https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 1 / 6 High-current terminal block - PTPOWER 150 - 3215000 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) High-current terminal block, Connection method: Power-Turn connection, Number of positions: 1, Cross section: 50 mm² - 150 mm², AWG: 1/0 - 300 kcmil, Width: 31 mm, Color: gray, Mounting type: NS 35/15 Product Features Quick and easy connection is now also possible for large conductors with the high-current terminal block The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors The compact design enables wiring in a confined space In addition to using the existing test connection, pick-off terminal blocks can be connected, each of which can also accommodate two test cables Key Commercial Data Packing unit 1 pc Minimum order quantity 3 pc Weight per Piece (excluding packing) 340.0 g Custom tariff number 85369010 Country of origin Poland Technical data General Number of levels 1 Number of connections 2 Nominal cross section 150 mm² Color gray Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 8 kV Degree of pollution 3 Overvoltage category III
https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 2 / 6 High-current terminal block - PTPOWER 150 - 3215000 Technical data General Insulating material group I Connection in acc. with standard IEC 60947-7-1 Maximum load current 309 A (with 150 mm² conductor cross section) Nominal current IN 309 A Nominal voltage UN 1500 V Open side panel No Number of positions 1 Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection guaranteed Finger protection guaranteed Result of surge voltage test Test passed Surge voltage test setpoint 14.8 kV Result of power-frequency withstand voltage test Test passed Power frequency withstand voltage setpoint 6 kV Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed Result of bending test Test passed Bending test rotation speed 10 rpm Bending test turns 135 Bending test conductor cross section/weight 50 mm² / 9.5 kg 150 mm² / 15 kg Tensile test result Test passed Conductor cross section tensile test 50 mm² Tractive force setpoint 236 N Conductor cross section tensile test 150 mm² Tractive force setpoint 427 N Result of tight fit on support Test passed Tight fit on carrier NS 35/15-2,3 UNGELOCHT Setpoint 15 N Result of voltage-drop test Test passed Requirements, voltage drop ≤ 3.2 mV Result of temperature-rise test Test passed Short circuit stability result Test passed Conductor cross section short circuit testing 150 mm² Short-time current 18 kA Result of aging test Test passed Ageing test for screwless modular terminal block temperature cycles 192
https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 3 / 6 High-current terminal block - PTPOWER 150 - 3215000 Technical data General Result of thermal test Test passed Proof of thermal characteristics (needle flame) effective duration 30 s Oscillation, broadband noise test result Test passed Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03 Test spectrum Service life test category 1, class B, body mounted Test frequency f1 = 5 Hz to f2 = 150 Hz ASD level 0.964 (m/s /Hz Acceleration 0.58 g Test duration per axis 5 h Test directions X-, Y- and Z-axis Shock test result Test passed Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03 Shock form Half-sine Acceleration 5 g Shock duration 30 ms Number of shocks per direction 3 Test directions X-, Y- and Z-axis (pos. and neg.) Relative insulation material temperature index (Elec., UL 746 B) 130 °C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C Static insulating material application in cold -60 °C Dimensions Width 31 mm Length 116.4 mm Height NS 35/15 116.5 mm Connection data Connection method Power-Turn connection Connection in acc. with standard IEC 60947-7-1 Conductor cross section solid min. 50 mm² Conductor cross section solid max. 150 mm² Conductor cross section AWG min. 1/0 Conductor cross section AWG max. 300 kcmil Conductor cross section flexible min. 50 mm² Conductor cross section flexible max. 150 mm² Min. AWG conductor cross section, flexible 1/0 Max. AWG conductor cross section, flexible 300 kcmil Conductor cross section flexible, with ferrule without plastic sleeve min. 50 mm²
https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 4 / 6 High-current terminal block - PTPOWER 150 - 3215000 Technical data Connection data Conductor cross section flexible, with ferrule without plastic sleeve max. 95 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 50 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 95 mm² Cross section with insertion bridge solid min. 50 mm² Cross section with insertion bridge, solid max. 150 mm² Cross section with insertion bridge stranded min. 50 mm² Cross section with insertion bridge, stranded max. 150 mm² Cross section with insertion bridge stranded, with ferrule without plastic sleeve min. 50 mm² Cross section with insertion bridge stranded, with ferrule without plastic sleeve max. 95 mm² Cross section with insertion bridge stranded, with ferrule without plastic sleeve min. 50 mm² Cross section with insertion bridge stranded, with ferrule with plastic sleeve max. 95 mm² Cross section with insertion bridge, solid max. 150 mm² Cross section with insertion bridge, stranded max. 150 mm² Stripping length 40 mm Internal cylindrical gage B14 Standards and Regulations Connection in acc. with standard IEC 60947-7-1 Flammability rating according to UL 94 V0 Classifications eCl@ss eCl@ss 5.1 27141120 eCl@ss 6.0 27141120 eCl@ss 8.0 27141120 eCl@ss 9.0 27141120 ETIM ETIM 4.0 EC000897 ETIM 5.0 EC000897 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410
https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 5 / 6 High-current terminal block - PTPOWER 150 - 3215000 Classifications UNSPSC UNSPSC 12.01 39121410 UNSPSC 13.2 39121410 Approvals Approvals Approvals EAC / LR / BV / GL / UL Recognized / cUL Recognized / cULus Recognized Ex Approvals Approvals submitted Approval details EAC LR BV GL UL Recognized B C mm²/AWG/kcmil 2-300 2-300 Nominal current IN 270 A 270 A Nominal voltage UN 1000 V 1000 V
https://www.phoenixcontact.com/us/products/3215000 02/19/2016 Page 6 / 6 High-current terminal block - PTPOWER 150 - 3215000 Approvals cUL Recognized C mm²/AWG/kcmil 2-300 Nominal current IN 270 A Nominal voltage UN 1000 V cULus Recognized Drawings Circuit diagram Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com