 1 and 2.) L HOLD H L HOLD H Twisted pair cable Twisted pair cable COM (a) Photo-Coupler (b) Relay Relay Photo-Coupler HOLD COM HOLD EXTERNAL VIEW (2) Sticker Label (1) Front Panel (5) Disp/ Button (3) 4-digit Display (4) Polarity Indicator (6) Scale/ Button (8) Up Button (7) Shift Button ■ FUNCTION TABLE No. COMPONENT FUNCTIONS (1) Front panel Removed at configuration. (2) Sticker label Engineering unit label position (3) 4-digit display 4-digit LED display. Range: 0 to 9999 (not including decimal point) (4) Polarity indicator Turns on when negative value is displayed. (5) Disp/ button Used to move on to the display setting modes, to shift through setting items in each setting mode, or shift through display digits in each setting item. (6) Scale/ button Used to move on to the scaling setting modes, to shift through setting items in each setting mode, or shift through display digits in each setting item. (7) Shift button Used to move on to the setting standby status. (8) Up button Used to select setting value.

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 4/7 https://www.m-system.co.jp/ PARAMETER LIST ■ SCALING SETTING MODE Input value to be set as Zero in the measurement range – Display value for input scaling value B Low-end cutout OFF Low-end cutout ON Absolute value low-end cutout ON Low-end cutout value setting Display value for input scaling value A Decimal point position4th LSD – 2nd LSD, none FUNCTION DEFAULT VALUE INPUT CODEDISPLAYITEM DISPLAY PARAMETER Decimal Point Position Low-end cutout value Input Scaling Value A Input Scaling Value B Display Scaling Value A Display Scaling Value B Low-end cutout Input value to be set as Full Scale in the measurement range *1 . Only for input code ‘V5’ *2. Input signal less than the preset cutout value is forcibly cut to display scaling value “zero” . Use when minus value is not required. Lower 3 digits of displayed value are set regardless of decimal point posi tion. Note: With the low-end cutout or absolute value low-end cutout set to ON, the low-end cutout value setti ng is valid. *1)

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 5/7 https://www.m-system.co.jp/

  • Input scaling Zero and full scale of input range can be re-configured to user's desired value by entering parameters. When initialization of setting is executed, these data is lost and return to the default value. Input Scaling Value A: Input value for zero point (Input scaling value A < Input scaling value B) Enter the value you want to set to zero in the measurement range. Input Scaling Value B: Input value for full scale point Enter the value you want to set to full scale in the measurement range.
  • Display scaling Display Scaling Value A: Display value for Input Scaling Value A Display Scaling Value B: Display value for Input Scaling Value B
  • Normal Scaling The display value increases when the input signal increases.
  • Inverted Scaling The display value decreases when the input signal increases. A A B B Display Zero Full Scale Input Input Scaling Display Scaling B A B A Display Full Scale Zero Input Input Scaling Display Scaling Decimal point position: Decimal point position is specified independently from the scaling. When you set the display scaling, include zeros for fractions. ■ DISPLAY SETTING MODE PARAMETER ITEM DISPLAY DISPLAY FUNCTION Moving Average No moving averaging Moving average with 2 samples Moving average with 4 samples Moving average with 8 samples Moving average with 16 samples Brightness Brightness level 0 (dark) Brightness level 1 Brightness level 2 Brightness level 3 Brightness level 4 Brightness level 5 (bright) Initialization Non-initialization Initialize settings (change to factory settings) *1 Version Indication – – Version number, indication only *1. While “on” is shown, pressing Shift button initializes settings. When initialization of setting is executed, existing each parameter setings are lost and return to default value. Be aware that settings does not return to the ex-factory settings speci/f_ied by /SET option. DEFAULT VALUE

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 6/7 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 92 (3.62) 45 (1 .77) 85 (3.35)11 (.43) 96 (3.78) 96 (3.78) 48 (1 .89) 103 (4.06) 10–M3 SCREW TERMINALS ■ TOP VIEW ■ FRONT VIEW ■ SIDE VIEW ■ REAR VIEW 1 2 3 4 5 6 7 8 9 10 6.4 (.25) 12 (.47) 4 (.16) MOUNTING REQUIREMENTS unit: mm + 0.8 – 0 + 0.6 – 0 min. 120 min. 75 Panel thickness: 1.6 to 8.0 mm

MODEL: 40DPT 40DPT SPECIFICATIONS ES-9537 Rev.7 Page 7/7 https://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM POWER U(+) V(–) COM HOLD Digital Computation 4 6 V U v uFuse Fuse VT LOAD SOURCE A/D Converter Display / Setting Specifications are subject to change without notice.