3004 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Visit product website  DATA SHEET Type 2651  2/2 or 3/2-way Ball Valve, 2-Piece Type 2654  2/2-way ball valve 3-piece Type 2657  Ball Valve, manually-operated Type 2671  Butterfly valve Type 2674  Plastic butterfly valve Type TKU001  2/2-way compact flange ball valve Type 8804  Ball valve / butterfly valve with electrical rotary actuator Standard | EU | en | 202302 | 21 Explosion Proof Rotary Actuator - On/Off and control

  • Direct mounting for quarter-turn valves Manual override Corrosion resistant Adjustable limit switches ATEX II 2 GD Ex d II B T6 The electrical rotary actuator type 3004 is a compact, powerful and explosion proofed actuator system which provides a long service life. Materials and components have been chosen for a maintenance-free operation and ensure low thermal loading on the actuator. The modular design offers many options such as extra limit switches or potentiometers, to be added to the basic unit. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 3004 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 12Visit product website  Table of contents 1. General Technical Data 3 Materials 3. Dimensions 4 3.2. Motor 100, 150, 300 Nm 4. Device/Process connections 6 4.2. Multi-voltage or 24 V AC/DC with programmable analogue signal input or output 5. Product design and assembly 8 6. Ordering information 9 6.2. Bürkert product filter 6.3. Ordering chart Standard version without analogue signal input Control version with 4…20 mA, 0…20 mA or 0…10 V programmable analogue signal input or output 6.4. Ordering chart accessories Conversion sleeves Spare battery for actuators with electronic emergency reset Other accessories

3 | 12Visit product website  1. General Technical Data Product properties Dimensions Detailed information can be found in chapter “3. Dimensions” on page 4 Material Cover / Body Epoxy coated aluminium Axis / Screw Stainless steel Gear Stainless steel ISO Mounting Motor 25, 45, 75 Nm F05/F07 Motor 100, 150, 300 Nm F07/F10 Drive Motor 25 Nm Female star 17 mm; conversion sleeve star 17/11 mm enclosed Motor 45, 75 Nm Female star 17 mm; conversion sleeve star 17/14 mm enclosed Motor 100, 150, 300 Nm Female star 22 mm; conversion sleeve star 22/17 mm enclosed Manual override Motor 25, 45, 75 Nm By outgoing axis with return spring Motor 100, 150, 300 Nm By hand wheel Weight Motor 25, 45, 75 Nm 4 kg Motor 100, 150, 300 Nm 6 kg Mechanical limit stops Standard Optical position indicator Standard Performance data Torque 25, 45, 75, 100, 150 und 300 Nm Detailed information can be found in chapter “6. Ordering information” on page 9 Position angle 90° (± 5°) Actuating time (10…90 %) 7…50 sec. Detailed information can be found in chapter “6. Ordering information” on page 9 Options Rotation 180° or 270° 3 position actuator (for 180°) Feedback On/Off actuators: - Potentiometer 1K, 5K, or 10K - Analogue signal 4…20 mA Fail safe option* (on request) 2 extra limit switches Electrical data Operating voltage 100…240 V AC / 50…60 Hz oder 24 V AC/DC ± Limit switches 4 adjustable (2 for motor and 2 additional for feedback) max. 250 V AC/5 A Power consumption 45 W…85 W Voltage tolerance ± Analogue signals control version Input - 0…10 V / - 4…20 mA / - 0…20 mA Output - 0…10 V / - 4…20 mA / - 0…20 mA Motor protection Electronic torque limited Duty cycle At max. torque: 50 % of the time Control actuator: 50 % of max. torque Heating resistor 10 W Process/Port connection & communication Electrical connection 2 cable glands ISO 20 Environment and installation Installation position Do not mount the actuator upside down! Ambient temperature - °C…+ Degree of protection IP68

4 | 12Visit product website  2. Materials 2.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 3. Dimensions 3.1. Motor 25, 45, 75 Nm Note: Dimensions in mm ø 170 198 201 20 ø 70 ISO F07 4xM8 ø 50 ISO F05 4xM6

5 | 12Visit product website  3.2. Motor 100, 150, 300 Nm Note: Dimensions in mm ø 102 ISO F10 4xM10 ø 70 ISO F07 4xM8 18035 259 275 ø 170

6 | 12Visit product website  4. Device/Process connections 4.1. Multi-voltage or 24 V AC/DC standard version N Ph N Ph FC2 FC1 FCF FC0 4-6 5 7 C C A B D D T/E 1 2 3 4 1 2 3 4 T/E T/E 1 2 3 4 * * 3-points modulating mode On-Off mode Switch on = actuator opens Switch off = actuators closes POWER SUPPLY AND COMMAND FEEDBACK On OnOff Motor INDICATED VOLTAGE ON ACTUATOR:

24 V AC/DC or 100 - 240 V AC (120 - 350 V DC)

(see actuator label) SUGGESTED CUSTOMER WIRING INTERNAL ACTUATOR WIRING * Only for probe version Symbol Description FCO Open limit switch FCF Close limit switch FC1 Auxiliary 1 limit switch FC2 Auxiliary 2 limit switch

7 | 12Visit product website  4.2. Multi-voltage or 24 V AC/DC with programmable analogue signal input or output T/E FC2 FC1 FCF FC0 4-6 5 7 C B D D A C 17 18 18 17 N Ph N Ph 0-20 mA / 4-20 mA / 0-10 V 1 2 3 4 POWER SUPPLY: 100 - 240 V AC (120 - 350 V DC) Actuator power supply (see actuator label) POWER SUPPLY:

24 V AC/DC

Only for 100 - 240 V AC (120 - 350 V DC) INPUT FEEDBACK AUXILIARY FEEDBACK Motor * Only for probe version Symbol Description FCO Open limit switch FCF Close limit switch FC1 Auxiliary 1 limit switch FC2 Auxiliary 2 limit switch

8 | 12Visit product website  5. Product design and assembly 5.1. Product features Motor 25, 45, 75 Nm Motor 100, 150, 300 Nm 9.a 1 0 1 1 1 2 1 3 1 4 1 6 1 7 1 5 9.b 1 0 1 1 1 2 1 3 1 4 1 6 1 8 1 7 1 5 No. Element

1 Optical position indicator

2 Cover

3 Stainless steel screws

4 Motor

5 Power supply card

6 Gear box

7 O-ring

8 Gear

9.a Manual override 9.b Hand wheel

10 Housing

11 Identification label

12 Auxiliary limit switch terminal

13 Cams

14 Power supply terminal

15 Internal thread M20

1.5

16 Earth screw

17 Positioning card (only actuator with position control)

18 Mechanical limit stops

9 | 12Visit product website  6. Ordering information 6.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 6.3. Ordering chart Standard version without analogue signal input Note: For the actuator choice, we recommend a safety torque equal to 1.5 times of the valve maximal torque (2 times for the control version). Other regulating times and delay angles on request Drive stars Conversion adapter star Connection flange Torque 90° ravel Power consump- tion Voltage / Frequency Article no. [mm] [mm] [Nm] [s] [W] [V / Hz] 17 17/11 F05-F07 25 7 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181308  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181309  17/14 F05-F07 45 15 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181310  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181311  75 20 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181312  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181313  22 22/17 F07-F10 100 15 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181314  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181315  150 30 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181316  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181317  300 60 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 181318  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 181319  1.) The operating voltage mustn’t to fall below 11.5 V

10 | 12Visit product website  Control version with 4…20 mA, 0…20 mA or 0…10 V programmable analogue signal input or output Note: For the actuator choice, we recommend a safety torque equal to 1.5 times of the valve maximal torque (2 times for the control version). Other regulating times and delay angles on request Drive stars Conversion adapter star Connection flange Torque 90° ravel Power consump- tion Voltage / Frequency Article no. [mm] [mm] [Nm] [s] [W] [V / Hz] 17 17/11 F05-F07 25 15 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182324  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182326  17/14 F05-F07 45 15 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182327  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182330  75 20 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182335  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182384  22 22/17 F07-F10 100 15 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182385  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182386  150 30 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182388  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182390  300 60 45 100…240 V AC, / 50/60 Hz / 100…350 V DC 182392  15…30 V AC, 50/60 Hz / 12…48 V DC1.) 182394  1.) The operating voltage mustn’t to fall below 11.5 V Further versions on request Voltage Other voltages 6.4. Ordering chart accessories Conversion sleeves Description Article no. Conversion Sleeve star/square14/9 mm 665288  Conversion Sleeve star/square 14/11 mm 665289  Conversion Sleeve square/square 17/14 mm 665290  Conversion Sleeve star/square 17/14 mm 773348  Conversion Sleeve star/square 17/11 mm 773343  Conversion Sleeve square/square 22/19 mm 773836  Conversion Sleeve star/square 22/17 mm 684858  Conversion Sleeve star/star 22/14 mm 666684  Conversion Sleeve star/square 22/11 mm 773344  Conversion Sleeve star/square 27/22 mm 774594  Conversion Sleeve square/square 27/19 mm 774279  Conversion Sleeve square/square 27/17 mm 774193 

11 | 12Visit product website  Spare battery for actuators with electronic emergency reset Note: The battery must be replaced after max. 500 charging cycles or after 2 years at the latest. Depending on which condition is reached earlier. Additional information for Type 3004: The person who changes the battery must be trained and qualified to do modifications on ATEX products. Actuators that do not have an electronic emergency reset when delivered cannot be upgraded with this device at a later date. Type Version Torque [Nm] Article no.

3003 BB40 10…100 775335 

3004/5 BB40 25…300 774761  3004/5 BB40 600…2400 775337  Other accessories Description Article no. Key for adjusting the limit switches 679946 

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com