https://www.phoenixcontact.com/pi/products/2900320 03/19/2019 Page 1 / 5 Relay Module - PLC-RPT-110UC/21/RW - 2900320 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PLC-INTERFACE for railway applications, consisting of basic terminal block with push-in connection and plug- in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 1 PDT, input voltage 110 V DC Your advantages Optimum relay operation thanks to wide-range electronics Safe isolation according to DIN EN 50178 between coil and contact Vibration and shock resistance according to EN 50155 Certified according to EN 50155 Spring-cage and Push-in connection technology Temperature range from -40°C to +70°C (+85°C briefly) Input voltage range of 0.7 to 1.25 x UN (1.4 x UN briefly) Key Commercial Data Packing unit 10 pc GTIN GTIN 4046356510035 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 80 mm Depth 94 mm Ambient conditions Ambient temperature (operation) -40 °C ... 70 °C (Temperature class TX) Ambient temperature (storage/transport) -40 °C ... 85 °C
https://www.phoenixcontact.com/pi/products/2900320 03/19/2019 Page 2 / 5 Relay Module - PLC-RPT-110UC/21/RW - 2900320 Technical data Coil side Nominal input voltage UN 110 V DC Typical input current at UN 2 mA Typical response time 4 ms Typical release time 4 ms Coil voltage 60 V DC Protective circuit Bridge rectifier Bridge rectifier Free-wheeling diode Damping diode Surge protection RCZ filter Wide-range electronics Operating voltage display Yellow LED Power dissipation for nominal condition 0.22 W Contact side Contact type 1 PDT Type of switch contact Single contact Contact material AgSnO Maximum switching voltage
250 V AC/DC (Separating plate PLC-ATP must be installed for voltages
larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.) Minimum switching voltage 5 V (at 100 mA) Min. switching current 10 mA (at 12 V) Maximum inrush current 10 A (4 s) Limiting continuous current 6 A (see derating curve) Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity 1 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)
Connection data input side Connection name Coil side Connection method Push-in connection Stripping length 8 mm
https://www.phoenixcontact.com/pi/products/2900320 03/19/2019 Page 3 / 5 Relay Module - PLC-RPT-110UC/21/RW - 2900320 Technical data Connection data input side Conductor cross section AWG 26 ... 14 Connection data output side Connection name Contact side Connection method Push-in connection Stripping length 8 mm Conductor cross section AWG 26 ... 14 General Test voltage relay winding/relay contact 4 kVrms (50 Hz, 1 min.) Operating mode 100% operating factor Degree of protection RT III (Relay) IP20 (Relay base) Mechanical service life approx. 2x 10 cycles Mounting position any Assembly instructions In rows with zero spacing Net weight (SAP) 33.8 g Standards and Regulations Connection in acc. with standard CUL Standards/regulations EN 50155 (VDE 0115 part 200) EN 50178 EN 61373 EN 50121 Rated insulation voltage 250 V AC Rated surge voltage 6 kV Degree of pollution 2 Overvoltage category III Flammability rating according to UL 94 V0 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
https://www.phoenixcontact.com/pi/products/2900320 03/19/2019 Page 4 / 5 Relay Module - PLC-RPT-110UC/21/RW - 2900320 Drawings Diagram Cycles Switching□current□[A] 250□V AC,□ohmic□load 0 2 4 6 8 Electrical service life Diagram 0,1 0,2 0,3 0,5 10 20 30 50 70 100 300 200 ohmic□load Switching□voltage□[V] Switching□current□[A] DC interrupting rating Diagram 7060 65555045403530 Ambient□temperature□[°C] Current□carrying capacity□[A] Derating diagram Circuit diagram A2 11 Approvals Approvals Approvals DNV GL / UL Listed / UL Recognized / cUL Recognized / cUL Listed / EAC / RC FRT / cULus Recognized / cULus Listed Ex Approvals Approval details DNV GL http://exchange.dnv.com/tari/ TAE0000196-01
https://www.phoenixcontact.com/pi/products/2900320 03/19/2019 Page 5 / 5 Relay Module - PLC-RPT-110UC/21/RW - 2900320 Approvals UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140 EAC RU C- DE.A*30.B.01082 RC FRT B.00094 cULus Recognized cULus Listed Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8