3RT2015-2AK61 SIEMENS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 8
Technical content
Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 110 V AC, 50 Hz 120 V, 60 Hz, 3-pole, Size S00, Spring-type terminal product brand name SIRIUS product designation Power contactor product type designation 3RT2 General technical data size of contactor S00 product extension
- function module for communication No
- auxiliary switch Yes power loss [W] for rated value of the current
- at AC in hot operating state 0.6 W
- at AC in hot operating state per pole 0.2 W
- without load current share typical 4.4 W insulation voltage
- of main circuit with degree of pollution 3 rated value 690 V
- of auxiliary circuit with degree of pollution 3 rated value 690 V surge voltage resistance
- of main circuit rated value 6 kV
- of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 400 V shock resistance at rectangular impulse
- at AC 6,7g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse
- at AC 10,5g / 5 ms, 6,6g / 10 ms mechanical service life (switching cycles)
- of contactor typical 30 000 000
- of the contactor with added electronically optimized auxiliary switch block typical 5 000 000
- of the contactor with added auxiliary switch block typical 10 000 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 10/01/2009 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature
- during operation -25 ... +60 °C
- during storage -55 ... +80 °C relative humidity minimum 10 % relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 % 3RT20152AK61 Page 1/8 7/4/2022 Subject to change without notice © Copyright Siemens
number of poles for main current circuit 3 number of NO contacts for main contacts 3 operating voltage
- at AC-3 rated value maximum 690 V
- at AC-3e rated value maximum 690 V operational current
- at AC-1 at 400 V at ambient temperature 40 °C rated value 18 A
- at AC-1 — up to 690 V at ambient temperature 40 °C rated value 18 A — up to 690 V at ambient temperature 60 °C rated value 16 A
- at AC-3 — at 400 V rated value 7 A — at 500 V rated value 6 A — at 690 V rated value 4.9 A
- at AC-3e — at 400 V rated value 7 A — at 500 V rated value 6 A — at 690 V rated value 4.9 A
- at AC-4 at 400 V rated value 6.5 A
- at AC-5a up to 690 V rated value 15.8 A
- at AC-5b up to 400 V rated value 5.8 A
- at AC-6a — up to 230 V for current peak value n=20 rated value 4 A — up to 400 V for current peak value n=20 rated value 4 A — up to 500 V for current peak value n=20 rated value 3.8 A — up to 690 V for current peak value n=20 rated value 3.6 A
- at AC-6a — up to 230 V for current peak value n=30 rated value 2.7 A — up to 400 V for current peak value n=30 rated value 2.7 A — up to 500 V for current peak value n=30 rated value 2.5 A — up to 690 V for current peak value n=30 rated value 2.4 A minimum cross-section in main circuit at maximum AC-1 rated value 2.5 mm² operational current for approx. 200000 operating cycles at AC-4
- at 400 V rated value 2.6 A
- at 690 V rated value 1.8 A operational current
- at 1 current path at DC-1 — at 24 V rated value 15 A — at 110 V rated value 1.5 A — at 220 V rated value 0.6 A — at 440 V rated value 0.42 A — at 600 V rated value 0.42 A
- with 2 current paths in series at DC-1 — at 24 V rated value 15 A — at 110 V rated value 8.4 A — at 220 V rated value 1.2 A — at 440 V rated value 0.6 A — at 600 V rated value 0.5 A
- with 3 current paths in series at DC-1 3RT20152AK61 Page 2/8 7/4/2022 Subject to change without notice © Copyright Siemens
— at 24 V rated value 15 A — at 110 V rated value 15 A — at 220 V rated value 15 A — at 440 V rated value 0.9 A — at 600 V rated value 0.7 A
- at 1 current path at DC-3 at DC-5 — at 24 V rated value 15 A — at 110 V rated value 0.1 A
- with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 15 A — at 110 V rated value 0.25 A
- with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 15 A — at 110 V rated value 15 A — at 220 V rated value 1.2 A — at 440 V rated value 0.14 A — at 600 V rated value 0.14 A operating power
- at AC-3 — at 230 V rated value 1.5 kW — at 400 V rated value 3 kW — at 500 V rated value 3 kW — at 690 V rated value 4 kW
- at AC-3e — at 230 V rated value 1.5 kW — at 400 V rated value 3 kW — at 500 V rated value 3 kW — at 690 V rated value 4 kW operating power for approx. 200000 operating cycles at AC-4
- at 400 V rated value 1.15 kW
- at 690 V rated value 1.15 kW operating apparent power at AC-6a
- up to 230 V for current peak value n=20 rated value 1.5 kVA
- up to 400 V for current peak value n=20 rated value 2.7 kVA
- up to 500 V for current peak value n=20 rated value 3.3 kVA
- up to 690 V for current peak value n=20 rated value 4.3 kVA operating apparent power at AC-6a
- up to 230 V for current peak value n=30 rated value 1 kVA
- up to 400 V for current peak value n=30 rated value 1.8 kVA
- up to 500 V for current peak value n=30 rated value 2.2 kVA
- up to 690 V for current peak value n=30 rated value 2.9 kVA short-time withstand current in cold operating state up to 40 °C
- limited to 1 s switching at zero current maximum 120 A; Use minimum cross-section acc. to AC-1 rated value
- limited to 5 s switching at zero current maximum 86 A; Use minimum cross-section acc. to AC-1 rated value
- limited to 10 s switching at zero current maximum 67 A; Use minimum cross-section acc. to AC-1 rated value
- limited to 30 s switching at zero current maximum 52 A; Use minimum cross-section acc. to AC-1 rated value
- limited to 60 s switching at zero current maximum 43 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency
- at AC 10 000 1/h operating frequency
- at AC-1 maximum 1 000 1/h
- at AC-2 maximum 750 1/h
- at AC-3 maximum 750 1/h
- at AC-3e maximum 750 1/h
- at AC-4 maximum 250 1/h Control circuit/ Control type of voltage of the control supply voltage AC control supply voltage at AC 3RT20152AK61 Page 3/8 7/4/2022 Subject to change without notice © Copyright Siemens
- at 50 Hz rated value 110 V
- at 60 Hz rated value 120 V operating range factor control supply voltage rated value of magnet coil at AC apparent pick-up power of magnet coil at AC
- at 50 Hz 26.4 VA
- at 60 Hz 26.4 VA inductive power factor with closing power of the coil
- at 50 Hz 0.81
- at 60 Hz 0.81 apparent holding power of magnet coil at AC
- at 50 Hz 4.4 VA
- at 60 Hz 4.4 VA inductive power factor with the holding power of the coil
- at 50 Hz 0.24
- at 60 Hz 0.24 closing delay
- at AC 9 ... 35 ms opening delay
- at AC 7 ... 13 ms arcing time 10 ... 15 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NO contacts for auxiliary contacts instantaneous contact operational current at AC-12 maximum 10 A operational current at AC-15
- at 230 V rated value 10 A
- at 400 V rated value 3 A
- at 500 V rated value 2 A
- at 690 V rated value 1 A operational current at DC-12
- at 24 V rated value 10 A
- at 48 V rated value 6 A
- at 60 V rated value 6 A
- at 110 V rated value 3 A
- at 125 V rated value 2 A
- at 220 V rated value 1 A
- at 600 V rated value 0.15 A operational current at DC-13
- at 24 V rated value 10 A
- at 48 V rated value 2 A
- at 60 V rated value 2 A
- at 110 V rated value 1 A
- at 125 V rated value 0.9 A
- at 220 V rated value 0.3 A
- at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor
- at 480 V rated value 4.8 A
- at 600 V rated value 6.1 A yielded mechanical performance [hp]
- for single-phase AC motor — at 110/120 V rated value 0.25 hp — at 230 V rated value 0.75 hp
- for 3-phase AC motor — at 200/208 V rated value 1.5 hp 3RT20152AK61 Page 4/8 7/4/2022 Subject to change without notice © Copyright Siemens
— at 220/230 V rated value 2 hp — at 460/480 V rated value 3 hp — at 575/600 V rated value 5 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link
- for short-circuit protection of the main circuit — with type of coordination 1 required gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA) — with type of assignment 2 required gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
- for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
- side-by-side mounting Yes height 70 mm width 45 mm depth 73 mm required spacing
- with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm
- for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm
- for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection
- for main current circuit spring-loaded terminals
- for auxiliary and control circuit spring-loaded terminals
- at contactor for auxiliary contacts Spring-type terminals
- of magnet coil Spring-type terminals type of connectable conductor cross-sections
- for main contacts — solid 2x (0.5 ... 4 mm²) — solid or stranded 2x (0,5 ... 4 mm²)
- at AWG cables for main contacts 2x (20 ... 12) connectable conductor cross-section for main contacts
- solid 0.5 ... 4 mm²
- stranded 0.5 ... 4 mm² connectable conductor cross-section for auxiliary contacts
- solid or stranded 0.5 ... 4 mm² 3RT20152AK61 Page 5/8 7/4/2022 Subject to change without notice © Copyright Siemens
type of connectable conductor cross-sections
- for auxiliary contacts — solid or stranded 2x (0,5 ... 4 mm²)
- at AWG cables for auxiliary contacts 2x (20 ... 12) AWG number as coded connectable conductor cross section
- for main contacts 20 ... 12
- for auxiliary contacts 20 ... 12 Safety related data product function
- mirror contact according to IEC 60947-4-1 Yes; with 3RH29 B10 value with high demand rate according to SN 31920 1 000 000 proportion of dangerous failures
- with low demand rate according to SN 31920 40 %
- with high demand rate according to SN 31920 73 % failure rate [FIT] with low demand rate according to SN 31920
100 FIT
T1 value for proof test interval or service life according to IEC 61508 20 y protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front suitability for use
- safety-related switching OFF Yes Certificates/ approvals General Product Approval Confirmation KC EMC Functional Safety/Safety of Machinery Declaration of Conformity Test Certificates Type Examination Certificate Type Test Certific- ates/Test Report Special Test Certific- ate Marine / Shipping Marine / Shipping other Confirmation Confirmation Further information 3RT20152AK61 Page 6/8 7/4/2022 Subject to change without notice © Copyright Siemens
Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2015-2AK61 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2015-2AK61 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2015-2AK61 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2015-2AK61&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2015-2AK61/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2015-2AK61&objecttype=14&gridview=view1 3RT20152AK61 Page 7/8 7/4/2022 Subject to change without notice © Copyright Siemens
last modified: 6/2/2022 3RT20152AK61 Page 8/8 7/4/2022 Subject to change without notice © Copyright Siemens