25ACBE GAPTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 5 25ACBE_4 – Rev. 2020-1.1 Specifications subject to change without notice. Certification Model Output power [W] Output [V] Output [mA] Efficiency [%, typ] Capacitive load [µF, max] UL/CE/CB 25ACBE_03S4 13.53 3.3 4100 74 48000 UL/CE/CB 25ACBE_05S4 20.5 5 4100 79 12240 UL/CE/CB 25ACBE_09S4 25 9 2500 81 5600 UL/CE/CB 25ACBE_12S4 25 12 2100 83 5400 UL/CE/CB 25ACBE_15S4 25 15 1600 84 2400 UL/CE/CB 25ACBE_24S4 25 24 1100 85 1440 UL/CE/CB 25ACBE_48S4 25 48 500 87 600 25ACBE_4 series 25W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Universal input: 85-264VAC/100-370VDC Operating temperature range: -40°C to +85°C High Isolation 4000VAC Short circuit protection (SCP) High efficiency, high reliability Low ripple and noise Output over voltage, over current protection Meet EMI CISPR32/EN55032 CLASS B IEC62368, UL62368, EN62368 approved AC-DC Converter 25 Watt The 25ACBE_4 series are compact size power converters. They feature universal input voltage, taking both DC and AC input voltage, low pow - er consumption, high efficiency, high reliability, safer isolation. The con - verters offer good EMC performance and meet IEC/EN61000-4, CISPR32/ EN55032, UL62368 and EN62368 standards. They are widely used in industrial, electricity, instrumentation, telecom - munications and civil applications. For extremely harsh EMC environ - ment, we strongly recommend using the application circuit of this da - tasheet. Output specifications Voltage set accuracy • 3.3V: ±3% (typ)

  • others: ±2% (typ) Line regulation (Rated load) ±0.5% (typ) Load regulation (0% to 100%) ±1% Ripple & Noise* 50mV typ., 100mV max. Short circuit protection Hiccup mode, indefinite (automatic recovery) Over current protection ≥140%Io, self-recovery Over voltage protection • 3.3V/5V: 7.5V
  • 9V: 15V
  • 12V/15V: 20V
  • 24V: 30V
  • 48V: 60V Hold-up time • 115VAC: 10ms (typ)
  • 230VAC: 60ms (typ) * The “parallel cable” method is used for ripple and noise test. Input specifications Input voltage range 85-264VAC, 100-370VDC Input frequency 47-63Hz Input current (full load) 115VAC
  • 0.6A (typ) 230VAC
  • 0.34A (typ) Inrush current (<2ms, cold start) 115VAC
  • 20A (typ) 230VAC
  • 40A (typ) Hot plug Unavailable Example: 25ACBE_05S4 25 = 25Watt; AC = AC-DC; B = case style; E = Cost effective; 25Vout; S = Single Output; 4 = 4kVAC isolation Note: 1. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta = 25°C, humidity <75% with nominal input voltage and rated output load; 2. All index testing methods in this datasheet are based on our company corporate standards; 3. We can provide product customization service, please contact our technicians directly for specific information; 4. Products are related to laws and regulations: see „Features“ and „EMC“; 5. Our products shall be classified according to ISO14001 and related environmen- tal laws and regulations, and shall be handled by qualified units. UL-62368-1 (E347551)

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 5 25ACBE_4 – Rev. 2020-1.1 Specifications subject to change without notice. 25ACBE_4 series 25W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Common specifications Operating temperature range -40°C ~ +85°C Storage temperature range -40°C ~ +85°C Power derating • -40°C ~ -10°C: 2.00 %/°C (min)

  • 85VAC-100VAC: 1.00 %/VAC (min)
  • 240VAC-264VAC: 0.83 %/VAC (min) Humidity 95% MAX Temperature coefficient 0.02%/°C Soldering temperature Wave-soldering: 260 ± 5°C; time: 5 - 10s Manual-welding: 360 ± 10°C; time: 3 - 5s I/O-isolation voltage 4000VAC/1Min EMC / EMI / CE CISPR32/EN55032 CLASS B EMC / EMI / RE CISPR32/EN55032 CLASS B EMC / EMS / ESD IEC/EN 61000-4-2 Contact ±6KV / Air ±8KV perf. Criteria B EMC / EMS / RS IEC/EN 61000-4-3 10V/m perf. Criteria A EMC / EMS / EFT • IEC/EN 61000-4-4 ± 2kV perf. Criteria B
  • IEC/EN 61000-4-4 ± 4kV (see EMC recommended circuit) perf. Criteria B EMC / EMS / Surge • IEC/EN 61000-4-5 line to line ±1KV/ line to ground ±2KV perf. Criteria B
  • IEC/EN 61000-4-5 line to line ±2KV/ line to ground ±4KV perf. Criteria B (see EMC recommended circuit) EMC / EMS / CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A EMC / EMS / Voltage dips, short and interruptions immunity IEC/EN61000-4-11 0%-70% perf. Criteria B Safety standards IEC62368/EN62368/UL62368 Safety class CLASS I Case material UL94V-0 Install PCB mounting MTBF (MIL-HDBK-217F@25°C) >300,000h Cooling Free air convection Package 70.00 x 48.00 x 23.50mm 96.10 x 54.00 x 32.00mm (Chassis mounting) 96.10 x 54.00 x 36.60mm (Dinrail mounting) Weight 120g 170g (Chassis mounting) 210g (Dinrail mounting) Typical characteristics Note: ①When input 85-100VAC/240-264VAC/100-120VDC/340-370VDC, it need to be voltage derated on basis of temperature derating; ②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company.

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 3 of 5 25ACBE_4 – Rev. 2020-1.1 Specifications subject to change without notice. 25ACBE_4 series 25W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Efficiency Typical application circuit EMC solution recommended circuit Model C1 (µF) C2 (µF) Fuse MOV TVS 25ACBE_03S4 1 330 3.15A/250V slow-blow, required S14K300 SMBJ7.0A 25ACBE_05S4 1 330 3.15A/250V slow-blow, required S14K300 SMBJ7.0A 25ACBE_09S4 1 330 3.15A/250V slow-blow, required S14K300 SMBJ12A 25ACBE_12S4 1 330 3.15A/250V slow-blow, required S14K300 SMBJ20A 25ACBE_15S4 1 330 3.15A/250V slow-blow, required S14K300 SMBJ20A 25ACBE_24S4 1 120 3.15A/250V slow-blow, required S14K300 SMBJ30A 25ACBE_48S4 1 68 3.15A/250V slow-blow, required S14K300 SMBJ64A Component Recommended value MOV S14K300 CY1, CY2 1000pF/400VAC CX 0.1μF/275VAC LCM 10mH L1 4.7μH/2A FC-LX1D 2KV/4KV EMC filter FUSE 3.15A/250V slow-blow, required 25ACBE_24S4 25ACBE_12S4 25ACBE_05S4 25ACBE_24S4 25ACBE_12S4 25ACBE_05S4 Note: Output filtering capacitors C2 is electrolytic capacitors, it is recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and cur- rent of capacitor please refer to manufacture’s datasheet. Capacitor voltage redu- ced to at least 80%. C1 is ceramic capacitors, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails. EMC recommended circuit with higher requirements

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 4 of 5 25ACBE_4 – Rev. 2020-1.1 Specifications subject to change without notice. 25ACBE_4 series 25W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Trim Mechanical dimensions Trim Function for Output Voltage Adjustment (open if unused)

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 5 of 5 25ACBE_4 – Rev. 2020-1.1 Specifications subject to change without notice. 25ACBE_4 series 25W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Chassis mounting Din Rail mounting