3320 BURKERT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 22
Technical content
Visit product website DATA SHEET Type 3360 Electromotive 2-way angle seat control valve Type 3361 Electromotive 2-way globe control valve Type 3321 Electromotive 2/2-way globe valve (ON/OFF) Standard | EU | en | 2023 - 09 - 05 | 18 Electromotive 2/2-way angle seat valve (ON/OFF)
- Safety position via energy storage Rapid flow shut off Weather and impact resistant design Hygienically designed surface Versatile diagnostic options The innovative Bürkert on/off valve Type 3320 is the solution when it comes to shut-off tasks under demanding operating conditions. The electromotive ac- tuator of the angle seat valve with ball screw moves the swivel plate at a par- ticularly high rate up to 6 mm/s to the desired end position. Thereby it reacts almost instantaneously to process signals. If necessary, the safety position can be approached by an optional energy storage in case of power failure. The electromotive actuator and shut-off valve are adapted perfectly to each other with closed design and robust surface. This ensures the hygienic re- quirements of fast and residue-free cleaning. Harsh ambient conditions are no problem for the electromotive angle seat valve Type 3320 due to the protection class IP65/IP67 and the high impact and vibration insensitivity. Thanks to the tried-and-tested, self-adjusting pack- ing gland with exchangeable V-seals, the angle seat valve achieves maximum service life and tightness. The fieldbus-suitable Type 3320 shut-off valve offers the operator many help- ful functions for process monitoring, valve diagnostics and preventive mainte- nance and therefore the decisive advantage of modern process automation. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 3320 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 22Visit product website Table of contents 1. General technical data 3 Approvals Materials 3.2. Material specifications 4. Dimensions 6 4.2. Body with threaded connection .... 4.3. Body with welded connection.... 4.4. Body with clamp connection ... 5. Performance specifications 13 Overview of flow characteristics with flow below seat 5.2. Operating limits Operating limits for medium temperature and operating pressure Operating limits for ambient and medium temperature Operating limits for seat seal Operating limits for optional versions 5.3. Electrical control and interfaces .... Interface diagram 6. Product design and assembly 17 6.2. Product assembly 7. Ordering information 20 7.2. Bürkert product filter 7.3. Ordering chart accessories Standard accessories Accessories cable Bürkert accessories 7.4. Bürkert Product Enquiry Form ...
3 | 22Visit product website 1. General technical data Note: AG2: Actuator size 2 with a nominal force of 1300 or 2500 N for seat size 15…50 AG3: Actuator size 3 with a nominal force of 7700 or 10000 N for seat size 40…80 Product properties Dimensions Further information can be found in chapter “4. Dimensions” on page 6 Material Further information can be found in chapter “3. Materials” on page 5 Design Angle seat on/off valve Nominal diameter DN 15…80, NPS ½…3 Safety setting in case of power failure With SAFEPOS energy-pack: open, closed or freely programmable Without SAFEPOS energy-pack: blocked in last position Flow direction Against closing direction (below seat) Weight Actuator depending on version up to: AG2: 5.5 kg AG3: 16 kg (Total weight including valve body depending on port connection) Performance data Operating pressure 0…25 bar(g) (see “5.1. Fluidic data” on page 13 Vacuum version up to - 0.9 bar(g) (optional) Nominal pressure PN 25 (DIN EN 1333), Class 150 (DIN EN 1759) KV value 5.0…140 m3/h (see “5.1. Fluidic data” on page 13) Closing time1.) AG2: 2.3…6.6 s AG3: 8.7 s (Depending on travel speed, stroke and operating conditions) Travel speed1.) 6 mm/s (for AG2 actuator force 1300 N) 4 mm/s (for AG2 actuator force 2500 N) 3 mm/s (for AG3 actuator load 7700 N and 10000 N) (Depending on operating conditions) Electrical data Operating voltage 24 V DC ± % (max. residual ripple 10 Operating current1.) AG2: Max. 3 A (at max. load and including 1 A charging current of the optional SAFEPOS energy-pack). At minimum operating temperature additionally 2 A AG3: Max. 5 A (at max. load and including charging current of the optional SAFEPOS energy-pack). At minimum operating temperature additionally 6 A Protection class (DIN EN 61140) 3 Duty cycle 100 Standby consumption1.) 2…4 W Communication and control Standard signals (analogue) 0…5 V (log. 0) 10…30 V (log. 1) Fieldbus (digital) Bürkert system bus (büS) (Standard) CANopen (optional) EtherNet/IP, PROFINET, Modbus/TCP (optional via integrated gateway) Media data Process medium Steam, neutral gases, water, alcohols, oils, fuels, hydraulic fluids, salt solutions, lyes, organ- ic solvents, oxygen (optional) Medium temperature - 40…+ 230 °C (see “5.2. Operating limits” on page 14 Viscosity Up to 600 mm²/s Process/Port connection & communication Port connection2.) Welded connection DIN EN ISO 1127/ISO 4200/DIN11866 B DIN 11850 2/DIN 11866 A ASME BPE/DIN 11866 C SMS 3008 Clamp connection DIN 32676 B (pipe ISO 4200) DIN 32676 A (pipe DIN 11850 2) ASME BPE Threaded connection G (EN ISO 228 Rc (ISO 7/1/DIN EN 10226 NPT (ASME B 1.20.1)
4 | 22Visit product website Electrical connection Actuator Terminal strip with cable gland, 2 x M20 (only AG2) or
2 M12 circular plugs, 5-pin and 8-pin
Fieldbus gateway 2 M12 circular sockets, 4-pin (only with Industrial Ethernets) Approvals and certificates Conformity Food EGV 1935/2004 FDA (optional) Approval Explosion protection ATEX/IECEx (optional) (see “2. Approvals” on page 4 cULus Cert. No. 238179 (optional) (only AG2) (see “2. Approvals” on page 4 Ignition protection class II 3G Ex ec IIC T4 Gc II 3D Ex tc IIIC T135 °C Dc Detergent resistance According to Ecolab test method: R&D/P3-E No. 40 Environment and installation Ambient temperature - 25…+ °C (only without additional modules) (De-rating see “Operating limits for ambient and medium temperature” on page 15) Degree of protection IP65/IP67 (DIN EN 60529), NEMA 4X Installation position Any, preferably actuator face up 1.) All values refer to a supply voltage of 24 V at 25 °C. 2.) Others on request 2. Approvals Approvals/ Conformity/ Certificate1.)
Description
Materials in contact with medium conform to EC regulation 1935/2004 Materials in contact with medium conform to FDA (optional) Drinking water Suitable for use with drinking water according to KTW, W270 (optional) Oxygen Suitable for use with gaseous oxygen (optional) Explosion proof As category 3 device suitable for zone 2/22 (optional) ATEX II 3G Ex ec IIC T4 Gc II 3D Ex tc IIIC T135 °C Dc IECEx Ex ec IIC T4 Gc Ex tc IIIC T135 °C Dc Safety requirements UL-listed cULus Cert. No. 238179 (optional) (only AG2) Detergent resistance Material compatibility tested with common Ecolab products and certified according to Ecolab test method: R&D/P3-E No. 40 Standards Description Field device for integration into the EDIP platform via Bürkert system bus (büS)
5 | 22Visit product website 3. Materials 3.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check 3.2. Material specifications Note: The Type 3320 angle seat valve is supplied with various port connections (thread, welded and clamp connections). These connec- tions are not shown. They are the same material as the valve body. AG2 No. Component Material
1 Blind cover/Gateway
PPS (Standard), Stainless steel 1.4301 (for ATEX/IECEx)
2 Actuator cover PPS
3 Seal EPDM
4 Actuator housing Aluminium powder coated
6 Seal EPDM
7 Actuator base PPS
No. Component Material PPS (Standard), Stainless steel 1.4301 (for ATEX/IECEx)
2 Actuator cover PC
5 SAFEPOS energy pack PC
7 Actuator base Stainless steel 1.4308
6 | 22Visit product website No. Component Material 1 Spindle Stainless steel 1.4401 (316) /1.4404 (316L)
2 Spindle seal PTFE V-seals (filled) with spring compensation
3 Spindle guidance PEEK or Stainless steel 1.4404 (316L) 4 Packing gland tube Stainless steel 1.4401 (316)
5 Seal valve body Graphite or PTFE
6 Swivel plate Stainless steel 1.4401 (316)/1.4404 (316L)
7 Valve seat seal PTFE or PEEK sealing washer
8 Valve body Stainless steel CF3M
- Dimensions 4.1. Actuator AG2 Note: Dimensions in mm, unless otherwise stated 130 max. 37 170 205 240 187 315 388 351 318 max. 23 73 Optional: integrated fieldbus gateway
7 | 22Visit product website 45° Nominal diameter (Pipe) Height/Width1.) DN NPS H1/B1 Standard version H2/B22.) Fieldbus version (KOMM ≠ G, N, L)) 15 ½ 311 362 20 ¾ 319 369 25 1 321 372 32 1¼ 330 381 40 1½ 333 384 50 2 367 418 1.) Dimensions without tight-closing function: in closed position the actuator additionally lifts by approx. 2 mm. Body with threaded connection. 2.) Optional: integrated fieldbus gateway
8 | 22Visit product website AG3 Note: Dimensions in mm, unless otherwise stated 187 14 max. 396 468 264 143
9 | 22Visit product website 45° H2*) B1*) B2*) H1*) Nominal diameter (Pipe) Height/Width1.) DN NPS H1/B1 Standard version H2/B22.) Fieldbus version (KOMM ≠ G, N, L)) 40 1½ 439 479 50 2 454 494 65 2½ 467 507 1.) Dimensions without tight-closing function: in closed position the actuator additionally lifts by approx. 2 mm. Body with threaded connection. 2.) Optional: integrated fieldbus gateway
10 | 22Visit product website 4.2. Body with threaded connection Note: Dimensions in mm, unless otherwise stated D CME SW LM Nominal diameter (Pipe) G (DIN ISO 228 - 1), NPT (ASME B 1.20.1), Rc (ISO7 - 1) D E CM LM SW DN NPS G NPT Rc 15 ½ 14 13.7 13.2 24 65 27 20 ¾ 16 14.0 14.5 27 75 34 25 1 18 16.8 16.8 29.5 90 41 32 1¼ 16 17.3 19.1 36 110 50 40 1½ 18 17.3 19.1 35 120 55 50 2 24 17.6 23.4 45 150 70 65 2½ 26 23.7 26.7 57 185 85 80 3 28 30.5 29.8 71 220 100
11 | 22Visit product website 4.3. Body with welded connection Note: Dimensions in mm, unless otherwise stated CS DS LS WS ES Nominal diameter (Pipe) DIN EN ISO 1127 ISO 4200 DIN 11866 B DIN 11850 2 DIN 11866 A DN ES CS LS ØDS WS ES CS LS ØDS WS 15 19 34 100 21.3 1.6 19 34 100 19 1.5 20 20 39 115 26.9 1.6 20 39 115 23 1.5 25 26 43 130 33.7 2.0 26 43 130 29 1.5 32 26 45 145 42.4 2.0 26 45 145 35 1.5 40 26 49 160 48.3 2.0 26 49 160 41 1.5 50 26 50 175 60.3 2.0 26 50 175 53 1.5 65 26 50 210 76.1 2.0 (2.3) 26 50 210 70 2 Nominal diameter (Pipe) ASME BPE DIN 11866 C NPS ES CS LS ØDS WS ½ 30 46 135 12.7 1.65 ¾ 30 52 145 19.05 1.65 1 30 51 152 25.4 1.65 1½ 30 60 182 38.1 1.65 2 30 64 210 50.8 1.65 2½ 26 56 230 63.5 1.65
12 | 22Visit product website 4.4. Body with clamp connection Note: Dimensions in mm D1C D2C SC LC CC Nominal diameter (pipe) Clamp: DIN 32676 B Pipe: EN ISO 1127 1 / ISO 4200 / DIN 11866 B Clamp: DIN 32676 A (DN 15 similar DIN 32676 B) Pipe: DIN 11850 2 / DIN 11866 A DN LC CC ØD C ØD2 C SC LC CC ØD1 C ØD2 C SC 65 265 77.5 91 76.1 2.0 265 78 91 70 2.0 Nominal diameter (pipe) Clamp: ASME BPE Pipe: ASME BPE / DIN 11866 C NPS LC CC ØD1 C ØD2 C SC ½ 130 49.0 25.0 12.7 1.65 ¾ 150 56.5 25.0 19.05 1.65 1 160 58.0 50.5 25.4 1.65 1½ 200 69.0 50.5 38.1 1.65 2 230 77.5 64.0 50.8 1.65 2½ 286 83 77.5 63.5 1.65
13 | 22Visit product website 5. Performance specifications 5.1. Fluidic data Overview of flow characteristics with flow below seat Note: KV value [m3/h]: Measured with water acc. to DIN EN 60534 - 2 - 4 Operating limits, see “5.2. Operating limits” on page 14 Nominal diameter (Pipe) Actuator force1.) Operating pressure KV value Seat seal PTFE (up to + 130 °C) PEEK (up to + 230 °C) DN NPS [N] [bar(g)] [m3/h] 15 ½2.) 1300 25 25 5 20 ¾2.) 11 25 12.) 18 32 1¼2.) 1300 16 16 31 2500 25 25 40 1½2.) 1300 10 10 42 2500 18 18 7700 – 25 50 22.) 1300 6 6 62 2500 10 10 7700 – 25 65 2½2.) 10000 – 25 95 80 32.) 10000 – 17 140 1.) AG2: Actuator size 2 with a nominal force of 1300 or 2500 N AG3: Actuator size 3 with a nominal force of 7700 or 10000 N 2.) Deviation for line connections according to ASME BPE: the next larger nominal connection size is used, e.g. NPS 1 instead of NPS ¾
14 | 22Visit product website 5.2. Operating limits Operating limits for medium temperature and operating pressure The operating range of Bürkert process valves is in addition to the maximum operating pressures limited by the nominal pressure according to the relevant standard. Operating limits for PN25 acc. to DIN EN 12516-1 Operating limits for Class 150 acc. to ASME B16.34 Operating limits for flange 10K acc.to JIS B 2220 Saturated steam curve for water -40 100 120 140 160 200 220 -0,9 0 5 10 15 20 25 Application limits of operating pressure and medium pressure Medium temperature [°C] Operating pressure [bar(g)] Low temperature version required High temperature version required -10 185 14 19 Saturated steam curve Standard -20 230
15 | 22Visit product website Operating limits for ambient and medium temperature The maximum permissible temperature for the environment and the medium are dependent on each other. The maximum allowable temperature curves of different device variants can be seen in the temperature chart. The curves were determined for maximum operating conditions (max. operating pressure and motor power). For deviating operating conditions an individual verification can be performed. Please contact your Bürkert office for more information. AG2 0 20 60 100 140 180 20040 80 120 160 220 230 Medium temperature [°C] Ambient temperature [°C] No. Description
1 Device without module
2 Device with SAFEPOS energy-pack or fieldbus gateway
Medium temperature [°C] Ambient temperature [°C] 200 180 200 220 230 No. Description
2 Device with SAFEPOS energy-pack
3 Device with fieldbus gateway
16 | 22Visit product website Operating limits for seat seal PTFE is used for max. medium temperature < 130 °C. If the maximum medium temperature temporarily or permanently exceeds 130 °C, then PEEK as a seal material is the appropriate solution. Operating limits for optional versions High temperature version By adapting the spindle sealing this version is suitable for applications with steam, neutral gases and other heat transfer mediums up to 230 °C. Drinking water version Materials in contact with the medium are tested for suitability with drinking water up to 85 °C. Vacuum version Without leakage bore, this design is suitable for pressures down to - 0.9 bar(g). Low temperature version Suitable for minimum medium temperatures down to - Version for oxygen Non-metallic materials in contact with the medium are tested for suitability with oxygen. Suitable for operating pressures up to 20 bar(g) and medium temperatures up to 60 °C. 5.3. Electrical control and interfaces Interface diagram The position of the actuator is controlled according to the digital input. The selection is made either by an external standard signal or via a fieldbus (digital). Inputs and outputs: 1 digital input, 2 digital outputs Interface: Cable gland with connection terminal (only AG2) M12 circular plug-in connectors (optional) Electro- motor valve
2 Digital outputs
24 V PNP
Note: Optional outputs are represented as a broken line. Communication Fieldbus büS / CANopen Digital input
24 V DC
Digital input 0…5 V = log “0", 10…30 V = log “1" inverted input reversed accordingly Digital output (optional) Current limitation 100 mA Communication Communication interface (büS) Connection to PC via USB büS interface set (connection terminals, circular plug-in connector or büS service interface) Communication software (büS) Bürkert Communicator, see Type 8920
17 | 22Visit product website 6. Product design and assembly 6.1. Product features Note More detailed information can be found in the operating instructions Type 3320 User interface The basic functions are operated by 4 DIP switches and 2 push buttons. These are located under the blind cover which can be removed manually by turning. Through the büS service access, the device can also be configured in detail with the Bürkert communicator software. For this, the optional USB- büS interface kit is required. DIP switch* SIM card CLOSE button* büS Service interface OPEN button * Mechanical manual control Blind cover dismantled Actuation Mechanical manual control: The manual override for mechanical movement of the valve is located for AG2 under the blind cover or display module and for AG3 under the pressure compensation element. It ensures that the actuator can be operated even if the power supply fails. Electrical control via operating elements: The electrical manual override for the procedure is carried out via two buttons under the blind cover. Display elements Display: 360° LED light ring: A clearly visible 360° LED ring is attached to the blind cover or display module to indicate the device status, the valve end position and the operating status. The LED light ring lights up, blinks or flashes into one or changing colours, depending on the LED mode set LED light ring Valve open Valve closed Mechanical position indicator Mechanical position indicator: The mechanical position indicator shows the current valve position even if the supply voltage fails. Data transmission (optional) SIM card (optional): With the optionally available SIM card, device-spe- cific values and user settings can be stored and quickly transferred to another device. SIM card holder büS service interface: The büS service interface connects the device with the Communicator software on a PC, laptop or smartphone. From there a configuration of the device or error diagnosis can be carried out. büS service interface Connection for CAN adapter or USB-büS interface set
18 | 22Visit product website Safety position via energy storage (optional) AG2 AG3 The safety starting positions in case of power inter- ruption is realized with the optional energy storage SAFEPOS energy-pack. The desired position is set via the menu. In addition to the end positions (open/ closed), any desired intermediate position can be defined here. The energy storage has a lifespan of up to 10 years, depending on the operating condi- tions. The power of the energy storage is monitored and a warning is displayed to indicate its life is com- ing to an end. The storage device is designed as a plug-in module to facilitate replacement. Without energy storage, the valve remains in the last position it was in. The energy storage device is fully charged and ready for operation after a maximum of 120 seconds (depending on the operating conditions). The energy storage device cannot be retrofitted in the field. SAFEPOS energy-pack Fieldbus: EtherNet/IP, PROFINET, Modbus TCP (optional) The fieldbus gateway for EtherNet/IP, PROFINET and Modbus TCP is integrated in an additional module. It has 2 fieldbus connections with 4-pin M12 circular sockets. The interfaces for the fieldbus connection and the status LEDs are located under the gateway housing cover. If there is a need for it to be include in a network then the configuration of the Ethernet can be performed via the web server. The gateway cannot be retrofitted in the field. Fieldbus gateway Fieldbus M12 connection (2 Port Ethernet Switch)
19 | 22Visit product website 6.2. Product assembly The electromotive linear drive consists of a brushless DC motor, a gear and a spindle system that transmits the force to the pendu- lum plate. The integrated control electronics are controlled either via standard signals (digital) or via a fieldbus (digital). It is designed to provide optimum efficiency. At the same time, it keeps the valve sealed and in position even at the maximum specified medium pressure in a powerless standstill. An optional energy storage device (SAFEPOS energy-pack) is available for the device. If the supply voltage fails, it supplies the actuator with the energy required to move the valve into the desired position; this is set in the menu. The valve position can be changed manually in 2 ways. Either via the electrical manual control or via a mechanical manual control if no supply voltage is available. The device can be set and operated via 2 capacitive keys and 4 DIP switches. In addition there is always the possibility to operate the device via the büS service interface and using the “Bürkert Communicator” software. The intelligent process valve Type 3320 offers the operator options for process monitoring, valve diagnostics and preventive mainte- nance. Internal measurements of the operating status are evaluated and issued as warnings or error messages, if necessary. These indicate, for example, impermissible ambient and process conditions, functional deviations of components or the status of the energy storage device. AG2 Actuator housing Actuator cover Transparent window with position indicator Body connection (with wrench connection) Numbers for indicating the direction of flow Angle seat valve body Port connection Relief bore FE functional ground Actuator base Blind cover with status indicator and bayonet catch Electrical connections (circular plug-in connector or cable gland) Do not unscrew pressure compensation element!
20 | 22Visit product website AG3 Body connection (with wrench connection) Port connection Angle seat valve body Electrical connections circular plug-in connector SAFEPOS energy-pack (optional) Pressure compensation element / access for mechanical manual operation FE functional groundRelief bore Actuator housing Actuator cover Transparent window with position indicator Actuator base Blind cover with status indicator and bayonet catch 7. Ordering information 7.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
21 | 22Visit product website 7.3. Ordering chart accessories Standard accessories Description Article no. SIM card for data transmission between devices 291773 Holding device for port connection DN 15…40 693770 Holding device for port connection DN 50 693771 Plastic blind cover 277881 Energy storage SAFEPOS energy-pack (AG2) 285834 Energy storage SAFEPOS energy-pack (AG3) 20046438 Accessories cable Note: For connection to a büS/CANopen network see cabling guide Description Article no. Connection cable with M12 socket, 4-pin, (length 5 m) for operating voltage (without communication) 918038 Connection cable with M12 socket, 5-pin, L coded (length 5 m) for operating voltage AG3 (without communication) 20010840 Connection cable with M12 socket, 8-pin, (length 2 m) for input and output signals 919061 Bürkert accessories Note: For connection to a büS/CANopen network see cabling guide Detailed accessory tables can be found in the cabling guide. Description Article no. Software Bürkert Communicator, Type 8920 Type 8920 büS stick set 1 (including power supply unit, bus-stick, terminating resistor, Y-distributor, 0.7 m cable with M12 connector) 772426 büS stick set 2 (including bus-stick, terminating resistor, Y-distributor, 0.7 m cable with M12 connector) 772551 büS adapter for büS interface set (M12 on büS service interface Micro-USB) 773254 7.4. Bürkert Product Enquiry Form Bürkert Product Enquiry Form – Your enquiry quickly and compactly Would you like to make a specific product enquiry based on your technical require- ments? Use our Product Enquiry Form for this purpose. There you will find all the relevant information for your Bürkert contact. This will enable us to provide you with the best possible advice. Fill out the form now
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -
74653 Künzelsau
www.burkert.com