2806_en_C AUTOMATION FL SWITCH SFN(T)… Data Sheet © PHOENIX CONTACT 2011-06-28 1D e s c r i p t i o n The FL SWITCH SFN(T)…16(15 )(14)TX… range of Factory Line switches can be used for quick and cost-effective Ethernet network expansion to the field level. These unmanaged switches provide simple, robust networking in an industrial environment. Due to the narrow housing design, the switches are suitable for use in control cabinets and junction boxes. The FL SWITCH SFNT… switch es allow operation across a wider temperature range than most switches, allowing networks to expand into process industry environments, such as oil/gas, chemical, water/wastewater, wind energy, security, and monitoring. The FL SWITCH SFN(T)…16(15)(14)TX… switches support the auto negotiation function on the RJ45 ports and offer transmission speeds of 10/100 Mbps. Mixed operation for the connection of segments with different data transmission speeds is also supported. The RJ45 ports offer an autocrossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. Fiber optic ports are available in an SC format and offer speeds of 100 Mbps. The fiber optic ports extend the segment length to 2000 m or more, depending on the quality of the fiber optic cable.
2 Features and Benefits
– -40 to 75°C operating range for SFNT switches – 0 to 60°C operating range for SFN switches – Auto-negotiation and autocross simplify cabling – Couple copper network segments with different bit rates with automatic detection of the data transmission speed of 10 or 100 Mbps – Individual LEDs at each po rt indicate communication activity and data rate – Redundant power supply capable with local (LED) and remote (dry contact) alarms to indicate failure of one or both power supplies – Available fiber optic options for extended distance and electrical noise immunity – Fiber optic ports available in SC formats This data sheet is valid for all products listed on the following page: Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments
FL SWITCH SFN(T)… 2806_en_C PHOENIX CONTACT 2 3O r d e r i n g D a t a Description Type Order No. Pcs./Pkt. Ethernet switch, with 16 RJ45 ports for 10/100 Mbps FL SWITCH SFN 16TX 2891933 1 Ethernet switch, with 15 RJ45 ports, 1 fiber optic port in SC format for 10/100 Mbps FL SWITCH SFN 15TX/FX 2891934 1 Ethernet switch, with 14 RJ45 ports, 2 fiber optic ports in SC format for 10/100 Mbps FL SWITCH SFN 14TX/2FX 2891935 1 Ethernet switch, wide temperature, with 16 RJ45 ports for 10/100 Mbps FL SWITCH SFNT 16TX 2891952 1 Ethernet switch, wide temperature, with 15 RJ45 ports, 1 fiber optic port in SC format for 10/100 Mbps FL SWITCH SFNT 15TX/FX 2891953 1 Ethernet switch, wide temperature, with 14 RJ45 ports, 2 fiber optic ports in SC format for 10/100 Mbps FL SWITCH SFNT 14TX/2FX 2891954 1 Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Security element for FL CAT patch FL PATCH SAFE CLIP 2891246 20 Color marker for FL PATCH GUARD, black FL PATCH GUARD CCODE BK 2891136 12 Color marker for FL PATCH GUARD, blue FL PATCH GUARD CCODE BU 2891233 12 Color marker for FL PATCH GUARD, orange FL PATCH GUARD CCODE OG 2891330 12 Color marker for FL PATCH GUARD, yellow FL PATCH GUARD CCODE YE 2891437 12 Color marker for FL PATCH GUARD, turquoise FL PATCH GUARD CCODE TQ 2891534 12 Color marker for FL PATCH GUARD, green FL PATCH GUARD CCODE GN 2891631 12 Color marker for FL PATCH GUARD, red FL PATCH GUARD CCODE RD 2891738 12 Color marker for FL PATCH GUARD, violet FL PATCH GUARD CCODE VT 2891835 12 Security element for FL PATCH FL PATCH GUARD 2891424 20 FL PATCH GUARD, key FL PATCH GUARD KEY 2891521 1 Dust protection cap FL RJ45 PROTECT CAP 2832991 10
FL SWITCH SFN(T)… 2806_en_C PHOENIX CONTACT 3
4 Technical Data
Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 µs plus frame time Housing dimensions (width x height x depth) 70 x 135 x 110 mm Weight, without connectors 870 g Operating temperature FL SWITCH SFN… FL SWITCH SFNT… 0°C to 60°C -40°C to 75°C Storage temperature -40°C to 85°C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) FL SWITCH SFN… FL SWITCH SFNT… 86 kPa to 108 kPa, 1500 m above sea level 62 kPa to 108 kPa, 4160 m above sea level Air pressure (storage) FL SWITCH SFN… FL SWITCH SFNT… 66 kPa to 108 kPa, 3500 m above sea level 62 kPa to 108 kPa, 4160 m above sea level Mounting NS35 (EN 60715) Preferred mounting position Perpendi cular to a standard mounting rail Connection to protective earth ground Snapped onto a grounded mounting rail Supply Voltage (US) Connection type Removable, screw-clamp connector Wire size (solid/stranded/AWG) 0.2 to 2.5 mm2 / 0.2 to 2.5 mm2 / 30 - 12 AWG Torque 0.6 - 0.8 Nm (5 - 7 lb f-in.) Recommended PE wire size 2.5 mm2 Nominal power supply 24 V DC Permissible ripple 3.6 Vpp within the permissible voltage range Permissible voltage range 12 V DC to 48 V DC Test voltage 500 V DC for one minute Protection against polarity reversal Present Current Consumption and Inrush Current Current Consumption (max) Inrush Current FL SWITCH SFN(T) 16TX 550 mA @ 12 V DC 275 mA @ 24 V DC 9.85 A @ 30 µs FL SWITCH SFN(T) 15TX/FX 630 mA @ 12 V DC 315 mA @ 24 V DC 9.7 A @ 30 µs FL SWITCH SFN(T) 14TX/2FX 715 mA @ 12 V DC 350 mA @ 24 V DC 10.0 A @ 30 µs Interfaces Total number of RJ45 Ethernet interfaces 14/15/16 MAC Address Table Size (Entries) 4 K Properties of RJ45 Ports Connection format 8-pos. RJ45 female connector on the switch Connection medium Twisted-pair cable wi th a conductor cross section of 0.14 mm2 to 0.22 mm2 Cable impedance 100 Ω Transmission speed 10/100 Mbps Maximum network segment length 100 m Properties of Fiber Optic Ports Connection format SC duplex female connector Fiber type Multimode Laser protection Class 1 according to DIN EN 60825-1:2001-11
FL SWITCH SFN(T)… 2806_en_C PHOENIX CONTACT 4 Transmission rate 100 Mbps full duplex Wavelength 1300/1310 nm Fiber optic segment length 12.1 km glass fiber with F-G 62.5/125 0.7 dB/km F1000 3.3 km glass fiber with F-G 62.5/125 2.6 dB/km F600 7.1 km glass fiber with F-G 50/125 0.7 dB/km F1200 3.1 km glass fiber with F-G 50/125 1.6 dB/km F800 Transmission power (medium type) dynamic (average) Minimum Maximum -23.5 dBm (50/125 µm) / -20 dBm (62.5/125 µm) -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Transmission power (medium type) static Minimum Maximum -22.5 dBm (50/125 µm) / -19 dBm (62.5/125 µm) -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Receiver sensitivity Minimum Maximum -31 dBm (dynamic) / -31 dBm (static) -14 dBm (dynamic) / -14 dBm (static) Alarm Contacts Voltage 24 V DC Current carrying capacity 1 A maximum including inrush Interfaces (Continued) Mechanical Tests Shock test according to IEC 60068-2-27 Operatio n: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1 m Conformance With EMC Directives Developed according to IEC 61000-6-2 IEC 61000-4-2 (ESD) Contact: ±4 kV, Criterion B Air: ±8 kV, Criterion B IEC 61000-4-3 (radiated-noise immunity) 10 V/m, Criterion A IEC 61000-4-4 (burst) Ports: ±1 kV, Criterion B DC power: ±2 kV, Criterion B IEC 61000-4-5 (surge) Ports: ±1 kV, Criterion B DC power: ±500 V, Criterion B IEC 61000-4-6 (conducted noise immunity) 10 Vrms, Criterion A IEC 61000-4-8 (noise immunity against magnetic fields) 30 A/m, Criterion A EN 55022 (noise emission) Class A Approvals General c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC Hazardous location U Class I, Zone 2 AEx nC IIC T4, EX nC nL IIC T4 X U Class I, Division 2 Groups A, B, C, D, T4
FL SWITCH SFN(T)… 2806_en_C PHOENIX CONTACT 5 5O v e r v i e w Figure 1 Connectors and LEDs (…15TX/FX shown)
5.1 Diagnostic and Status Indicators
6 Requirements for Operation in
The device must be installed within an enclosure rated at least IP54. Do not open the enclosure unless power has been switched off or the area is known to be non-hazardous. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.
7 Installation
Install the FL SWITCH SFN(T)… on a clean NS 35 rail. To avoid contact resistance, use only clean, corrosion-free rails that meet the EN 60715 standard. End clamps can be mounted on both sides of the module to stop the modules from slipping on the rail.
7.1 Assembly
- Place the module onto the rail from above. The upper holding keyway must be hooked onto the top edge of the rail. 2. Push the module from the front towards the mounting surface. 3. Once the module has been snapped on properly, check that it is fixed securely on the rail. Des. Color Status Meaning US1 and US2 green ON Supply voltage (US) in the tolerance range OFF Supply voltage (US) too low Link/ACT green ON Valid network connection Flashing Transmitting or receiving data At high data rates the Link/ACT LED blinking may appear to be a constant rate. FL SWITCH SFNT 15TX/FX Ord.No. 2891953 Link/ACTX8X1 X9X2 X10X3 X11X4 X12X5 X13X6 X14 X15 X16 X8X1 X9X2 X10X3 X11X4 X12X5 X13X6 X14 X15 X16X7 US2US1 Alarm connector Link/ACT LEDs Power LEDs (US1 and US2) Power connector WARNING: These instructions must be followed for proper use in hazardous locations. CAUTION: Only qualified personnel may start up and operate this device. Qualified personnel are persons authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. NOTE: The FL SWITCH SFN(T)… module is designed for SELV and PELV operation according to IEC 61140/EN 61140. NOTE: Connect the mounting rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the rail. Connect protective earth ground with low impedance.
FL SWITCH SFN(T)… 2806_en_C PHOENIX CONTACT 6
7.2 Removal
- Insert a suitable tool (e.g ., needle-nose pliers) into the arresting latch and pull it down. 2. Pull the module slightly away from the mounting surface. 3. Lift the module from the rail.
7.3 Power Connection
The switch is designed for SELV and PELV operation at +24 V DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. The FL SWITCH SFN(T)…16(15)(14)TX… switches provide the ability to connect redundant power supplies (see Figure 2). If redundant power supply is not required, a single power supply can be used (see Figure 3). Snapping the switch onto a grounded rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased by an additional low- impedance connection to protective earth (see Figure 2 and Figure 3). Figure 2 Power connections for redundant power supply Figure 3 Power connections for single power supply
7.4 Alarm Contact
The FL SWITCH SFN(T)…16(15)(14)TX… switch provides contacts (R1, R2) for remote monitoring if a power failure is detected. Alarms are triggered if one or both power supplies fail. The alarm relay is a normally closed type. When there are no faults, the contact is held open. When a fault occurs, the relay is de-energized to close the contact. Figure 4 Remote monitoring connection – +– + GND US1US2 X18 X17 GND GND US1US2 X18 X17 GND GND US1US2 X18 X GND
FL SWITCH SFN(T)… 2806_en_C 7PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O. Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com
7.5 Ethernet Interface
The FL SWITCH SFN(T)… has 14, 15, or 16 Ethernet ports on the front in RJ45 format to which only twisted-pair cables with an impedance of 100 Ω can be connected. The data transmission speed is 10/100 Mbps. In addition, every port has an autocrossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. Figure 5 RJ45 pin assignment
8 Switching Characteristics
All data telegrams received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. 9D i m e n s i o n s RJ45 n.c. n.c. TD- n.c. n.c. TD+ RD- RD+ 876 5 4 3 21 A restart deletes the entire address table. FL SWITCH SFNT 15TX/FX Ord.No. 2891953 Link/ACTX8X1 X9X2 X10X3 X11X4 X12X5 X13X6 X14 X15 X16 X8X1 X9X2 X10X3 X11X4 X12X5 X13X6 X14 X15 X16X7 US2US1 70 mm 10 mm Depth = 110 mm 135 mm