Ec hotel ® Mo del300/301 U ltrasonicN on-Contact TransmitterFor Level/ Volume /Open Channel Flow Softwareversion 1.x Instruction Manual and PartsList TABLE OFCONTENT S Agency Ap provals/ DE SCRIPTION The M odel 300/301 isa full-featured,powe rfulultrasonic system for me asurement of liquidlevel,volume, or open channel flow.Availableas an integralor remo te moun ted transmitter,this extreme ly versatilesystem is simple to installand calibrate. PRINCIPL E OFOPERATION The M odel300/301isa versatilesystem thatutilizesnon- contactultrasonic technologyto measure liquid levelsina varietyof applications.The system consistsof a transmitter and an ultrasonictransducer.Th e transducercontainsa piezoelectriccrystalthathas the ability to convertelectrical signalsgeneratedby thetransmitterintoultrasonicpulses. The unitoperatesby directing ultrasonicpulses,or sound waves,through the airtoward the liquidsurface.They are thenreflected offtheliquidsurfaceas an echo,and returned tothe transducer.The piezoelectriccrystalthenconvertsthe returned echo intoan electricalsignalwh ichisanalyzedby thetransmitter.Th e elapsedtimebetween thegenerationof the ultrasonicpulse and the return echo isproportionalto thedistancebetween thefaceofthetransducerand theliq - uidsurface. UNP ACKING Unpack the instrumentcarefully,m akingsureallcomponents have been remo ved from the packing material.Inspectall com ponents,and reportany dam age tothecarrierwithin24 hours.Check the contentsof the carton,making sure it agrees withthe packing slipand the purchase order.Verify thatthe m odelnum ber imprinted on thenameplate matches the num ber on the packing slipand the purchase order. R eportany discrepanciesto the factory.Check and record the serialnum ber forfuturereference when orderingparts. CA UTION: Pleaseread the entireinstallationsection carefullypriorto startinginstallation.
CONNE CTING CABLE PART NUMBER 037 -3176- Ca blelength infeet 10feet(3 m )m inimum ,500feet(152m) maximum length. Exam ple:12-footcablelength= 037-3176-012 Eac h M odel300/301UltrasonicTransmitterhas a nameplate w hich shows the mo del numb er of the unit.E ach model num beris coded to identifythe optionsinthatspecificunit. Listedbelow aredefinitionsofeach digitofthemodel num - ber.B y referringto thesecharts,the installercan determine exactlywhich optionsthe unitcontains. INTE GR AL MO UNT M ODE L 300TRANSMITT ER 3 0 0 -R -4 5 Transm ittertype 300 - Integralm ounttransm itter Transm itterhousing R - Aluminum diecastwithdual 1"N PT conduits Inputpow er 0 - 120V ac,50/60kHz 1 - 240V ac,50/60kHz 2 - 24 V dc Process outputsignal 1 - 4-20mADC 3 - R S-485 with Mo dbus 5 - 4-20mADC & RS -485 withM odb us Relay output 0 - N o relays C - Tw o 10-ampSPDT relaysw/ goldflashcontacts D - Four10-ampSPDT relays w/ goldflashcontacts Transducertype G - 2"N PT Kyn arwith3"insertionlength L - 2"N PT Kyn arwith10"insertion length RE MO TE MOUNT MODE L 301TRANSMIT TER 3 0 1 -R -4 0 0 Transm ittertype 301 - R emo temou nttransmitter Transm itterhousing R - Aluminum diecastwithdual 1"N PT conduits Inputpow er 0 - 120V ac,50/60kHz 1 - 240V ac,50/60kHz 2 - 24 V dc Output signal 1 - 4-20mADC 3 - R S-485 with Mo dbus 5 - 4-20mADC & RS -485 withM odb us Relay output 0 - N o relays C - Tw o 10-amp SPDT relaysw/ goldflashcontacts D - Four 10-amp S PDT relaysw/ goldflashcontacts TRA NS DUCE R PART NUMBER 3 8 4 - K - Transducer type 384 - 38 kHz Transducer Process connection 2 - 1"NPT 5 - 2"NPT Kynar transducer material Transducer housing 0 - No housing(35'ofcablepotted intothetransducer) 1 - Cast aluminum,NEM A 4X/7/9 housingwith 3/4"NPT singleconduit (cableorderedseparately) Y - 316S S ,NEM A 4X/7/9housingwith 3/4"NPT singleconduit(cable ordered separately) Transducer mounting bracket 0 - No m ountingbracket 3 - W allm ount bracketfor2"NPT process connectiontransducer 4 - Floorm ount bracketfor2"NPT process connectiontransducer Transducer insertionlength 003- 3"(76m m) length 010- 10"(254mm )length 1"N PT notavailablewithTransducerhousingcodes 1 orY Transducerm ountingbracketsnotavailablewith1"NPT transducers.
ME AS UREM ENT R AN GE CALC ULATIONS M EAS UREME NT RAN GE PARAM ETERS Ul trasonic non-contact devices are typicallyrated for a ma ximum range inidealconditions.Exp eriencehas shown that ma ximum range m ust be reduced for certainfactors. Although the maximu m range ratingissomewhat conser - vative,each application mu st be evaluated for specific conditions. T he operatingparameterslistedbelow can impact themax - imum range ofm easuremen t:
- S urface agitation
- Vap ors and steam (as measu redby temperature difference between liquidand air)
- Beam spread interference
- Transduceralignme nt
- Foam
- Dust
- Airmo vemen t
- Ambienttemp erature
- Pressure Sensor alignment Beam spread interference Beam spread interference Air movement DustVapors FoamSurface agitation HOW TOCA LCULAT E To estimatehow successfula particularapplicationmay be, usingthe charton page 4: 1. S electone conditionfrom each of the operating parametersthatbestdescribesyourapplication. 2. E nterthecorrespondingperformance multipliervalue in theapplicationcolumn. 3. M ultiplyallofthe selectedvaluestogether. 4. M ultiply step 3 by 30'(m aximum potentialrange); this yieldsa value thatis the m aximum allowable measurem entrange forthisapplication. E xample: The vesselisa closed-toptank,noninsulated,22-feettall. S urfaceagitation: E xpectslightagitationfrom fill line.Performance m ultiplier0.9. Vapor and steam: T he processtem peratureis +130°F ,slightvapor isexpected. Performan ce m ultiplier0.9. B eam interference: No interferenceexists. Performan ce m ultiplier1.0. Transduceralignment: T he transducerwillbe perpendi - culartothe liquidsurface. Performan ce m ultiplier1.0. Foam: No ne. Performan ce m ultiplier1.0. D ust: No ne.Performancemultiplier1.0. Airm ovem ent: No ne.Performancemultiplier1.0. Amb ienttemperature: 0to+120°F . Performan ce m ultiplier1.0. Pressure: Atm osphericpressure. Performan ce m ultiplier1.0. W illtheM odel300/301work forthisapplication? Ca lculation: M ultiplyallvaluesintheapplicationcolumn: 30feet(maxim um )= 24.3feet The calculationyields 24.3feetas the new maximum range. S incethe tankis22 feettall,thisapplicationwillgivesatis - factoryresults. NOTE : The performance m ultipliers provided are conser - vativeestimates.Since these factors are subjective,the valueshave been designed toprovide very high confidence of system success.Co ntact the factory ifthere are any questionsconcerningthe interpretationofany ofthese per - formance multipliers.
ME ASUR EME NT RANG E CALCUL ATIONS,cont. OperatingParameter Condition Perform ance Application Multiplier SURFACE AGITATION: Surfaceagitationor waves can degrade the Smooth,glasslikesurface 1.0 performance.Moderate agitationresultsinonlyslightdegradation Slightagitation,choppiness 0.9 ofperformance.The worstcase iswhen thesurfaceisa good Heavy agitation 0.8 reflector,but inthewrong direction.(See alsotransduceralignment.) Slightvortex(6°) 0.7 VAPORS AND STEAM: Vapors intheairspace,above theprocess, become apparent,and cause problems when theliquidprocess No condensation 1.0 temperatureiswellabove thetemperatureoftheairspace.The greaterthedifference,themore expected vapor problems.The problems resultfrom condensationor layeringinthesound path, both ofwhich attenuatethesound signal,degradingperformance. Littlecondensation 0.9 Avoidsteam ifpossible. To avoidtheseproblems,ensurethatthevesselisinsulatedso that vaporsarelesslikelytocondense.Ifa ventisused,be surethatthe Much condensation/ 0.8 vent,which iswhere condensationwillform,iswellaway from the foggy appearance transducer. BEAM SPREAD INTERFERENCE: Itisstronglyrecommended that No interference 1.0 nothingbe allowedwithinthetransducer’sbeam,excepttheliquid which isbeingmonitored.Often,thesignalfrom theliquidwillbe Agitatoratspeed lessthan60RPM 1.0 strong,compared tothesignalfrom othersources,such as ladder rungs,fillingprocessmaterial,supportstruts,etc.Forthatreason, Agitatoratspeed greaterthan60RPM Consult some applicationsmay providesatisfactoryresults,even with Factory interference.Interferencefrom agitatorbladesisonlyan intermittent interferencethatusuallyhas littleeffecton performance. Interferenceoutside4°,farfrom 0.8 Itisrecommended therebe no interferencewithinthe6°halfangle transducer(inbottom thirdofrange) ofthetransducerbeam. Ifinterferenceisunavoidable,make theinter- ferenceas faras possiblefrom thetransducerso thattherealsignal Interferenceoutside4°,nearto 0.5 atthelongestdistanceisstrongerthantheinterferencesignal. transducer(intop thirdofrange) TRANSDUCER ALIGNMENT: Optimum performanceisobtainedwhen Beam perpendiculartoliquidsurface 1.0 thetransducerisperfectlyaligned.Iftheprocessisnot perpendicular tothesound beam,thesound willnot reflectproperlyback tothe transducer.The effectissignificant. Beam 4°offfrom perpendicular 0.5 FOAM: Even smallthicknessesoffoam can attenuatetheultrasound No foam 1.0 and renderthesystem inoperative.Ifpossible,moving thetransducer Lightfroth,lessthan0.25"thick 0.8 toan areainthetankwhere thereislessfoam willimprove the performance.Thick,heavy-densityfoams can sometimes produce Lightfoam,lessthan0.5"thick 0.5 a reflectionfrom thetop ofthefoam.The multipliersshown atright Lightfoam,more than1"thick 0.1 aregeneralguidelines.Forfurtherassistanceconsultthefactory. DUST: Dust attenuatesthesound and resultsinpoor performance. No dust 1.0 Even barelyperceptiblehaze intheaircan cause significant Haze,barelyperceptible 0.7 attenuation. Slightdust 0.4 Heavy dust 0.1 AIR MOVEMENT: The movement ofair,as possibleinan open top No airmovement 1.0 vessel,can createa layerfrom which thesound willreflect.This will Open vessel,but transducerbelow rim 0.8 be most noticeableinapplicationswhere vaporsor steam tend to form. Open airmovement insound path 0.7 AMBIENT TEMPERATURE: The ambient temperaturecan have a -20°to+140°F(-29°to+50°C) 1.0 significanteffecton thesound and on thetransducer’scapabilityto -40°to-20°F(-40°to-29°C) 0.9 transmitand receivesound.The most noticeableeffecton the transducerisatthetemperatureextremes. +140°to+160°F(+50to+70°C) 0.9 PRESSURE: Sound requiresairmoleculestobe abletotravel.Sound -10to+50psig(0.689to+3.45Bar) 1.0 willnot travelina vacuum. Likewise,higherpressureswillallow thesound tocontinuewithoutdecay,which can cause problems with Pressuresoutsideabove rating Consult multipleechoes. Factory Multiplyallvaluestogetherintheapplicationcolumn Maximum PotentialRange forModel 300/301 X 30' Maximum allowablemeasurement range forthisapplication
E LE CT ROSTATIC DISCHARGE (ESD)HANDLING PROC EDU RE M agnetrol electronic instruments are ma nufactured to the highestqualitystandards.T hese instrumen tsutilizeelectron - iccomp onents wh ich ma y be dam aged by staticelectricity presentin mo stwork environments.T he followingstepsare recomm ended to reduce the riskofcompon entfailuredue to electrostaticdischarge: 1. Sh ip and store circuitboards inanti-staticbags.Ifan anti-static bag isnotavailable,wrap boardinaluminum foil.Do notplaceboardson foam packingm aterials. 2. Use a grounding wriststrapwhen installingand remov - ingcircuitboards.A grounded workstationisalsorec - om mend ed. 3. Han dleprintedcircuitboards onlyby theedges.Do not touch com ponentsor connectorpins. 4. Ensure thatallelectricalconnections are completely m ad e and none are partial or floating.Ground all equipm enttoa good,earthground. TRAN SDU CER MO UNTING cont. Distance from 12°Beam M inimum Distance Transducer Diameter (feet) from W allor Face (feet) Obstruction(inches) 3' 0.6' 4" 6' 1.3' 8" 9' 1.9' 11" 12' 2.5' 15" 15' 3.2' 19" 18' 3.8' 23" 21' 4.4' 26" 24' 5.0' 30" 27' 5.7' 34" 30' 6.3' 38" Table1 UltrasonicBeam Angle CAUT ION:HA ND TIGHTEN ONLY . Do NO T use a pipe wrench or other toolswhen tighteningthe transducer.Do NO T tighten by holding onto the transducer housing. Avo idexcessivetwisting ofthe transducercable. CA UTION: D o NOT installtransducers inthe centerof domed rooftanks.Locate transducers 1'to 3'off-center to m inimize false/multipleechoes being reflectedoffthe domed roof. ULTRA SONIC BE AM ANGLE T he transducer must be m ounted such that the beam does nottouch the sidewallorobstructions(ladders,filllines,sub - me rged pump s,etc.)between the transducer face and the liquid surface.Th e ultrasonicpulseisemittedwitha beam spread of 12° (6°radius) from the face of the transducer. O bjects that extend into the ultrasonicbeam can produce falseechoes thatmay giveerroneous levelreadings. Table 1can be used todeterminehow faraway from thewall, ladder,subme rgedpum p,orotherobstruction,thetransduc - er m ust be mo unted to avoid producing falseechoes. Gen erally speaking,the transducer shouldbe mounted one footaw ay forevery10feetofheight. TRAN SM ITTER MOUNTING Ifthe unitissupplied as an integralMo del300,pleaseskip to thenextsectionw hichcoversproperESD handlingpro - cedures.T hissection covers proper transmittermounting ifthe unitisa Mode l301 remo tetransmitter. TR ANSM ITTER MO UNTING LOCAT ION T he following guidelines should be taken into considera - tion w hen selecting the m ounting locationforthe remote mo unted Mo del301transm itter: 1. Kee p the transm itter away from potentialsources of electrom agneticnoise that m ay interfere with the per - formanc e of the unit. TRA NS M ITTE R MOUNTING LOCAT IONcont . 2. Avoid locations that are exposed to intense direct sun - light.In locations w here intense sunlight isa concern, use a sunshade over the unit. 3. Also avoid locations that are subjected to flooding or excessivevibration or shock. NOTE : A sw itch or circuitbreaker shall be installed in close proximity to equipmen t and w ithin easy reach of operator.Itshallbe ma rked as the disconnecting device forthe equipme nt. CAUT ION: The instrument isratedper IEC 1010 foruse ininstallation CategoryII,PollutionDe gree 2.
NOTE: Do NOT attempttooperate thisunitatvoltagesother than as ordered from theM odelIdentificationas itwilldam - age the unit. NOTE: Properrouting of the wires intothe 300/301 iscriti - calto unitoperation.T he power and relaywiring shouldbe brought into the 300/301through the1"NPT condu itopen - ing at the back of the unitnext to the transformer.Allother w iring (transducer,4-20m A,and RS-485)should be routed through the 1"N PT conduitopeninginthe front ofthe unit. No cables shouldbe routed through the bottom centerentry inthe base ofremot e-mounted M odel301units. TRA NS M ITTE R POWER WIRING 1. E nsurethatpower sourceisturned offfrom unit. 2. Pullthe pow er supp ly wires through the cond uit connection. 3. Connect thepositive(hot)supplywireto theL1 on ter - minalblockTB 1. 4. Connect the negative(neutral)supplywireto the L2/N on terminalbock TB1. 5. Connect the ground wire to the green screw in the housingbase. Table2 W iringColors By Country/Continent CAUTION: Thisinstrument isgrounded through green head screw contactinthe base.The power input m ust include a ground wireconnec tedto a good earthground . Failure to ground the instrumen tm ay allowa shock haz - ard to exist! WIRIN G U.S. Europe U.K. Line1 (HI) Black Blue Brown Line2 Neutral White Black Blue Ground Green/Yellow Green/Yellow Green/Yellow Figure 4 Power SupplyBoard Wiring NC CO NO Relay2 (TB3) Relay1 (TB2) NO NC CO L1 (+) L2/N (–) Inputpower (TB1) NC NO CO NC NO CO Relay4 (TB4) Relay3 (TB5) Not used
WITHOUT A TRANSDUCE R HOUSING Group 1 1. C onnectthe orange withwh ite stripe wireto the termi - nalm arked X1 atTB6. 2. C onnect the shieldwire to the terminalmarked GN D atTB 6. 3. C onnectthe white withorange stripewireto thetermi - nalm arked X2 atTB6. Group 2 1. C onnect the wh ite withblue stripe wireof the twisted pairto terminallabeledpositive(+)atTB6. 2. C onnect the blue w ith whitestripe wireof the twisted pairto terminallabelednegative (-)atTB6. 3. Proceed totheappropriatesectionforwiringoptions. NOTE: B oth groups ofwirem ustbe connected. WITH A TRA NSDUCER HOUSING Iftransducer housing isprovided,use the connecting cable ordered with the remote transducer housing.Connect the transducer cable between the terminal block in the trans - ducer housing to TB6 inthe transmitter.Be sure to connect w ires to appropriate terminals.Referto Figures5 and 6on page 8. Group 1 1. C onnect the orange with white stripewire from the transducer housing terminalm arked X1 to the terminal ma rked X1 atT B6 inthe transm itter. 2. C onnect the shieldfrom the transducer housingtermi - nalmarked SHL D to the terminalatTB6 in the trans - mitter. 3. C onnect the wh itew ith orange stripewire from the transducer housing terminalm arked X2 to the terminal ma rked X2 atT B6 inthe transm itter. Group 2 1. C onnect the wh ite withblue stripe wireof the twisted pairfrom the transducerhousingterminalma rked posi - tive (+)to the terminallabeledpositive(+)atTB6. 2. C onnect the blue w ith whitestripe wireof the twisted pairfrom the transducer housing terminalm arked neg - ative(-)to the terminallabelednegative (-)atTB6. 3. Proceed totheappropriatesectionforwiringoptions. NOTE: Inhigh humidityapplications,itisrecommend ed that the w iring within the remo te transducer housing be com - pletely imm ersedinan insulatingcompoun d (3M #4441Gella Re-enterableEnc apsulatingC omp ound or equivalent). CONT ROL REL AY WIRING T he Mo del300/301unitissuppliedwithfourrelaysthatcan operateas normal,independentcontactclosures orbe used as dedicated relays as follows: R elay 1 Norma l/Fault/Lead-Lag R elay 2 Norma l/Lea d-Lag R elay 3 Norma l/Lea d-Lag R elay 4 Norma l/Lea d-Lag Relay connectionsaresuppliedon the main terminalboard. RefertoFigure4 on page 7. 1. Connect two-wireleadsto the desiredrelayconnection forrelays1 –4.Connect one wire to theterminallabeled COM and the other totheterminalforthedesiredcon - tactfunction,NC fornorm allyclosed or NO fornormal - ly open.R epeat thisstepforeach relay. 2. R efertoR elaySettingsintheI/O Configurationsection on page 22forinformationon configuringtherelays. 3. Proceed to wire any rem aining optionsthe unitmay have. NOTE : Ifthe device to be operated by the relayhas an inductiveload,a separatepower supplyshouldbe used for the M odel300/301transmitter. OUTPUT SIGNA L WIRING 4–20m A DC Output A shieldedtwistedpairshouldbe used forthe 4-20mA out - put.The + and – connectionsarem ade attheterminalblock to therightofthe 16-buttonkeypad as shown inFigure5 on page 8.T he shieldisconnected witha femaledisconnectto a connectorlocatedinthe housingbase,justbelow thesen - sor connections.The loop is opticallyisolated,has non- grounded outputs,and can drivea 1000Ω load. NOTE : Th e outputmay be eitheran activeor passive4–20 m A.Ifpassivem ode,customer m ust provideloop power. Figure5 on page 8 shows theActive/Passivemode switch. 1. Cut approximately8"ofinsulationoffthetwistedshield - ed cable. 2. C ut the shield wiredown justshortenough to crimp a female disconnect(S ta-Kon ® )connector.C rim p thecon - nectoron and push thisoverthemale connectorlocat - ed atthebase ofthehousingas shown inFigure7. 3. The + and – wires shouldthen be twistedtogetherand runup tothe4-20mA terminalblocklocated totheright ofthe16-buttonkeypad as shown inFigure7. 4. Connect thepositive(+)shieldedtwistedpairwiretothe + locationon theterminalblock. 5. Connect the negative(–)shielded twisted pairwireto the – locationon the terminalblock. NOTE : The shieldshouldbe connected to an earthground atonlyone location. W IRING cont. A B 4-20 mA 4 5 6 1 2 3 0. DEL ENT Shield connection (Cut to shortest possible length.) Figure 7 4-20mA W iring
W IRING cont. OUTPUT SIGNA L WIRING cont. RS -485 Output A shielded twisted pairshouldbe used forthe R S-485wiring. T he “A” and “B” connectionsarem ade attheterminalblock to therightofthe 16-buttonkeypad as shown in Figure5 on page 8.T he shieldisconnected witha femaledisconnectto a connectorlocatedinthehousingbase,justbelow thesen - sorconnections. 1. C utapproximately8"ofinsulationoffthe twistedshield - ed cable. 2. C ut the shield wiredow n justshortenough to crimp a female disconnect(S ta-Kon ® )connector.C rimp thecon - nectoron and push thisoverthemale connectorlocat - ed atthe base ofthe housingas shown in Figure7. NOTE: Ifboth the 4-20 m A and the RS-485 outputs are being used,twistthe shields togetherand follow Step 2 above. 3. Th e “A” and “B” w ires shouldthen be twistedtogether and run up to the RS -485 term inalblock located to the rightofthe 16-button keypad as show n inFigure 7. 4. C onnectthe “A” wirefrom thecontrolroom converterto the terminalmarked “A” on the R S -485terminalblock located to the right of the 16-buttonkeypad as shown in Figure 5. 5. Connect the “B” wirefrom thecontrolroom converterto the terminalm arked “B” on the RS-485 terminalblock locatedto the rightof the 16-buttonkeypad as shown inFigure5. 6. Ifconnectingm ultipleM odel 300/301unitsina daisy- chain configuration,be sure to connect the wiringin paralleland have the ending unitwiththe termination resistorjumpered.Jum pers should be removed from other unitsin the daisy chain.T he threetermination jum per pins (JP1)arelocated behind the blackprotec - tivecover and justbelow the RS-485 terminalblock. The lastunitinthe daisychainshould have a jumper between pins1 and 2.Allotherunitsinthe daisychain should eitherhave a jumper between pins 2 and 3,or have no jum per atall. NOTE : Polarityam ong unitsinloop must be observed. NOTE : Ifconnectingseveralunits,note thecolorwireused forA and B and ensure that the same designatedcoloris used foreach ofthe units.
KE Y FUNCT IONS FOR ENT ERING INPUT NOTE: W hen a line ends with an up ordown arrow,thatline ma y be scrolledup or down. Wh en the sym bol isdisplayedon the top line,push ENT to program thisselection,or press to proceed to the nextselection. Wh en the sym bol isdisplayedon the bottom line,push to change theselection;thenpush ENT to accept. Wh en the symb ol isdisplayedon the bottom line,enter the value,then push ENT toaccept. NOTE: Pressing DEL willback you outoftheconfiguration me nu and return you torun m ode. NOTE: Ifa key isnot pressed for5 minutes,the display returns tothe run m ode. OPE RATOR KE YPAD Allunitconfigurationinstructionsinthismanual willappear on the instrumentdisplay.The following keys areused: UP arrow: S crolltothepreviousmen u item. D OW N arrow: S crolltothenextm enu item. ENTER : Enter thenextm enu levelor confirm informationofthecurrentm enu item. D E LETE : To exitor back outofthecurrentmenu level,or deletean entry. Num ericinputofdata. D ecimalpoint. Forentering taglinedata (see page 26). DEL PASSW ORD A password protectionsystem restrictsaccess toportionsof the m enu which affectthe unit’soperationand configuration. The password willbe requested wh enever programming changes are requested in a m enu.Once the password is enteredina specificm enu,itisnotrequestedagainuntilyou exitthat m enu and go into a different menu to make changes. The password can be changed to any number between 1 and 32767.T his procedure is described under the ADV CONFIG m enu on page 25. CAUT ION: The Model 300/301 isshipped from the fac - tory with the password 300. Ifthe password is m isplaced orforgotten,pleaseconsultthe factory for assistance. E N T 0-9 GE NE RA L CONFIGURAT IONINSTRUCT IONS T he M odel300/301ultrasonicnon-contacttransmittercon - tains a microprocessor-based operator interface which allow s foreasy configuration oflevel,flow,orvolume control applications.Allcalibration parametersfortheseapplications are entered viaa keypad located on the front of the trans - mitter. T he primary structure ofthesoftwareisbroken down intosix ma inmen u groups as follows: Mea sured Values To view m easured values System Co nfig Firsttime configuration (Essen tialprogramm ingdata) I/OCo nfig Configureallinput/output functions Advanced Co nfig Additionalvalues thataffectthe performance oftheunit Diagnostics Test functions and unitperform - ance data Ru n m ode Norm aldisplay.T he unitwill defaultto thisdisplayafter approxim atelyfivem inuteswith - out any key stroke. SOFTW ARE CONF IGURATION
M ODE L 300/301PRE-C ONFIGUR ATION W ORKSHEET T his page isdesigned to be a worksheet where allthe sys - tem configurationdatacan be writtendown priorto entering them into the unit.Th e system configurationismuch faster once allthe data isknown. T hispage can then be used for futurereference afterthe unithas been configured. S ystem configuration oftheM odel300/301iseasilyaccom - plishedby inputtingthe followingvaluesas they relateto yourspecificapplication: Lev elApplications Volume & Level App lications Flow & L evelApplications Levelunits: Levelunits: Levelunits: R ange: Volume units: Flowunits: Span : Vessel type: Primaryflowelement: Vessel dimension: Referencedistance: R ange: Maximum head: S pan: Low flowcutoff: Units: A selectionforlevelunitsisrequiredregardlessof whether levelwillbe the primary measurement. This is because theM odel300/301calculatesvolume and flowfrom the levelthatism easured inthe vessel,flume,or weir.One of the four levelunitsshown on page 13 must be selected. Volum e or flowunitsmu stalsobe selectediftheLevelOnly m ode isnotbeingused. Range: R ange isdefinedas the distancefromthefaceofthe ultrasonictransducer to the bottom of the levelspan.This usuallyisthedistance from the faceofthetransducer tothe bottom of the vessel.T he m aximum range forthe Model Span: S pan isthe distancefrom the bottom of the level m easurement to the top.The m aximum span isthe range m inusthe dead band (18")ofthe ultrasonictransducer.The m aximum span forthe 300/301 is28.5'(8.7m). VesselType: The Volum e & Levelmod e willrequireone of the nine vesseltypes shown on page 13 to be selected. Equations to calculatevolume from levelare storedin the software.Iftheapplication has a vesseltype thatisnot list - ed,thena custom tablewillneed tobe builtusingeithera lin - earor splinecurve. VesselDimen sions: Dim ensionaldata willvary depending on which vesseltype isselected.See pages 18&19 formore information. Primary Flow E lement: The Flow& Levelmode willrequire selectionof one of the m any flow elements to be selected thatareshown on page 14.Eq uationstocalculateflowfrom levelarestored inthe software.Iftheapplication has a flow elementthatisnotlisted,then a custom tablewillneed tobe builtusingeithera linearor splinecurve. Reference Distance: The referencedistanceisthe open channelflow equivalentto therange.See above. M aximum Head: M aximum head isthe open channel flow equivalenttothespan.See above. Low Flow Cutoff:The low flowcutoffwillforcea zeroflow valuewhen thelevelisator below thispoint. Model 300 Air Liquid Dead zone Range Span
SOFTWAR E CONFIG URATION cont. GE NE RA L PROGRAMM ING M ENUS Follow ing isan outline ofthe generalmenu structure used in the M odel300.E ven though allfeaturesare shown ,certain features willonlyaffectspecificmo dels.Forexample,the relay men u can be accessed inallm odels,but changes will only affectthe m odelswithrelays. Use theUP and D OWN arrowkeys toscrollthroughany por - tion of the men u;use the ENT key to make a selection.A detaileddescriptionof each portionof the menu followson page 15. M E AS URE D VAL UES Volume (Volume mode only) Flow(Flowmode only) Level Distance Loop Temperature Previousmenu LevelUnits Inches Feet Centimeters Meters Volume & Level LevelOnly Mode Setup SY STEM CONF IG Manual Set Auto Set PreviousMenu Manual Set Auto Set PreviousMenu Cubic Feet Cubic Inches Gallons Milliliters Liters Rectangular Horizontal/Flat Horizontal/Elliptical Horizontal/Spherical Spherical Vertical/Flat Vertical/Elliptical Vertical/Spherical Vertical/Conical Custom Table Manual Set Auto Set PreviousMenu NOTE: Us e keys to move up or down in the menu tree.Use th e key to accept a valueor to move rightin the menu tree.Us e to deletea keystroke or to move leftinthe menu tree. DE L Range Setting Span Setting Volume Units Vessel Type Table Type (Custom table only) Linear Spline Table Type (Custom tableonly) Linear Spline Range Setting Span Setting PreviousMenu Flow& Level Data Entry (Custom tableonly) Custom Table Data Entry (Custom tableonly) Manual Set Auto Set PreviousMenu Cubic Feet/Second Cubic Feet/Minute Cubic Feet/Hour Gallons/Minute Gallons/Hour MillionGallons/Day Liters/Second Liters/Minute Liters/Hour Refertoliston page 14 FlowUnits FlowElement Maximum Head Low FlowCutoff Maximum Flow Reference Distance Manual Set Auto Set PreviousMenu Manual Set Auto Set PreviousMenu PreviousMenu ENT
SOFTWAR E CONFIG URATION cont. GE NE RA L PROGRAMM ING M ENUS cont. I/OCONF IG DNRG<Set Point DNRG>Set Point Level Volume (Volume & Levelmode only) Flow(Flow& Level mode only) Level Volume (Volume & Levelmode only) Flow(Flow& Level mode only) Offon Fault Hold on Fault Odd Even None Off 1–2 1–2–3 1–2–3–4 2–3 2–3–4 22mA 3.5mA Hold Address (0-247) PreviousMenu Parity Baud Rate Enable/Disable 4 mA Point 20mA Point FaultMode PreviousMenu Relay Settings Calibrate Gain Limit(Range 0–32) StartingGa in (0– Gain limit) Echo Loss Delay (1–150) SelectRelay FaultRelay #1(#1only) Enable/Disable Controlledby (Volume & Flowmodes only) Relay On Point Relay OffPoint Relay Action Relay On Delay (0–255) Relay OffDelay (0–255) FaultMode PreviousMenu Lead-Lag Mode 4–20mA Settings Comm PortSetup Enable/Disable(#1only) PreviousMenu ADVA NCED CONFIG DefaultDisplay AdjustLoop Points Enter Tag Line PreviousMenu PreviousMenu Test Relays SelectRelay (1–4) Gain/% Signal DIAGNO STICS Enter Loop Value (3.5–22) Test 4–20Output Enter Old Password Enter New Password Enter New Again PreviousMenu 3.5mA offset Change Tag View Version PreviousMenu Damping (1–60) 1200 2400 4800 9600 Change Password From page 13 Flow Element (flowmode only) PalmerBowlus 10" 12" 15" 18" 21" 24" 27" 30" H-Flume 12" 18" 24" 30" 36" 54" V-notch 22.5° 30° 45° 60° 90° 120° Parshall 12" 18" 24" 36" 48" 60" 72" 96" 120" 144" Rectangular w/ End Contractions Rectangular w/o End Contractions Cipoletti Manning Custom Table Controlledby (Volume & Flow modes only) Level Loop Flow }w /#1 as faultrelay 22mA offset
System ConfigurationMenu (LevelOnly) Display Keystroke Comment and/orAdditionalKeystrokes Magnetrol Int’l PressENT At startup,theunitisintherun mode displayingMagnetrol Int’l.PressingENT xxxx units allowsyou toenterthemain menu. Measured Values Press Allowsyou toentertheSystem Config menu. ENT toSelect System Config PressENT Enters thefirstdisplay(LevelUnits)ofSystem Config.menu. LevelUnits IfinchesarethedesiredLevelUnits press tocontinuetothenextitem.To Inches PressENT or change units,pressENT and toselectFeet,Centimeters,orMeters.PressENT toselectdesiredLevelUnits. Enter Password Enter ValidPassword Enteringa validpassword and pressingENT setsyourunitselectionand (ifunitschanged) (factorydefaultis300) continueson tothenextitem. Mode Setup Press tocontinuetothenextitem.This sectioncoversa LevelOnly config- LevelOnly Press uration.Turn topage 17ifa Volume & Levelconfigurationisdesired,or page 20 forFlow& Level. SOFTWAR E CONFIG URATION cont. T he M easuredValues Menu can be accessed by pressing the E NT key from the run m ode.You may scrollthough the me asured values by using the up and down arrows.Th e items displayed in the Me asured Values Me nu willdiffer depending on whether Leve lOnly,Vol& Level, or Flow & L evel has been selected in the System Config section describedlaterinthism anual. Measured ValuesMenu Display Keystroke Comments or AdditionalKeystrokes Magnetrol Int’l PressENT Enters theMeasured Values Menu. xxxx units Measured Values PressENT Displaysthefirstitem(Level)intheMeasured Values Menu. Level Press Indicatesthelevelofmaterialinthevessel.Pressing allowsyou tocontinue xxxx units tothenextmenu item. Distance Press Indicatesthedistancefrom thefaceofthetransducertothetarget.Pressing xxxx units allowsyou tocontinuetothenextmenu item. Loop Press Indicatesthemilliampcurrentloopoutput.Pressing allowsyou tocontinueto xxxx thenextmenu item. Temperature Press Indicatestheairtemperatureatthetransducer.The temperatureunitsarein° For° C depending upon whether Englishor metricunitsoflevelarechosen.Pressingxxxx F allowsyou tocontinuetothenextmenu item. PreviousMenu PressENT , ,or DEL Pressing willcycleback totheLeveldisplay,or pressENT or DEL tocontinue ENT toselect tothenextconfigurationitem. T his System Con figurationm enu isused for basicsetup of the unit.R eferto pages 13 and 14forthe complete menu layout.T he Mo del300/301iscapableofbeingconfigured in three different mo des of operation— Le velOnly ,Volume & Lev el ,or Flow & Lev el .T he System ConfigurationMenu is forselecting the m easuremen tunitsand calibratingthe sys - tem tom easureLevel Only (refertopage 15-16),Volume & Level (page 17),or Flow & Le vel (page 20). The following tableisa step-by-stepprocedureforusingthe Level Only m enu.Itisassum ed thatyou arestartingfrom the R UN m ode. Con tinuedon page 16 ME AS URE D VALUE S ME NU SYSTEM C ONFIGURATION M EN U— LEVEL ONLY
SOFTWAR E CONFIG URATION cont. 18" (457 mm) Range Span NO YES Figure 9 Figure10 Maximum span should never be great enough to allow level measurement inside the nozzle, where theultrasonictransduceris mounted. SYST EM CONFIG URAT IONM E N U— L EVEL ONLY cont. System ConfigurationMenu (LevelOnly)cont. Display Keystroke Comment and/orAdditionalKeystrokes Range Setting PressENT or PressENT tochange therange setting.Ifsettingiscorrectpress xxxx units tocontinuetoSpan Settings.RefertoFigure9. NOTE: Itisrecommended touse Manual Set (as opposed toAuto Set)when changing therange or span settings. PressENT tomanuallysettherangesetting.An willappear inthebottom line Manual Set PressENT or ofthedisplay.This allowsyou tochange therange value.Measure the xxxx units distancefrom thefaceofthetransducertothemaximum distancetobe measured.Enter valueand pressENT .IfAuto Set ispreferredpress . The liquidsurfacemust be atthemaximum distancetobe measured. Auto Set (Ifchosen) PressENT or Check tosee thatthedistancebeingdisplayediscorrect.When you pressthe xxxx units ENT key,thatdistancewillbe setas yourrange and theprogram willcontinue on tothenextselection.To continuewithoutmaking changes press . NOTE: The span valueisautomaticallysetONLY when theenteredrange valuehas decreased from itspreviousvalue. Span Setting Value shown willbe 18incheslessthantherange setting.This isthemaximum xxxx units PressENT or span valueavailable.Ifyou want toreducethespan,pressENT .RefertoFigures 9 and 10.Ifthepresentsettingiscorrectpress tocontinuetoPreviousMenu. Manual Set PressENT tomanuallysetthespan setting.Measure thedistancefrom the xxxx units PressENT or maximum range thatwas settothehighestpointtobe measured.Enter value and pressENT .IfAuto Set ispreferredpress . The liquidsurfacemust be atthehighestleveltobe measured. Auto Set (Ifchosen) PressENT or Check tosee thatthelevelbeingdisplayediscorrect.When you presstheENT xxxx units key,thatmeasurement willbe setas yourspan and theprogram willcontinueon tothenextselection.To continuewithoutchanges press . PreviousMenu PressENT PressingtheENT key willsetallvaluesand returntoSystem Config.PressDEL ENT toselect toreturntotherun mode.
T his me nu isused toselectthe m easurement unitsand con - figurethe system tom easureVolume & Leve l. Refertopage 15 for L evelOnly applications or page 20forFlow & Level applications. Followingisa step-by-stepprocedure forusing the Volume & Levelm enu.Itisassum ed thatyou are startingfrom the R UN m ode. SOFTWAR E CONFIG URATION cont. SYSTE M CONFIGURATION MEN U — VOLUME AND LEVEL System ConfigurationMenu (Volumeand Level) Display Keystroke Comment and/orAdditionalKeystrokes Magnetrol Int’l PressENT At startup,theunitisintherun mode displayingMagnetrol Int’l.PressingENT xxxx units allowsyou toenterthemain menu. Measured Values Press Allowsyou toentertheSystem Config menu. ENT toSelect System Config PressENT Enters thefirstdisplay(LevelUnits)ofSystem Config menu. LevelUnits IfinchesarethedesiredLevelUnits press tocontinuetothenextitem.To Inches PressENT or change units,pressENT and toselectFeet,Centimeters,orMeters.PressENT toselectdesiredLevelUnits. Enter Password Enter ValidPassword Enteringa validpassword and pressingENT setsyourunitselectionand (ifunitschanged) (factorydefaultis300) continueson tothenextitem. Mode Setup PressENT Then press thenENT tochange toVolume and Levelmode. LevelOnly Volume Units IfcubicfeetarethedesiredVolume Units,press tocontinuetothenextitem. Cubic Feet PressENT or To change units,pressENT and toselectcubicinches,gallons,milliliters,or liters.PressENT toselectdesiredVolume Units. PressENT , ,thenENT tochange presentsetting.You may selectRectangular, Vessel Type PressENT or Horiz/Flat,Horiz/Ellip,Horiz/Sphere,Spherical,Verti/Flat,Verti/Ellip,Verti/Sphere, Rectangular Verti/Conicalor Custom Table (RefertoFigure12forCustom Table).Ifthe presentsettingiscorrect(Rectangular),pressENT, inputvesseldimensions,and thenpress tocontinuetonextselection. Radius= The valuesrequestedmay varydepending on thetypeofvesselselected.Refer xxxx units Enter valueand pressENT tovesseldrawingforproperdimensions. (Vessel Dependent) Width= The valuesrequestedmay varydepending on thetypeofvesselselected.Refer xxxx units Enter valueand pressENT tovesseldrawingforproperdimensions. (Vessel Dependent) Length= The valuesrequestedmay varydepending on thetypeofvesselselected.Refer xxxx units Enter valueand pressENT tovesseldrawingforproperdimensions. (Vessel Dependent) Range Setting PressENT or PressENT tochange therange setting.Ifsettingiscorrect,press tocontinue xxxx units toSpan Settings. NOTE: Itisrecommended touse Manual Set (as opposed toAuto Set)when changing therange or span settings. PressENT tomanuallysettherangesetting.An willappear inthebottom line Manual Set PressENT or ofthedisplay.This allowsyou tochange therange value.Measure thedistance xxxx units from thefaceofthetransducertothemaximum distancetobe measured.Enter valueand pressENT .IfAuto Set ispreferredpress . The liquidsurfacemust be atthemaximum distancetobe measured.Check to Auto Set (Ifchosen) PressENT or see thatthedistancebeingdisplayediscorrect.When you presstheENT key, xxxx units thatdistancewillbe setas yourrange and theprogram willcontinueon tothe nextselection.To continuewithoutmaking changes press . NOTE: The span valueisautomaticallysetONLY when theenteredrange valuehas decreased from itspreviousvalue. Span Setting Value shown willbe 18incheslessthantherange setting.This isthemaximum xxxx units PressENT or span valueavailable.To reduce thespan pressENT .Ifthepresentsettingis correctpress tocontinuetoPreviousMenu. Manual Set PressENT tomanuallysetthespan setting.Measure thedistancefrom the xxxx units PressENT or maximum range thatwas settothehighestpointtobe measured.Enter value and pressENT .IfAuto Set ispreferredpress . The liquidsurfacemust be atthehighestleveltobe measured.Check tosee Auto Set (Ifchosen) PressENT or thatthelevelbeingdisplayediscorrect.When you presstheENT key,that xxxx units measurement willbe setas yourspan and theprogram willcontinueon tothe nextselection.To continuewithoutchanges press . PreviousMenu PressENT PressingtheENT key willsetallvaluesand returntoSystem Config.PressDEL ENT toselect toreturntotherun mode.
SOFTWAR E CONFIG URATION cont. Rad SideView VERTICAL/ELLIPTICAL Rad SideView VERTICAL/SPHERICAL
Th ismenu is used toselectthem easurementunitsand con - figurethesystem tomeasure Flow & Level .Refertopage 15 for Le velOnly applications or page 17 forVolume & Lev el applications. Followingisa step-by-stepprocedureforusingthe Flow & Level m enu.Itisassum ed thatyou arestartingfrom theRUN mod e. SOFTW ARE CONFIGURATION cont. SYST EM CONFIG URAT IONM E N U— FLOW AND LEVEL System ConfigurationMenu (Flowand Level) Display Keystroke Comment and/orAdditionalKeystrokes Magnetrol Int’l PressENT At startup,theunitisintherun mode displayingMagnetrol Int’l.PressingENT xxxx units allowsyou toenterthemain menu. Measured Values Press Allowsyou toentertheSystem Config menu. ENT toSelect System Config PressENT Enters thefirstdisplay(LevelUnits)ofSystem Config menu. LevelUnits IfinchesarethedesiredLevelUnits press tocontinuetothenextitem.To Inches PressENT or change units,pressENT and toselectFeet,Centimeters,orMeters.PressENT toselectdesiredLevelUnits. Enter Password Enter ValidPassword Enteringa validpassword and pressingENT setsyourunitselectionand (ifunitschanged) (factorydefaultis300) continueson tothenextitem. Mode Setup PressENT Then press twice,thenENT tochange toFlowand Levelmode. LevelOnly IfCu ft/secondarethedesiredFlowUnits,press tocontinuetothenextitem. FlowUnits PressENT or To change units,pressENT and toselectCu Ft/minute,Cu Ft/hour, Cubic Feet/Second Gals/minute,Gals/hour,Mil Gals/day,Liters/sec,Liters/minute,or Liters/hour. PressENT toselectdesiredVolume Units. FlowElement PressENT Press toselectthepropertypeand sizeofflowelement.Flowelementsare PalmerBowlus 4" listedon page 14.PressENT toselectdesiredflowelement. ReferenceDist The displaywillshow Manual Set which allowsyou toenterthereference(range) xx.xxunits PressENT value.RefertoFigures14and 15forflumeand weirsideviews. NOTE: Itisrecommended touse Manual Set (as opposed toAuto Set)when changing theReferenceDistance. PressENT tomanuallysetthereferencedistance.An willappear inthe Manual Set PressENT or bottom lineofthedisplay.This allowsyou tochange thereferencevalue. xxxx units Measure thedistancefrom thefaceofthetransducertothemaximum distance tobe measured.Enter valueand pressENT .IfAuto Set ispreferredpress . The liquidsurfacemust be atthepointofzeroflow.Check tosee thatthe Auto Set (Ifchosen) PressENT or distancebeingdisplayediscorrect.When you presstheENT key,thatdistance xxxx units willbe setas yourreferenceand theprogram willcontinueon tothenext selection.To continuewithoutmaking changes press . Maximum Flow The unitwillautomaticallydisplaya valueforMaximum Flowthatisbased on the xx.xxunits Press FlowElement and ReferenceDIstancethatwas entered.This can be decreased ifdesired,by enteringa new valueand pressingENT . Maximum Head The unitwillautomaticallydisplaya valueforMaximum Head thatisbased on the xx.xxunits Press FlowElement and ReferenceDIstancethatwas entered.This can be decreased ifdesired,by enteringa new valueand pressingENT . Low FlowCutoff When theflowvaluesfallbelow theLow FlowCutoff value,theflowvalueis xx.xxunits Press driventozero.The unitwillautomaticallydisplaya value0.10fortheLow Flow Cutoff.This can be changed ifdesired,by enteringa new valueand pressingENT . PreviousMenu PressENT PressingtheENT key willsetallvaluesand returntoSystem Config.PressDEL ENT toselect toreturntotherun mode.
I/OConfigurationMenu (FaultRelay#1Setting) Display Keystroke Comment and/orAdditionalKeystrokes I/OConfig PressENT Enters theRelay Settingsmenu. toselect Relay Settings PressENT AllowsentryintotheSelectRelay submenu. toselect SelectRelay PressENT Allowsconfigurationofrelay. toselect SelectRelay PressENT Enters a submenu toconfigurerelay#1. FaultRelay (#1) PressENT Moves the tothebottom lineoftheLCD. This allowsrelay#1tobe enabled Disable ifitistobe used. FaultRelay (#1) Press Pressing enablestherelay. Disable FaultRelay (#1) PressENT Moves the tothetop lineoftheLCD. Enable FaultRelay (#1) Press Moves tothenextitem. Enable Relay On Delay PressENT A one-seconddelayon therelayispresetfrom thefactorytopreventrelay 1 sec or chatteringduringturbulentprocessconditions.Press tokeep thisatone second,or pressENT tochange ittoa different(0-255seconds)value. Relay OffDelay PressENT Press tokeep thisatone second,or pressENT tochange ittoa different 1 sec or (0-255seconds)value. PreviousMenu PressENT Revertsback totheSelectRelay submenu. toselect SOFTWAR E CONFIG URATION cont. T his men u isused to configure the relaysettings,4–20m A output,and communic ation parameters of the Model 300/301.Refer to pages 13 and 14for the comp letemen u layout.Th e firstpartofthissectionshows how to configure each type of relay(fault,alarm,and lead lag).The second partshows how to configurethe 4-20mA and RS-485out - puts.The I/OConfigurationM enu can be entered from the R UN m ode by pushingENT and the pressing twice. I/OCONF IGUR ATIONM EN U T he 300/301 transm ittercan be provided with four relays, two relays,orno relays.The relayscan be configured to be fault(diagnostic)relays,alarm relays(controlledby level,vol - ume ,orflow),or lead lag(pump control)relays. RE LAY SE TTINGS Relay #1isthe onlyrelaythatcan be used as a faultrelayto indicate wh en the diagnostics of the 300/301have deter - mined thatthere isa faultcondition.T herearesixfaultcon - ditions that willchange the state of relay#1 when a fault occurs:echo loss,ringdown,transducerfail,no transducer, bad transducer, and temp erature fail. Se e the Troubleshootingsectionfordetailson each of these fault conditions. FaultR elayCon figuration
SOFTWAR E CONFIG URATION cont. Any of the relayscan be configured as alarm relays.E ach alarm relaycan be configured to be controlledby Level, V olume (wh en inVolume & Leve l mod e),or Flow(wh en in the Flow & L evel m ode). T he alarmrelayscan be configuredtohave thesam e on and offpoints,or differenton and offpoints. Alarm R elayCo nfiguration I/OConfigurationMenu (AlarmRelaySetting) Display Keystroke Comment and/orAdditionalKeystrokes I/OConfig PressENT Enters theRelay Settingsmenu. toselect Relay Settings PressENT AllowsentryintotheSelectRelay submenu. toselect SelectRelay PressENT Allowsconfigurationofrelay. toselect SelectRelay PressENT or PressENT tobeginconfiguringrelay#1(ifitwas not used as a Faultrelay)or 1 2,3,or 4 enter2,3,or 4 toconfiguretheotherrelays. FaultRelay (#1) Press FaultRelay (#1)willbe displayedonlyifyou areconfiguringrelay#1.Press Disable tokeep itdisabledas a faultrelay,and proceed toconfigureitas an alarmrelay. Enable/Disable PressENT Enables therelay.AfterenablingtherelaypressENT againtomove the back Disable and up tothetop line,and thenpress toproceed tothenextitem. ControlledBy PressENT IftheunitisintheLevel Only mode,thisscreenwillnot be shown.Iftheunitis Level or intheVolume & Level ,or Flow & Level modes,therelaycan be used to controllevel,volume or flow.Pressing willsettherelaytobe controlledby level.PressENT , ,ENT ,and ifcontrollingby volume or flowifdesired. RelayOn Point PressENT Insertsa on thebottom lineoftheLCD which allowsthevaluetobe changed. xxxx units Enter thevaluefortheon pointand thenpressENT and . RelayOffPoint PressENT Insertsa on thebottom lineoftheLCD which allowsthevaluetobe changed. xxxx units Enter thevaluefortheoffpointand thenpressENT and . Relay Action PressENT This screenwillonlyappear ifthe“RelayOn” and “RelayOff”pointsarethe DNRG < Setpoint or same.Selecteither“DNRG<Setpoint” tohave therelayde-energizeata value thatislessthanthesetpoint(low levelfail-safe),or “DNRG>Setpoint” tohave therelayde-energizeata valuethatisgreaterthanthesetpoint(highlevelfail- safe). Relay On Delay PressENT A one-seconddelayon therelayispresetfrom thefactorytopreventrelay 1 sec or chatteringduringturbulentprocessconditions.Press tokeep thisatone second,or pressENT toentera different(0-255seconds)value. Relay OffDelay PressENT Press tokeep thisatone second,or pressENT toentera different(0-255 1 sec or seconds)value. FaultMode PressENT Iftheunitdetectsone ofthesixfaultconditionsdescribedinFaultRelay OFFon FAULT or Configuration(page 22),thealarmrelayscan eitherbe configuredtoturnOFF (de-energize)or toHOLD theircurrentstate.The factorydefaultsettingisOFF . PreviousMenu PressENT Revertsback totheSelectRelay submenu. toselect As show n inthe Gen eralProgramming Menu on page 14,all fourrelays can be included ina lead-laggroup forpump con - trol.Th e factory defaultsettingisOFFforthe lead-lagmode. To set-up relaysina lead-laggroup,thelead-lagmode must be changed toone ofthefollowingfiveselections:1-2,1-2- 3,1-2-3-4,2-3,or 2-3-4.Ifrelay#1 isconfigured as a fault relay (page 22),then 2-3and 2-3-4arethe onlytwo possible relay groupings for lead-lagcontrolof pumps. Ifrelay#1is notconfigured as a faultrelay,then thelead-laggroup selec - tions are 1-2,1-2-3,or1-2-3-4. W hen configuringthelead-lagm ode you willsee thefollow - ingwarningm essage:No Alarm RelaysinLeadLag Group . This m essage m eans thatany relaysthatareincludedinthe lead-lag group m ust have different on and offpoints.The software does not allow any individualrelaysinthelead-lag group tohave thesam e on and offpoints.See Figure16on the nextpage forfurtherexplanation. Lead-L ag Relays I/OCONF IGUR ATIONM EN U cont .
SOFTWAR E CONFIG URATION cont. On point for first lead-lag relay Off point for both lead-lag relays On point for second lead-lag relay Figure 16 Lead-lagRelay Configuration Since the configuration forrelaysina lead-lag group isthe same as alarm relays,referto page 23 for configuration. Th e DNRG < Setpointscreen willnot be shown sincelead- lagrelays cannot have the same valuefor “Relay On ” and “Re layO ff.” As show n inFigure16,alltheR ELAY OFFpointsinthelead- lag group shouldbe thesam e value.This allowsthelead-lag cycletoresetw hen more thanone relaycomes on.The RELAY ON pointsforthesecond,third,and fourthrelays(ifused),are staggered above theRELAY ON pointforthefirstrelay. Lead-L ag Relays cont. I/OConfigurationMenu (4-20mA OutputSettings) Display Keystroke Comment and/orAdditionalKeystrokes I/OConfig PressENT Enters theRelay Settingsmenu. toselect Relay Settings Press Scrollstothe4-20mA Settingssubmenu. toselect 4-20mA Settings PressENT Enters the4-20mA Settingssubmenu. toselect Enable/Disable PressENT , Enables the4-20mA output.PressENT and toproceed tothenextitem. Disable Controlledby PressENT or IfunitisconfiguredintheLevel Only mode,thisscreenwillnot be displayed. Level Press tohave the4-20mA controlledby level,or ENT , ,ENT , tohave it controlledby volume or flow. 4 mA Point PressENT Insertsa on thebottom lineoftheLCD which allowsentryofthe4 mA point xxxx units value.Afterenteringthe4 mA value,pressENT and . 20mA Point PressENT Insertsa on thebottom lineoftheLCD which allowsentryofthe20mA point xxxx units value.Afterenteringthe20mA value,pressENT and . FaultMode PressENT Determinesthestatusofthe4-20mA ifa system faultisdetected.Use the Hold toselecteitherHold,22mA,or 3.5mA thenpressENT and . PreviousMenu PressENT Revertsback tothe4-20mA Settingsmenu. toselect T he 4-20 mA outputcan be controlled by either level,vol - ume ,or flowdependingon wh ich mod e was selected inthe S ystem Co nfigurationMenu. The R S -485 m enu configuresthe M odbus digitalcommuni - cationsportofthe unit. 4-20 m A OUTPUT AND RS-485 SE TTINGS I/OConfigurationMenu (RS-485Settings) Display Keystroke Comment and/orAdditionalKeystrokes I/OConfig PressENT Enters theRelay Settingsmenu. toselect Relay Settings Press twice ScrollstotheCommunication PortSetup submenu. toselect Comm PortSetup PressENT Enters theCommunication PortSetup submenu. toselect Address (0-247) Press or ENT This screenisused tosettheaddress forthisparticularunitduringpolling.Enter 1 theaddressviathekeypad.Make surethatno otherunituses thissame address. Baud Rate Press or ENT Set thebaud rate(communication speed)fortheunit.Baud ratesof9600,4800, 9600 2400,or 1200areavailable.Enter thebaud rateviathekeypad.This valuemust match theModbus settingsofyoursystem. Parity Press or ENT Set theparitybitatEven,Odd,or None viathekeypad.This valuemust match Even theModbus settingsofyoursystem. PreviousMenu PressENT Revertsback totheCommunication PortSetup. toselect I/OCONF IGUR ATIONM EN U cont .
SOFTWARE CONFIG URATION cont. The Advanced C onfiguration m enu setsmany parametersthat are not normallyused in the operationof the unit.Th e Advanced C onfiguration menu can be accessed from therun m ode by pressing E NT and or untilthedisplayshows: The entire Advanced Co nfigurationmen u isshown below, followedby theconfigurationinstructionsforeach item. Adv Config toselect Advanced ConfigurationMenu Menu Display Menu Item Explanation Adv Config Enters theAdvanced Configurationmenu. PressENT . toselect Calibrate Used toadjustforthespeed ofsound iftheultrasonicsignalisgoingthroughmedia otherthanair. xxxx units NOTE: Itisstronglyrecommended toconsultthefactorypriortousingthisfeature! Gain Limit Used tolimitthegaintoa valuebetween 0and 32.Since theunitadapts itsgaintosuittheapplication,itisnot 32 recommended touse thisfeatureunlessinstructedtoby thefactory. StartingGain Used toadjustthestartinggaintoa valuebetween 0and 32.Since theunitadaptsitsgaintosuittheapplica tion, 0 itisnot recommended touse thisfeatureunlessinstructedtoby thefactory. Damping (1-60) Used tosetthedamping (1-60seconds)fortheunit.This valuecan be changed depending on how turbulentthe 6 processis,or iftherateoffillisveryfastor slow. Echo Loss Delay Used toseta delay(1-150seconds)oftheFaultAlarm (relay#1)when an echo lossoccurs. 1 sec DefaultDisplay Allowsthedefaultdisplaytobe changed from Level toLoop (4-20mA),or Volume or Flow ifintheVolume or Level Flow mode. Change Password The factorypresetpassword is300.This screenisused tochange thepassword forsecuritypurposes. toselect AdjustLoop Pts OffsetstothemA currentloopcan be made. toselect Enter Tag Line Used toreplacethe“MagnetrolInt’l”tagwitha user-definedtagsuch as vesselnumber or location.Any toselect alphanumericcharacterscan be enteredas a tag. PreviousMenu Revertsback tothebeginningofAdvanced Configuration. toselect Calibrate NOTE: Itisnotrecomm ended to use the calibrate feature unless specificallydirected todo so from thefactory. T he Mo del 300/301performs levelme asureme nt by timing how long ittakes for a round tripultrasonicpulse to travel from the face of the transducer to the liquid surfaceand back.T he mea suremen tassum es thatthis round tripisinair w herethespeed ofsound is1128feet/second.This speed of sound is altered whe n going through gases otherthan air. T he C alibrate mo de can be used to adjustfor the speed of sound w hen going through hom ogenous (not stratifiedlay - ers)gases otherthan air.However,since m ostgases existas stratified layers of vapors above the liquid surface,the C alibratemod e israrely used. Wh en enteringthe Ca libratem ode,the display w illindicate the distance thatthe 300/301has me asuredfrom thefaceof the transducerto the liquidsurface.Ifthis distance isinerror, m easurethe actualdistanceand enterthisvalue. NOTE: Usin g the Calibratemo de may cause false levelread - ings.C onsultfactoryforresetprocedures. Gain Lim it This displays thevalueofmaximum gainthattheunitwilluse. This valueis from 0-32 and the unit steps up insingle-gain incrementsuntila suitable signalis received.Limitingthegain toa lowervalue may help withsecondaryecho problems. En tera valuebetween 0and 32.Ente rPassw ord willbe dis - played and your chosen passwo rd must be entered at this time.Press ENT to acknowledge thepassword. Gain L imitcont. The M odel300/301adapts itsgainto suitthe conditionsof the application.T hereare32 gainsteps.The higherthenum - ber,the highergain/driverequiredto detectan acceptable signal. StartingGain The gainstartsout ata valueofzeroand adjustsitselfto a value(between 0 and 32)such thatitcan reliablymeasure the liquidsurface.Approximatelyonce a minute itwillreini - tialize thegainstarting from zerotomake surethattheunitis measu ringtheproper distance.T hisisparticularlyhelpfulin tallvesselsor those applicationswith turbulentsurfaces.A higherS tartingGain valuewilldecreasethe timefortheunit to achievethe properGain value.Adjustingthe startinggain shouldnotbe done withoutconsultingthe factory. Da mping The factorydefaultvalue is 6seconds fordamping. This valuecan be changed (from 1-60)depending on the rateof fill(or em pty)of the vessel.Largerdamping valuescan be beneficialifthe liquidsurfaceisturbulentdue to the vessel fill,or agitationfrom a mixer. E cho Loss Delay Used toseta delay(1-150seconds)oftheFaultAlarm (relay #1)when an echo lossoccurs.This helps to avoid a fault alarm ifthe 300/301m om entarilylosesthe ultrasonicsignal due to excessive turbulence,foam or other application param eters. ADV ANCE D CONFIG URATION M ENU
SOFTWAR E CONFIG URATION cont. DefaultDisplay T he factorydefaultisfortheunittodisplayMagnetr olInt’lon the top line of the LCD whileinthe run mod e,and a level readingon the bottom line.The bottom line can be changed to display the m A currentloop output value instead of the levelreading.W hen using the Volume & Le vel mode, the default displaycan be changed to be volum e.When using the Flow & L evel m ode the defaultdisplaycan be changed to be flow . Chang e Passwo rd Allows forthe factory presetpassword of300tobe changed to anothervalueforsecuritypurposes.The password can be any numb erbetween 1 and 32767.The format istoenterthe oldpasswo rd,enter the new password,and then enterthe new password again. AdjustLo op Points Offsets to the mA current loop can be made ifnecessary. T his is done by reading the m A current output with a DV M ,and adjustingthe 3.5m A and 22 mA endpointswith AdjustLo op Pointscont. the or keys.These valuesare set at the factoryand shouldnot need tobe adjusted.Contact thefactorypriorto m akingany adjustmentstothe loopoutput. E nterTag Line The upper line oftheLCD displaywhileintherun mode isa programm able labelreferredto as thetag.Itispresetatthe factoryas “M agnetrolInt’l.”Ifdesired,thistag can be changed to be any alphanumericstringof 16characters. PressE NT and thenuse or toscan through thecharac - ters.Pressing E NT willentera characterand move thecursor to the next position on the LCD line.Upper and lowercase lettersareprovided as wellas num bersand many ASCII char - acters.Pressing DE L m oves the cursorback one position. Pressing the once willstarta scrollingof the characters, and pressing ittwicewillstarta fastscrolling.When closeto thedesiredcharacter,pressE NT and use or toreachthe desiredcharacter.A blankspace m ay alsobe used.The blank space is found in between the !and the whilescrolling throughthecharacters. T he D iagnostics Menu provides a method of testingthe instrumen t’sfunctionality.Italsohas usefulinformationfor troubleshooting.Access to DiagnosticsMenu is obtained from the run mod e by pushingeitherthe or arrows until the display show s: Diagnostics toselect DiagnosticsMenu Display Option ActionifENT ispressed Comments Test Relays PressENT tochange Selectrelaytotest,pressENT, then Allowusertoenergizeany relay toselect or or tocontinue. use or toenergizerelay. individually.PressENT when complete. Test 4-20mA Loop PressENT tochange Enter desiredcurrentoutputand Allowsusertooutputdesired4-20mA toselect or or tocontinue. pressENT . toan externaldevice.PressENT when complete. Gain/% Signal Press or tocontinue. This isa read-onlyscreenthatcannot The gainwillincrease(from 0to32)to xx xxx be changed. keep the% signalstrengthata desired levelforpeak performance. View Version# Press or tocontinue. Displaysoftwareversionnumber. xxxxxxxxxx PreviousMenu PressENT toreturnto toselect previousmenu or or toreviewselection. ADV ANCE D CONFIG URATION M EN U cont . DIAGNOS TICS ME NU
T his protocol guide explainsthe operationof the Modb us protocolper Mo dicon docum entPI-MBU S-300Rev J. T he Ma gnetrolimplementationof the Mo dbus protocolpro - vides a standard form of digitalcommu nications.An effort has been mad e to parallelcurrent implementationsto the greatest extent possible,so that Magnetr ol products com - mu nicate with existingM odbus m asters. Ch eck com patibilitycarefullyto ensure that the Mode l 300/301is configured forthe data formatexpected by the host compu ter.Excep tionsm ade because of the unique requirements of the M agnetrolinstallationhave been noted. Th isisno guarantee,however,thatthe interpretation made here w illbe thesame as thatfollowedby theMod bus master. Th e Magnet rolimplemen tationofthe Modbus protocolpro - videsforthe passingof measured and calculatedvariables, configuration information,and diagnosticsindata registers. Data is sentin theseregistersas floatingpointvalues,integer values,numeric codes relatedto configurationlists,status summary w ords (packed bits),orindividualflags(singlebits). On e master and up to 31 unitsm ay be multi-dropped on a singleRS-485commu nicationbus. T he M odbus functions implemented in Mod el300/301are listedin Tab le3. CONFIGURATION The M odbus porton theM odel300/301must be configured to establishcom mun ications.The keypad allowstheuserto setthe M agnetrolM odbus portto match the Modbus mas - ter.S ee page 24forconfigurationinstructions. M agnetroladdresses provideunique identificationforthe host.T hisaddress m ay range from 1 to 247and must be unique.Each M odel 300/301only responds when a query has been senttoitsuniqueaddress by the host. M agnetrolunitssupport the Remot e Terminal Unit (RTU) m ode of transmission.RTU provides improved errordetec - tioncapabilitiesand higherthroughputthantheASCII mode. The R S -485 port m ust be configured for a transmission speed (baud rate).Allowablevaluesare1200,2400,4800,or 9600bitsper second. Function Function InformationType M ODBUS Co de No me nclature
01 Read 1-bitcoils Read coilstatus
02 Read 1-bitcoils Read inputstatus
03 Read 16-bitregister/integer Read holdingregisters
04 Read 16-bitregister/integer Read inputregisters
05 Write 16-bitregister/coils Forcesinglecoil
06 Write 16-bitregister Presetsingleregister
15 Write 16-bitregister/coils Forcemultiplecoils
16 Write 16-bitregister Presetmultipleregisters
Exception: Because theModel 300/301does not distinguishbetween inputsand outputs,functioncodes 01and 02(as theyapplytobits)and functioncodes 03and 04(as theyapplytonumeric values)refertothesame data registers. Table3 M odbus Functions MODBUS PROTOCOL
T he serialcomm unication fortheMod el300/301isdesigned to comm unicate witha host comp uterover two wires ina mu ltidrop system. E ach transmitterinthesystem isassigned a uniqueaddress thatthe com puteruses tocomm unicatewiththattransmitter. COMM AND/RE SPONSE SEQ UENCE T he system uses halfduplex com m unicationwiththe host com puteractingas the m asterand the300/301transmitters acting as the slaves.Th e 300/301transmitterisdesignedfor 1 m aster comp uter and up to 32*slaves.Each slavehas a unique address between 1 and 247 associatedwithit.Th e addressisused towa ke up thetransmitterand interrogate it fordata. T he host willsend down a com m and to the unitusing the addressto wake itup.T he unitwillthen analyzethe com - ma nd and retrievethe appropriatedata.Aftersending back a response,theunitwillreturntothe sleepmod e. On lythe hostcomput er can issuea comman d.Each com - ma nd containsthe unitaddress,thefunctioncode,thedata, and the error checking valve.Mag netrol products support the C RC errorcheckingvalve. *See cablerequirementsforthe maximum number of unitsallowed forintrinsicallysafeoperation. T he M odbus datainthe Mo del300/301isarranged ininte - ger register,floatingpointregisters,and status bits.Th e assignmen ts for these registers are found in the tableson pages 30and 31.Functioncodes 03,04,06,and 16areused w ith integerregisters. Function codes 01,02,05,and 15areused withstatusbits. Bo th integer and floating-point registers have space reserved to reorder the registersform aximum communica - tion throughput. A comp lete descriptionof allthe preceding commands, except floating point,can be found in Modicon Mod bus ProtocolRe ference Guide,docum entnumber PI-MBUS-300 R ev J. INTE GER REGIS TE RS Integer registers are the m ost commonly used type of M odb us dataand are supported by most Modb us hosts.In the M agnetrol implementation,the Mod bus registers are arranged inone ofthe followingfourformats: 1. IntegerD ata:A scalednumb erfrom 0to the maximum M odbus integer. 2. Character D ata:Two ASCII charactersper 16-bitregis - ter(i.e.,date,password). 3. Coded D ata:Mu ltiplechoiceconfigurationdata chosen from a coded list. 4. Packed B its:Registerform of16packed singlebits The integer,character,and coded dataregisterscontainallof the informationneeded to configureand read process data. Any integerregisterm ay be read withfunction code 03 or function code 04.These sam e registersmay be writtenone ata time withfunctioncode 06or mu ltipleregisterscan be writtenwithfunctioncode 16. FUN CTIONS AND DATA FORM AT PROG RAMMING RXD/TXD + RXD/TXD –□ Figure17 Command from Host Response from Transmitter
- Transmitter Address□
- Function Code□
- Data Bytes□
- Error Check
- Transmitter Address□
- Function Code□
- Data Bytes□
- Error Check Response to Host Command to Transmitter Figure 18
M odb us sets up the data in a m emory map. The memory m ap issetup inregistersthatare2 bytesinlength.The read only registers are num bered form 30001to 39999. The read/writeregistersare num bered from 40001to 49999.In orderto access theseregisters;an offsetissent.Forexam - ple,ifthe data inregister30001isto be read,an offsetof 0000issent. Individualbitsinthe bitregistersare addressed by a sepa - ratedm ap.The read onlybitsare numbered from 10000to 19999 and theread/writebits arenumbered from 0to9999. Inthe XXXX unit,both addresses willaccess the same bit. T he offsetfor these bitsisthe sam e as the registers.For exam ple,if10003istobe read,and offsetof0002issent. M ODE L 300/301MODB US M APPING A m aximum and m inimum valueof0indicatesthatthevalue isR ead Only.Care m ustbe takenwhen disablingrelays.The relaywillhold the laststatewhen itisdisabled.RS-485is used forexternalcom m unications usingModbu s . The M odel 300/301Transm itteruses the Modbus RTU pro - tocol.The usermu stentertheBAUD rateand theparitythat the master willbe using.See page 24 for configuration instructions.Each of these param etersmust be set at the unitbeforecom m unicationcan occur. 1. B AUD rate:1200,2400,4800,9600. 2. Parity:Odd (8,O,1),Even (8,E,1),or None (8,N,2). PROGRAM MING cont. CHAR ACT ER FRA M ING T he Mo del 300/301is factoryconfiguredfor 9600baud, even parity,and 1 stop bit.Inserialcommunication,thebits are sentoutone ata time,leastsignificantbitfirst.These are surrounded by a startbit(always low)and a parity bitor a stop bit (ifa parity bit,itwillbe followed by a stop bit) (alw ays high). Figure19 M E SSA GE FR AM ING Allm essages startand end withan idletimeof3.5character times.For the 300/301thisvalueisapproximately4 ms at 9600baud.This willletallthe unitsknow thatthe nextbyte to follow isthe address field. Figure20 Be cause of thismethod fordetermining the address byte, the entireme ssage m ustbe sentina continuous stream.If an idletime ofmore than 1.5charactertimesoccursbefore the completionof the messa ge,the next byte receivedw ill be assumed an address byte and the previouslyreceived bytes w illbe ignored. Start 012 3456 7 Stop Address Function Data CRC Check
3.5 Character
3.5 Character□
Less than 1.5 Character Times Stop Parity
PROGRAM MING cont. Command Register# Comments ForcesLoop toLoop ForceValue 00001 Forceslooptoloopforcevalue On/Off Enables Loop Control 00002 Enables loopcontrol On = Enable; Off=Disable Relay #1toForceOn Value 00003 Relay #1diagnostictest On = Enable; Off= Disable(normal operation) ForceOn Value (Relay #1) 00004 Off= De-Energized;On= Energized Relay #2toForceOn Value 00005 Relay #2diagnostictest On = Enable; Off= Disable(normal operation) ForceOn Value (Relay #2) 00006 Off= De-Energized;On= Energized Relay #3 toForceOn Value 00007 Relay #3 diagnostictest On = Enable; Off= Disable(normal operation) ForceOn Value (Relay #3) 00008 Off= De-Energized;On= Energized Relay #4toForceOn Value 00009 Relay #4diagnostictest On = Enable; Off= Disable(normal operation) ForceOn Value (Relay #4) 00010 Off= De-Energized;On= Energized Enable Relay #1 00011 Off= Disable;On = Enable Relay ActionforRelay #1 00012 Off= DNRG <Set point;On = DNRG > Set point Relay #1as FaultRelay Setting 00013 Off= Normal;On = Fault(Read Only —Functions1 or 2) Enable Relay #2 00014 Off= Disable;On = Enable Relay ActionforRelay #2 00015 Off= DNRG < Set point;On = DNRG > Set point Enable Relay #3 00016 Off= Disable;On = Enable Relay ActionforRelay #3 00017 Off= DNRG < Set point;On = DNRG > Set point Enable Relay #4 00018 Off= Disable;On = Enable Relay ActionforRelay #4 00019 Off= DNRG < Set point;On = DNRG > Set point M ODE L 300/301MO DBUS M APPING cont. 1-BITCOIL VAL UES Minimum Maximum Maximum Command Register# Comments Decimal Decimal Hex Value Value Value Damping 40001 Output damping valuesinseconds 1 60 0x 3C Units 40002 1 = inches;2 = feet;3 = centimeters;4 = meters 14 0x 04 Lead–Lag Relay Select 30003 RefertoLead–Lag group sizetable* 3 15 0x 0F (read only—functions3 or 4) Lead–Lag Relay Quantity 30004 RefertoLead–Lag group sizetable* 24 0x 04 (read only—functions3 or 4) On Time Delay — Relay #1 40005 Time delaybeforerelayenergize(seconds) 0 255 0x FF OffTime Delay — Relay #1 40006 Time delaybeforerelayde-energize(seconds) 0 255 0x FF On Time Delay — Relay #2 40007 Time delaybeforerelayenergize(seconds) 0 255 0x FF OffTime Delay — Relay #2 40008 Time delaybeforerelayde-energize(seconds) 0 255 0x FF On Time Delay — Relay #3 40009 Time delaybeforerelayenergize(seconds) 0 255 0x FF OffTime Delay — Relay #3 40010 Time delaybeforerelayde-energize(seconds) 0 255 0x FF On Time Delay — Relay #4 40011 Time delaybeforerelayenergize(seconds) 0 255 0x FF OffTime Delay — Relay #4 40012 Time delaybeforerelayde-energize(seconds) 0 255 0x FF Current Relay Status 30013 Data containedinlowerbyte 0 15 0x 0F All“Off”= 0000;All“On” = 000F Loop Control Bits 40014 Bit 0: Set to0 0 26 0x 1A Bit 1: 1 = enable;0= disable Bit 2: Set to0 Bit 4–3: Faultmode: 01= 22mA 10= 3.5mA 11= Hold Bits 5–7:Set to0 Bits 8–15:Set to0 16-BITRE GISTER VALUE S
Command Register# Comments Decimal Decimal Hex Value Value Value Relay #1Control Bits 40015 Bit 0: 1 = enable;0= disable 0 27 0x 1B Bit 1: Relay action Relay #2Control Bits 40016 0= DNRG < setpoint 1 = DNRG > setpoint Relay #3 Control Bits 40017 Bit 2: Set to0 Relay #4Control Bits 40018 Bit 4–3: FaultMode: 00= De-energize 01= Hold Bits 5–15:Set to0 DiagnosticBits 30019 Bit 0–7:Set to0 Bit 8: 1 = No returnsignal;0= No error Bit 9: 1 = Ringdown error;0= No error Bit 10:1 = Transducerfault;0= No error Bit 11: 1 = No transducer;0= No error Bit 12: 1 = Bad transducer;0= No error Bit 13:1 = Temperature fault;0= No error Bit 14–15:Set to0 (read only— functions3 or 4) Relay #1ForceControl Bits 40020 Bit 0: Forcerelaytoforcedstate 03 3 1 = enable;0=disable(normal operation) Relay #2ForceControl Bits 40021 Bit 1: Forcedrelaystate 1 = Energize;0= De-energize Relay #3 ForceControl Bits 40022 Bits 2–15:Set to0 Relay #4ForceControl Bits 40023 LevelReading 30024 Levelreading(levelininchesx 10) Flow/VolumeReading 30025 Flow/volumereading(x 10) 4–20mA Reading 30026 4–20mA reading(x 10) Range 40027 Range value(x 10) Span 40028 Span value(x 10) 4–20mA Force 40029 Loop valueforloopdiagnostics(x 10) 35 220 0x DC 4 mA Point 40030 4 mA Point(levelininchesx 10) 0 4800 0x 12C0 20mA Point 40031 20mA point(levelininchesx 10) 0 4800 0x 12C0 Relay #1OffPoint 40032 Pointininches(x 10) 0 4800 0x 12C0 Relay #1On Point 40033 Pointininches(x 10) 0 4800 0x 12C0 Relay #2OffPoint 40034 Pointininches(x 10) 0 4800 0x 12C0 Relay #2On Point 40035 Pointininches(x 10) 0 4800 0x 12C0 Relay #3 OffPoint 40036 Pointininches(x 10) 0 4800 0x 12C0 Relay #3 On Point 40037 Pointininches(x 10) 0 4800 0x 12C0 Relay #4OffPoint 40038 Pointininches(x 10) 0 4800 0x 12C0 Relay #4On Point 40039 Pointininches(x 10) 0 4800 0x 12C0 16-BITRE GISTER VALUE S cont. PROGRAM MING cont. L ead-La g Re laySelect Lead -Lag RelayQuantity Description 0x 03 2 Relays1 & 2 0x 07 3 Relays1,2,& 3 0x 0F 4 Relays1,2,3,& 4 W ithRelay 1 setas a FaultRelay 0x 06 2 Relay 2 & 3 0x 0E 3 Relay 2,3,& 4 *LE AD-L AG GROUP SIZE (REGISTER 30003,30004)
Ch eck forthe followingsensitivitiesbeforeproceeding tothe nextsection: Ifany ofthe above sensitivitiesarepresent,consultthe fac - toryforrecomme ndations. INSTAL LA TION CHECKLIST Cable 1. _____ Wa s B elden 8102used? Ifothercablewas used, permanent dam age m ay have been done to the transm itter. 2. _____ Istransducerwiringrun ina dedicated conduit? 3. _____ Istransducershieldconnected atbothends? Transducer 1. _____ C heck transducer alignmen t.Isitvertical? 2. _____ Istransducerm ounted hand tight? Overtighteningma y cause ringing,some installa - tions ma y requireusinga shock absorber. 3. _____ Ism inimum nozzlediameter8 inches? 4. _____ Ism aximum nozzleheight11 inches? 5. _____ C heck beam pathforobstructions,including tank w all.R efertopage 6forUltrasonic Beam Sp read. 6. _____ C heck transducerhousing formoisture. TROUBLES HOOTING Process 2. _____ Arevaporspresent?Visiblevaporsmay cause falselevelreflections,invisiblevapors may alter speed ofsound. 3. _____ Isliquidsurfaceturbulent? 4. _____ D oes thetank have a m ixingblade? Could itbe providingfalselevelreadingsor creatinga vor - tex resultinginecho loss? Transmitter Enter the specifiedm enu,and obtainthe followinginforma - tionbeforeconsulting thefactory. M easured ValuesMenu System Con figuration Diagnostics M enu OTHER INFORM ATION 2. W hatisthedistancefrom the 3. W hatisthetransmitter’s 4. W hatisthetemperature? 5. W hatisthem edia RS -485WIR ING S tandard Be ldon 8451 shielded,twisted pair,22-gauge stranded conductors m ay be used for interconnectionof units.Order cable through Ma gnetrol (part number,009- 7146-001),specifylength atthe time oforder;10feet(3 m) m inimum,5000feet(1524 m )m aximum. T he preferred method of wiring isthat allunitsbe wired in parallel.Itispermissibleto have branches,not exceeding five feet,from the ma in wiringtrunk.One master witha max - im um of31 slavedevices isallowable. 1. C onnect terminalA from the m asterdeviceto terminal A on allslavedevices. 2. C onnect terminalB from the m asterdeviceto terminal B on allslavedevices. 3. Connect shieldingfrom ground ofm asterto ground on allslavedevices. NOTE : Polarityam ong unitsinloop must be observed. T he masterdeviceand last(farthest)slavedeviceintheloop m usthave a terminationresistor.This resistor isprovidedin the M odel300/301by jumper placement of JP1.The termi - nationjumperJP1 islocatedunder theshield,below theRS- 485terminalblock.The jumper JP1shouldbe inpositions2 and 3 (factoryposition)forallslavedevicesexcept the last (farthest)deviceintheloop,which shouldhave thejumper in positions1 and 2.
TROUBLES HOOTING cont. Follow ing are troubleshootingdisplays which couldappearon theModel 300/301. Display Cause Solution FACT PARAM FAIL The factoryparametersdealing PressENT tocontinue.This loadsthedefaultvaluesforthe withlevelmeasurement arecorrupt. factoryparameters. TAG LINE LOSS The taglinecharactersarecorrupt. PressENT tocontinue.This loadsthedefaulttaglineintolong-term memory. Ifyou areusinga custom tagline,thetaglinemust be re-entered. SYS PARAM FAIL The main parameters,which store PressENT tocontinue.This loadsdefaultvaluesforthemain range,span,and communications, parameters.VerifyalloftheitemsintheSystem Config menu. etc.arecorrupt. STRAP TABLE FAIL There isan errorinthecustom PressENT tocontinue;thetableiscleared.Ifa custom tableisnot table(linearor spline)entry. beingused,thenthiserrorcan be ignored.Ifyou areusinga custom table,thetablehas tobe re-entered. FV PARAM FAIL The flowor volume parameters Reconfigureflowand volume settings. arecorrupt. LOOP PRESET FAIL The looppresetsarecorrupt. The loopwillhave tobe recalibratedintheAdvance Config menu under AdjustLoop Points. RELAY PARAM FAIL The parametersforRelays PressENT tocontinue.The relaysaredisabled,and thesettingsare arecorrupt. settodefaultvalues.Reconfiguretherelaysfrom theI/OConfig menu. LOOP PARAM FAIL The 4–20mA loopparameters PressENT tocontinue.The loopisdisabledand thesettingsareset arecorrupt. todefaultvalues.Reconfigurethe4-20mA from theI/OConfig menu. TRANSDUCER FAIL The unitwas not abletodetecta Ensure thatthetransducerisconnected properlytotheunit.Try NO TRANSDUCER transducerconnected or was not replacingthetransducer.Returntheunitforrepair. OR abletodeterminethetransducer’s BAD TRANSDUCER frequency. ECHO LOSS The unitisnot abletodetecta Ensure thattheleveltobe detectediswithintherange and span of returnsignalfrom thetransducer. theunit.Check theapplicationforfoam,obstructions,or heavy vapors. RINGDOWN The transducerisringinglong Try decreasingthespan toincreasethedead band (rangeminus span) enough toringintothelevelspan of oftheunit.Try replacingthetransducerbecause thecurrenttrans- theunit. ducer may have a problem thatcauses ittoringan extralongtime. TEMPERATURE FAIL The signalfrom thetemperature Check tosee thatthetransducerwiresareconnected properly.Ensure transducerinthetransducerisout thatthetransducerwiresarenot shortedor open. ofrange.Eithera shortor open lead detected. INVALID PASSWORD The password enteredisnot valid. Retrythepreviousoperationand entertheproperpassword. LOOP OUT RANGE The calculatedvaluefortheloop Iftheleveliswithina normal operatingrange,adjusttheloop outputisgreaterthan20mA or parameterstoallowpropertrackingofthelevel. lessthan4 mA. The loopoutputwill be initsfail-safemode.
TR ANSM ITTER SPE C IFICATIONS Description Specification Su pplyVoltage 240Va c +10% /-15% ,50-60Hz 24Vd c +/-20% Power Consumption 12wattsmaximum Analog outputsignal 4–20mA (isolated) Activemode maximum 1,000Ω loopresistance 4–20mA (isolated) Analog outputsignal loopresistancedependent on Passivemode power supply Digitaloutput RS–485 withModbus Relays 10amp SPDT resistive(none,2,or 4) Fail-safe User selectableforanalog and relayoutputs Ambient Temperature (Electronics) -40°Fto+160°F(-40°C to+71°C) Display Two-linealphanumericLCD (16charactersper line) Keypad 16-button Humidity(Electronics) 99% non-condensing Fuse(Non-replaceable) 3⁄8 amp,250Vac Slo-Blo ® forAC units 11⁄2 amp,250Vdc Slo-Blo ® forDC units TRA NS DUCE R SPECIFICATIONS PERF ORMA NCE SPECIFICA TIONS Description Specification Response time 2 seconds typical Accuracy ± 0.25%ofcalibratedspan Description Specification TransducerFrequency 38 kHz Maximum Range 30feet(9.1m) Maximum Span 28.5feet(8.7m) Dead Band 18inches(460mm) minimum Ambient Temperature -40°Fto+163°F(-40°C to+73° C) (Transducer) non-operationalto+250°F(121°C) Temperature Automaticoverrange oftransducer Compensation operatingtemperature OperatingPressure –10to+50psig(–0.689to+3.45Bar) Beam Angle Conical 12° Cable length 500feetmaximum (between transducer and electronics) FM AGE NCY APPROVALS CS A AGE NCY APPROVALS Model Approval Non-hazardousenvironment 300-RXXX-45X, Type 4X enclosure 301-RXXX-400 Hazardous environments and Class I,Division1,Groups B, C, & D 384-XK0X-0XX Class II ,Division1,Groups E,F ,& G Class III 384-XK1X-0XX Hazardous environments and Class I,Division1,Groups C & D 384-XKYX-0XX Class II ,Division1,Groups E,F ,& G Class III These unitshave been testedto EN 50081-2and EN 50082-2and areincompliancewiththeEMC Directive89/336/EEC. Model Approval Indoorsand outdoors 300-RXXX-45X, NEMA Type 4X and IP65 301-RXXX-400 Hazardous locations and Class I,Division1,Groups B, C, & D 384-XKXX-0XX Class II ,Division1,Groups E,F ,& G Class III 3.87 (98) Rotation clearance 2" NPT Process Connection 3.00 (76) or 10.00 (254) Insertion Length 5.93 (151) 1" NPT (plugged) 12.25 (311)1" NPT 8.46 (215) 2.12 (54) Insertion Diameter
2 Holes
.38 (10) Dia. 3.00□ (76)2.00 (51) 2.37□ (60) 3.50 (89) 3.87 (98)□ Rotation□ clearance 3.75□ (95) 5.93□ (151) 10.68□ (271) 1" NPT 1" NPT 8.46□ (215) 3/4" NPT Plug M odel301 Remote Mount withBracket Mo del300IntegralMo unt DIMENS IONAL SPECIF ICAT IONS Inches (mm) Figure 21 Transmitters
SPECIFICA TIONS cont. 2" NPT□ Process□ Connection 3/4" NPT Insertion Length□ 10.00 (254) 2" NPT□ Process□ Connection Insertion Length 3/4" NPT
384 Transducer with
1"NPT withoutHousing
384 Transducer w ith
2"NPT withoutHousing
384 Transducer with2"NPT withHousing
Thisdimensioniscommon to all transducers on page. DIM E NSIONA L SPECIFICA TIONS Inches (mm ) Item Description PartNumber
1 Cover 004-9174-007
2 Base 004-9188-004
3 O-Ring 012-2201-253
4 Daughter board 030-3559-001
4–20 030-2225-001
5 Logicboard RS-485 030-2225-002
4–20/RS-485 030-2225-003 0relays 030-2212-003 120VAC 2 relays 030-2212-002 4 relays 030-2212-001
6 Power supply 0relays 030-2212-006
board 240VAC 2 relays 030-2212-005 4 relays 030-2212-004 0relays 030-2212-009 24VDC 2 relays 030-2212-008 4 relays 030-2212-007
7 Terminationboard 030-3515-001
Transducer Aluminum 004-9104-001 housingbase 316SS 004-9140-001 Transducer Aluminum 004-9105-001 housingcover 316SS 004-9142-001
10 TransducerhousingO-ring 012-2101-345
11 Transducer(RefertoModel Identificationon page 2. Figure23 Replacement Parts
BU LLE TIN:51-624.1 EF FEC TIVE :M arch 2011 SU PE R SEDES :June 1999 PR ODUCT WA R RANTY AllM agnetrol electronicand ultrasonicleveland flowcon - trols arew arranted freeofdefectsinma terialsor workma n - shipfor one fullyearfrom the date of originalfactoryship - m ent. Ifreturned w ithin the wa rranty period; and,upon factory insp ec tion of the con trol,the ca use of the claim is de termined to be covered und er the warr an ty;then, M agnetrolwillrepairorreplace the controlatno costto the purchaser(orow ner)otherthantransportation. Mag ne trolsha llnot be liable formisapplication,labor claim s,director consequentialdam age or expense arising from the installationoruse ofequipm ent.T hereareno other w arranties exp ressed or implied,except specialwritten w arranties coveringsom e M agnetrolproducts. Q UA LITY ASSURANCE T he quality assurance system inplace at Ma gnetrolguarantees the highest levelof quality throughout the company .Mag netrol is com mitted to providing fullcus tom er satisfaction bo th in quality produ cts and qualityservice. The Magnetrol qu al ity assurance system isregisteredto ISO 9001 affirm ing its com m itm entto know n international qu ality stand ards providing the stron gest assurance of product/servicequalityavailable. IMPORTAN T SE R VICE POLICY Ow nersof Ma gnetrolmay requestthe returnofa controlor any partofa controlforcom pleterebuilding orreplacement. T hey w illbe rebuiltor replaced promptly.Con trolsreturned under ourservicepolicym ustbe returned by Prepaidtrans - portation.Ma gnetrolwillrepairor replace the controlat no costtothe purchaser(orown er)otherthan transportationif: 1.Re turned withinthewarrantyperiod;and 2.T he factory inspection findsthe cause of the claimto be covered underthe warranty. Ifthe troubleisthe resultof conditionsbeyond our control; or,is N OT covered by the warranty,there willbe chargesfor laborand the partsrequiredtorebuildor replacethe equip - m ent. In some cases itm ay be expedientto ship replacement parts;or,in extreme cases a complete new control,to replace the originalequipm entbeforeitisreturned.Ifthisis desired,notify thefactoryofboththe mo deland serialnum - bersof the controlto be replaced.Insuch cases,creditfor the m aterialsreturned willbe determinedon thebasisofthe applicabilityofourwarranty. N o claims for m isapplication,labor,director consequential dam age willbe allowed. RE TURN M ATE RIAL PROCEDURE S o thatwe m ay efficientlyprocess any materialsthatare returned,itisessentialthata “ReturnMaterialAuthorization” (R M A) num ber be obtained from the factory,priorto the m aterial’s return.This isavailablethrough a Magnetrol local representativeor by contactingthe factory.Pleasesupply the following information: 1.Com pany Name 2.D escription ofM aterial 3.S erialNu mber 4.R eason forR eturn 5.Application Any unitthat was used in a process m ust be properly cleaned in accordance with OSHA standards,beforeitis returnedtothefactory. A M aterialS afetyData Sheet (M SDS) m ust accompany m aterialthatwas used inany m edia. Allshipm ents returned to the factorymust be by prepaid transportation. Allreplacementswillbe shipped F .O.B.factory. NOTE : S ee ElectrostaticDischargeHandlingProcedure on page 6. ASS UR ED Q U AL ITY & SER VICE COST LESS 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-400 0 • Fax 630-969-9489 • www.magnetrol.com