https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 1 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 2-channel operation, automatic or manual, monitored start, cross-circuit detection, 2 enabling current paths, US = 24 V DC, plug-in screw terminal block Why buy this product Up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061 Low housing width of just 12.5 mm Two-channel control 2 enabling current paths, 1 digital signal output Manually monitored and automatic activation in a single device Cross-circuit detection Key Commercial Data Packing unit 1 STK Weight per Piece (excluding packing) 160.000 g Custom tariff number 85371099 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 12.5 mm Height 112.2 mm Depth 114.5 mm
https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 2 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Technical data Ambient conditions Ambient temperature (operation) -40 °C ... 55 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing) Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing) Shock 15g Vibration (operation) 10 Hz ...150 Hz, 2g Maximum altitude ≤ 2000 m (Above sea level) Input data Rated control circuit supply voltage US 24 V DC -15 % / +10 % Power consumption at US typ. 1.56 W Rated control supply current IS typ. 65 mA Inrush current 4 A (Δt = 200 µs at Us) Current consumption < 5 mA (with Us/Ix to S12) < 5 mA (with Us/Ix to S22) > -5 mA (with Us/Ix to S34) > -5 mA (with Us/Ix to S22/S21) < 10 mA (with Us/Ix to S34) Voltage at input/start and feedback circuit 24 V DC -15 % / +10 % Typical response time < 175 ms (automatic start) < 175 ms (manual, monitored start) Typ. starting time with Us < 250 ms (when controlled via A1) Typical release time < 20 ms (when controlled via A1 or S12 and S22.) Recovery time < 500 ms Status display 3 x green LED Maximum switching frequency 0.5 Hz Max. permissible overall conductor resistance 150 Ω Filter time 1 ms (at A1 in the event of voltage dips at Us) max. 1.5 ms (at S12, S22; test pulse width) min. 7.5 ms (at S12, S22; test pulse rate) Test pulse rate = 5 x Test pulse width Output data Contact type 2 enabling current paths Contact material AgSnO2 Minimum switching voltage 12 V AC/DC Maximum switching voltage 250 V AC/DC (Observe the load curve) Limiting continuous current 6 A (observe derating)
https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 3 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Technical data Output data Inrush current, minimum 3 mA Maximum inrush current 6 A Sq. Total current 72 A (observe derating) Switching capacity min. 60 mW Output fuse 6 A gL/gG (N/O contact)
4 A gL/gG (for low-demand applications)
Number of outputs 1 (digital, PNP) Voltage 22 V DC (Us - 2 V) Current max. 100 mA Maximum inrush current 500 mA (Δt = 1 ms at Us) Short-circuit protection no General Relay type Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) Mechanical service life 10 x 10 cycles Nominal operating mode 100% operating factor Net weight 163.1 g Mounting type DIN rail mounting Assembly instructions See derating curve Mounting position vertical or horizontal Degree of protection IP20 Min. degree of protection of inst. location IP54 Control Two-channel Housing material PBT Housing color yellow Connection data Connection method Screw connection pluggable Yes Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 7 mm
https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 4 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Technical data Connection data Screw thread M3 Safety-related characteristic data Stop category 0 Designation IEC 61508 - High demand Safety Integrity Level (SIL) 3 Designation IEC 61508 - Low demand Safety Integrity Level (SIL) 3 Designation EN ISO 13849 Performance level (PL) e (4 A DC13; 5 A AC15; 8760 switching cycles/year) Category 4 Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) 3 Standards and Regulations Shock 15g Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 50178 Rated insulation voltage 250 V AC Rated surge voltage/insulation Safe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) Basic insulation 4 kV between all current paths and housing Degree of pollution 2 Overvoltage category III Vibration (operation) 10 Hz ...150 Hz, 2g Conformance CE-compliant Drawings
https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 5 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Block diagram A1 S22 S21 S34 A2 M1 13 23 14 24 S12S11 PWR 24V DC PSR-MC30 IN 1/2 K1 K2 Block diagram K1 K2 K3 K4 6 7 8 A1 S11 S22 S34 23 13 A2 S21 S12 2414M1 PSR-MC30 Key: 1 = Current limitation 2 = Input circuit 3 = Voltage limitation 4 = Start circuit 5 = Control circuit channel 1 6 = Control circuit signal output 7 = Control circuit channel 2 8 = Start channel 1 and 2 9 = Channel 1 10 = Diagnostics K1, K2 ... K4 = Force-guided elementary relays Circuit diagram M 24V DC N L PSR-MC30 S12S34 S22 ( )( ) S21( ) (GND) ( ) S11 (+) ( ) Classifications eCl@ss eCl@ss 5.1 27371901 eCl@ss 6.0 27371819 eCl@ss 8.0 27371819 eCl@ss 9.0 27371819
https://www.phoenixcontact.com/us/products/2700498 08/30/2016 Page 6 / 6 Safety relays - PSR-MC30-2NO-1DO-24DC-SC - 2700498 Classifications ETIM ETIM 5.0 EC001449 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / Functional Safety / GL / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324 EAC 7500651.22.01.00244 Functional Safety 44-205-13755201 GL http://www.gl-group.com/newbuilding/approvals/index.html 11253-14 HH cULus Listed Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com