310 MORSE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

The Specialist In Drum Handling Equipment

310 Series

Copyright 2022 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 1 MADE IN USA service@morsedrum.com 103 Kuhn Rd. Syracuse, NY, 13208 USA morsedrum.com (315) 437-8475 Mixing in a Closed Drum Means Less Hazards Using a Morse Drum Rotator eliminates spills, splashing of dangerous contents on workers, and risk of contamination. Now you can get the benefits of mixing inside closed shipping drums and have the machine do the work of loading and unloading itself! Morse 310 Series models accept the drum upright at floor level. The user controls hydraulic tilting action that raises the drum into position for rotating. A second valve allows the operator to start and stop the hydraulic motor that drives rotation. You minimize time, labor and operating cost by eliminating extra moves required for getting drum into mixing position. Rotate various sized drums, weighing up to 800 Lb. (363 kg) at 5 to 20 RPM. Install all Morse Rotators in accordance with OSHA requirements for enclosure and safety interlock, etc. so the rotator automatically turns off when enclosure door is opened. One way to accomplish this is with a Morse enclosure with safety interlock. For OSHA compliance, see OSHA subpart O.1910.212(a)(4) “Barrels, containers, and drums. Revolving drums, barrels, and containers shall be guarded by an enclosure which is interlocked with the drive mechanism, so that the barrel, drum, or container cannot revolve unless the guard enclosure is in place.” Power connections and motor controls must comply with applicable codes. Tilt-To-Load Drum Tumbler shown with Controls and Enclosure with Safety Interlock (sold separately)

  • Rotate closed plastic, steel, or fiber drum
  • Thorough corner-over-corner mixing action
  • Save time, labor and money
  • Use a separate drum for each batch
  • No container to purge between batches Load drum into lowered drum holder with hinged ratchet plate and the top clamps both open. Model 152 Drum Truck is shown loading drum. Can also load with Model 81 Drum Spotter or Model 92 Below-Hook Drum Lifter. Secure drum in the rotator using the web strap and ratchet, and tightening the top clamps (inset). Turn the motor on to activate the hydraulics. Raise the drum to the top position by raising the TILT control valve. To begin rotating, raise the ROTATE control valve. 1. Load Upright Drum at Floor Level 2. Secure Drum in Holder 3. Power Lift and Rotate Tilt-To-Load Drum Tumblers
  • Tumble a plastic, steel or fiber drum:
  • 29” to 37” (74 to 94 cm) tall
  • 18” to 23.5” (46 to 60 cm) in diameter
  • Rotate your drum at:
  • 5 to 20 RPM for 60Hz or Air models
  • 4 to 16 RPM for 50Hz models
  • Capacity:
  • 800 Lb. (363 kg) Full Drum
  • 400 Lb. (181 kg) Half-Full Drum Half-full Capacity is an indication of the capacity for tilting an unbalanced, bottom-heavy drum. A partially full drum with an unbalanced and shifting load is harder to tilt than a full drum. Optional Hydraulic Oil Cooler for applications requiring a higher service factor, such as longer run times or operating in areas with high ambient temperature.
  • Factory Installed Option # 5014i-P on AC model
  • Kit # 5014KIT-P for customer to install on AC model Tilt-To-Load Drum Tumblers Feature Power-Tilt to Enable Easy, Floor-Level Loading

The Specialist In Drum Handling Equipment Website: morsedrum.com Copyright 2018 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 2 Dimensions

morsedrum.com Copyright 2022 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 3 The Specialist In Drum Handling Equipment

morsedrum.com Copyright 2022 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 4 The Specialist In Drum Handling Equipment Tilt-To-Load Drum Tumblers Control Packages See Page 3 Guard Enclosure Kits See Page 4 Model # Drum RPM (22.5” Dia.) Motor Information Kit # Motor Style HP Phase Motor Voltage Amp Draw Option # 310-1 5 to 20 60 Hz TEFC 2 1 115 23 † CP-310-1-115 * GEK-310-1208 12 CP-310-1-230 * 230 11.5 310-3 5 to 20 60Hz TEFC 2 3 208 5.3 CP-310-3-230 * GEK-310-3230 5.0 460 2.5 CP-310-3-460 * 310-3-575 5 to 20 60Hz TEFC 2 3 575 2.0 CP-310-3-575 * GEK-310-3 310-E1 5 to 20 60Hz Explosion proof ** 2 1 115 21 † CP-310-E1-115 * GEK-310-E1208 11.5 CP-310-E1-208 * 230 10.5 CP-310-E1-230 * 310-E3 5 to 20 60Hz Explosion proof ** 2 3 208 5.3 CP-310-E3-208 * GEK-310-E3230 5.0 CP-310-E3-230 * 460 2.5 CP-310-E3-460 * 310-A 5 to 20 Air Motor * - - - - Air Controls are included with model 310-A * GEK-310-A Models for Countries with 50Hz Power Supply 310-1-50 4 ro 16 50Hz TEFC 2 1 220 9.7 CP-310-1-220-50 * GEK-310-1 310-3-50 4 to 16 50Hz TEFC 2 3 230 5.0 CP-310-3-230-50 * GEK-310-3 400 2.9 CP-310-3-400-50 * 310-E1-50 4 to 16 50Hz Explosion proof ** 2 1 220 9.8 CP-310-E1-220-50 * GEK-310-E1 310-E3-50 4 to 16 50Hz Explosion proof ** 2 3 230 5.5 CP-310-E3-230-50 * GEK-310-E3 400 3.2 CP-310-E3-400-50 * * ONLY NON-Explosion Proof AC Control Packages include a pre-wired control box. Explosion-proof Control Packages have no wiring from the NEMA 7/9 control box to the motor. Please consult an electrician to complete the wiring in accordance to local code. Explosion-proof motors are rated for Class I Group D, and Class II Groups F and G. * Air powered model requires plant air at 50 to 60 PSI and flowing at a rate of 60 SCFM. Filter, Regulator, Lubricator and valve are included with drum Tumbler model 310-A. † Requires 30 Amp circuit, and can have amp spikes higher than that. Crates for Export Export Crate # Description 3212X-P Fully Enclosed Crate for Export of (1) Tilt-To-Load Drum Tumbler 4463X-P Fully Enclosed Crate for Export of (1) Guard Enclosure Kit 5480X-P Fully Enclosed Crate for Export of (1) Tilt-To-Load Drum Tumbler, (1) Control Package and (1) Guard Enclosure Kit

morsedrum.com Copyright 2022 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 5 The Specialist In Drum Handling Equipment Explosion Proof AC Control Package (sold separately) NEMA 7/9 for Hazardous Areas Includes Control Box with:

  • Start and Stop Buttons
  • Wire terminals for external connection of safety interlock switch Control Package # Description Minimum Power Supply Required Power Supply CP-310-1-115 * Control Package for 310-1 30 Amp 1-Phase 115V 60Hz CP-310-1-230 * Control Package for 310-1 15 Amp 1-Phase 230V 60Hz CP-310-1-220-50 Control Package for 310-1-50 15 Amp 1-Phase 220V 50Hz CP-310-3-230 * Control Package for 310-3 15 Amp 3-Phase 230V 60Hz CP-310-3-460 * Control Package for 310-3 10 Amp 3-Phase 460V 60Hz CP-310-3-230-50 Control Package for 310-3-50 10 Amp 3-Phase 230V 50Hz CP-310-3-400-50 Control Package for 310-3-50 10 Amp 3-Phase 400V 50Hz CP-310-3-575 Control Package for 310-3-575 10 Amp 3-Phase 575V 60Hz CP-310-E1-115 * Control Package for 310-E1, Explosion-Proof 30 Amp 1-Phase 115V 60Hz CP-310-E1-208 * Control Package for 310-E1, Explosion-Proof 15 Amp 1-Phase 208V 60Hz CP-310-E1-230 * Control Package for 310-E1, Explosion-Proof 15 Amp 1-Phase 230V 60Hz CP-310-E1-220-50 * Control Package for 310-E1-50, Explosion-Proof 15 Amp 1-Phase 220V 50Hz CP-310-E3-208 * Control Package for 310-E3, Explosion-Proof 15 Amp 3-Phase 208V 60Hz CP-310-E3-230 * Control Package for 310-E3, Explosion-Proof 15 Amp 3-Phase 230V 60Hz CP-310-E3-230-50 * Control Package for 310-E3-50, Explosion-Proof 15 Amp 3-Phase 230V 50Hz CP-310-E3-460 * Control Package for 310-E3, Explosion-Proof 10 Amp 3-Phase 460V 60Hz CP-310-E3-400-50 * Control Package for 310-E3-50, Explosion-Proof 10 Amp 3-Phase 400V 50Hz Select the appropriate Control Package for each model, and your power supply. Use power controls to start and stop drum rolling. The control mast can be positioned outside the Safety Enclosure on either the left or right side, or at the back of Drum Tumbler. Includes Control Box with:
  • Timer adjusts from a few seconds to 16 hours
  • Start and Stop Buttons
  • Red Emergency Stop Button
  • Lockable Main Disconnect to shut off and lock out power to the unit
  • Wire terminals for external connection of safety interlock switch AC Control Package (sold separately) NEMA 4/12 for NON-Hazardous Areas Control Packages (sold separately) Air Controls are Included with Model 310-A Air Controls Include
  • Filter, Regulator and Lubricator (FRL)
  • On / Off Valve

morsedrum.com Copyright 2022 - Morse Mfg. Co., Inc. Spec Sheet F310 (Updated 23 Aug., 2022) 6 The Specialist In Drum Handling Equipment Guard Enclosure Kit # Description Gate Switch GEK-310-1 Fits Tilt-To-Load Drum Tumbler with 1-phase electric motor AC GEK-310-3 Fits Tilt-To-Load Drum Tumbler with 3-phase electric motor AC GEK-310-E1 Fits Tilt-To-Load Drum Tumbler with Explosion-proof 1-phase electric motor AC GEK-310-E3 Fits Tilt-To-Load Drum Tumbler with Explosion-proof 3-phase electric motor AC GEK-310-A Fits Tilt-To-Load Drum Tumbler with Air motor Air Guard Enclosure Kits with Safety Interlock (sold separately) Guard Enclosures for Morse Tilt-To-Load Drum Tumblers have a safety interlock to automatically shut off the Drum Tumbler when the gate is opened. Open the enclosure gate, place your drum onto the drum Tumbler, then close the gate to allow operation. Connections are included for air powered model only. Morse Control Packages (page 3) provide controls and connections for AC models. All Morse Control Packages (see page 3) include a low-voltage transformer and wire terminals required to connect the external safety interlock switch of these Guard Enclosure Kits. Morse Control Packages and Enclosures meet OSHA regulations ONLY when installed properly with safety interlock. Comply with OSHA Requirements with a Morse Guard Enclosure Kit (Sold Separately) Install all Morse Rotators in accordance with local requirements for enclosure and safety interlock, etc. One way to accomplish this is with a Morse enclosure with safety interlock, so the rotator automatically turns off when enclosure door is opened. Power connections and motor controls must also comply with applicable local codes. For OSHA compliance in the USA, see OSHA subpart O.1910.212(a) (4) “Barrels, containers, and drums. Revolving drums, barrels, and containers shall be guarded by an enclosure which is interlocked with the drive mechanism, so that the barrel, drum, or container cannot revolve unless the guard enclosure is in place.” Outside Post-to-Post Dimensions of Enclosures L88” x W52” x H63.25” (224 x 132 x 161 cm) Guard Enclosure with safety interlock (shown with Drum Tumbler and Control Package each sold separately)