https://www.phoenixcontact.com/us/products/2902646 10/23/2014 Page 1 / 5 Power supply unit - TRIO-PS/ 1AC/ 5DC/10 - 2902646 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/10 A Product description TRIO POWER power supplies with standard functionality TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use. The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability. Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 800.0 GRM Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 40 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Noise immunity EN 61000-6-2:2005 Input data
https://www.phoenixcontact.com/us/products/2902646 10/23/2014 Page 2 / 5 Power supply unit - TRIO-PS/ 1AC/ 5DC/10 - 2902646 Technical data Input data Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 85 V AC ... 264 V AC (Derating < 90 V AC: 2.5 %/K) Short-term input voltage 300 V AC AC frequency range 45 Hz ... 65 Hz Current consumption 1 A (120 V AC)
0.5 A (230 V AC)
Nominal power consumption > 12 V constant capacity Inrush surge current < 30 A Power failure bypass > 40 ms (120 V AC) > 180 ms (230 V AC) Choice of suitable fuses 6 A ... 16 A (Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 5 V DC ±1 % Setting range of the output voltage 4.5 V DC ... 6 V DC (> 5 V DC constant capacity) Output current 10 A (-25°C ... 55°C) Derating 55 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series Yes Max. capacitive load Unlimited Current limitation Approx. 12 A (in the event of a short-circuit) Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 60 mVPP Peak switching voltages nominal load < 70 mVPP Maximum power dissipation NO-Load 1.5 W Power loss nominal load max. 13.5 W General Net weight 0.6 kg Efficiency > 80 % (230 V AC) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Protection class I MTBF (IEC 61709, SN 29500) > 500000 h
https://www.phoenixcontact.com/us/products/2902646 10/23/2014 Page 3 / 5 Power supply unit - TRIO-PS/ 1AC/ 5DC/10 - 2902646 Technical data General Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: Horizontally 0 mm, vertically 50 mm Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Low Voltage Directive Conformance with LV directive 2006/95/EC Standard – Electrical equipment of machines EN 60204 Standard - Safety of transformers EN 61558-2-17 Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) EN 61558-2-17 Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage EN 60950-1 (SELV) EN 60204 (PELV) Standard - Safe isolation DIN VDE 0100-410 Standard – Protection against electric shock DIN 57100-410 Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment DIN VDE 0106-101 Standard – Limitation of mains harmonic currents EN 61000-3-2 UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 Surge voltage category III Connection data, input Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 14 Stripping length 9 mm Screw thread M2,5 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24
https://www.phoenixcontact.com/us/products/2902646 10/23/2014 Page 4 / 5 Power supply unit - TRIO-PS/ 1AC/ 5DC/10 - 2902646 Technical data Connection data, output Conductor cross section AWG/kcmil max 14 Stripping length 9 mm Signaling Status display "DC OK" LED green Note on status display UOUT < 0.9 x UN: LED flashing Classifications eCl@ss eCl@ss 4.0 27040702 eCl@ss 4.1 27040702 eCl@ss 5.0 27242213 eCl@ss 5.1 27049002 eCl@ss 6.0 27049002 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 ETIM ETIM 3.0 EC001039 ETIM 4.0 EC002540 ETIM 5.0 EC002540 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 Drawings Block diagram L N
https://www.phoenixcontact.com/us/products/2902646 10/23/2014 Page 5 / 5 Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com