https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 1 / 6 Bolt connection terminal block - RBO 6 - 3075896 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Bolt connection terminal block, nom. voltage: 800 V, nominal current: 125 A, connection method: Bolt connection, number of connections: 2, number of positions: 1, cross section: 2.5 mm² - 35 mm², width: 17 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 32 Your advantages Compact connection with ring and fork-type cable lugs Mounting on standard DIN rails or directly in control boxes Isolator bridge bar for switchable cross connections Bridge shaft for potential distribution using standard screw bridges Key Commercial Data Packing unit 40 pc GTIN GTIN 4046356532853 Technical data General Number of positions 1 Number of levels 1 Number of connections 2 Potentials 1 Nominal cross section 35 mm² Color gray Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 8 kV Degree of pollution 3 Overvoltage category III Insulating material group I
https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 2 / 6 Bolt connection terminal block - RBO 6 - 3075896 Technical data General Maximum power dissipation for nominal condition 4.06 W Designation Level 1 above 1 below 1 Maximum load current 125 A (with 35 mm² conductor cross section) Nominal current IN 125 A Nominal voltage UN 800 V Open side panel No Result of surge voltage test Test passed Surge voltage test setpoint 9.8 kV Result of power-frequency withstand voltage test Test passed Power frequency withstand voltage setpoint 2 kV Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed Result of tight fit on support Test passed Tight fit on carrier NS 32/NS 35 Setpoint 10 N Result of voltage-drop test Test passed Requirements, voltage drop ≤ 3.2 mV Result of temperature-rise test Test passed Short circuit stability result Test passed Conductor cross section short circuit testing 35 mm² Short-time current 4.2 kA Result of thermal test Test passed Proof of thermal characteristics (needle flame) effective duration 30 s Oscillation, broadband noise test result Test passed Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03 Test spectrum Service life test category 1, class B, body mounted Test frequency f1 = 5 Hz to f2 = 150 Hz ASD level 1.857 (m/s /Hz Acceleration 0,8 g Test duration per axis 5 h Test directions X-, Y- and Z-axis Shock test result Test passed Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03 Shock form Half-sine Acceleration 5g Shock duration 30 ms Number of shocks per direction 3 Test directions X-, Y- and Z-axis (pos. and neg.) Relative insulation material temperature index (Elec., UL 746 B) 130 °C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 3 / 6 Bolt connection terminal block - RBO 6 - 3075896 Technical data General Static insulating material application in cold -60 °C Behavior in fire for rail vehicles (DIN 5510-2) Test passed Flame test method (DIN EN 60695-11-10) V0 Oxygen index (DIN EN ISO 4589-2) >32 % NF F16-101, NF F10-102 Class I 2 NF F16-101, NF F10-102 Class F 2 Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Smoke gas toxicity NFPA 130 (SMP 800C) passed Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Dimensions Width 17 mm End cover width 2.2 mm Length 80.8 mm Height NS 35/7,5 49.8 mm Height NS 35/15 57.3 mm Height NS 32 54.8 mm Pitch 17 mm Connection data Note Connection bolts Connection 1 level Connection method Bolt connection Screw thread M6 Tightening torque, min 3.2 Nm Tightening torque max 3.7 Nm Connection in acc. with standard IEC 60947-7-1 Conductor cross section solid min. 2.5 mm² Conductor cross section solid max. 35 mm² Conductor cross section flexible min. 2.5 mm² Conductor cross section flexible max. 35 mm² Min. AWG conductor cross section, flexible 12 Max. AWG conductor cross section, flexible 2 Conductor cross section flexible, with ferrule with plastic sleeve min. 2.5 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 35 mm² Cable lug connection according to standard DIN 46234 Min. cross section for cable lug connection 6 mm²
https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 4 / 6 Bolt connection terminal block - RBO 6 - 3075896 Technical data Connection data Max. cross section for cable lug connection 35 mm² Additional text only use with shrink sleeve Hole diameter, min. 6.5 mm Cable lug width, max. 15 mm Bolt diameter 6 mm Cable lug connection according to standard DIN 46237 Min. cross section for cable lug connection 2.5 mm² Max. cross section for cable lug connection 6 mm² Hole diameter, min. 6.5 mm Cable lug width, max. 11 mm Bolt diameter 6 mm Standards and Regulations Connection in acc. with standard CUL IEC 60947-7-1 Flammability rating according to UL 94 V0 Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings Circuit diagram Approvals Approvals Approvals CSA / UL Recognized / cUL Recognized / EAC / EAC / cULus Recognized Ex Approvals
https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 5 / 6 Bolt connection terminal block - RBO 6 - 3075896 Approvals Approval details CSA http://www.csagroup.org/services-industries/product-listing/ 13631 B C Nominal voltage UN 600 V 600 V Nominal current IN 115 A 115 A mm²/AWG/kcmil 12-2 12-2 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425 B C Nominal voltage UN 600 V 600 V Nominal current IN 115 A 115 A cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425 B C Nominal voltage UN 600 V 600 V Nominal current IN 115 A 115 A EAC EAC-Zulassung EAC RU C- DE.A*30.B.01742 cULus Recognized
https://www.phoenixcontact.com/pi/products/3075896 09/26/2019 Page 6 / 6 Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8
32825 Blomberg
Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com