Features
n Second Source Compatible to the BUS-65610 n 16MHz CT2565 Replacement n RTU implements all dual redundant mode codes n Selective mode code illegalization available n 16 bit microprocessor compatibility n BC checks status word for correct address and set flags n RTU illegal mode codes externally selectable n 16 bit µProcessor compatibility n DMA handshaking for subsystem message transfers n Continuous On-Line and Initiated Built-In-Test n MIL-PRF-38534 compliant circuits available n Packaging – Hermetic Metal
- 78 Pin, 2.1" x 1.87" x .25" Plug-In type package
- 82 Lead, 2.2" x 1.61" x .18" Flat package General Description The CT2561 is a 16 MHz single chip dual redundant MIL-STD-1553 Bus Controller (BC), Remote Terminal Unit (RTU) and Bus Monitor (MT). Packaged in a hybrid plug-in or flatpack, the CT2561 performs all the functions required to interface a MIL-STD-1553 dual redundant serial data bus such as ACT4487 and a subsystem parallel three-state data bus. Using a single Aeroflex custom monolithic ASIC design, the CT2561 features pin-for-pin and functional CT2565 compatibility, user initiated self-test, and low power consumption. Compatible with most microprocessors the CT2561 provides a 16bit three-state parallel data bus and uses direct memory access (DMA type) handshaking for subsystem transfers. All message transfer timing, DMA and control lines are provided internally, thereby reducing the subsystem overhead associated with message transfers. The CT2561 implements all dual redundant MIL-STD-1553 mode codes. In addition, any mode code may (Optionally) be legalized through the use of an external PROM. Complete error detection is provided by the CT2561 for BC and RTU operation. Error detection includes: response time-out, inter-message gaps, sync, parity, Manchester, word count and bit count. The CT2561 is fully compliant with MIL-STD-1553, is available screened in accordance with the requirements of MIL-STD-883 and operates over the full military temperature range of -55°C to +125°C. CT2561 FOR MIL-STD-1553B FI EI DCE R T A E ROFLEX L ABS INC .ISO9001 CIRCUIT TECHNOLOGY www.aeroflex.com
Aeroflex Circuit Technology 2 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 BUSGRNT BUSREQ SOM BUSACK INCMD EOM OE CS WR CHA/CHB BCSTART MSGERR LOOPERR LWORD STATERR STATEN HSFAIL NBGRNT BITEN NODT ADRINC BSCTRCV TIMEOUT I/O LOGIC BUFFERS BUFENA I/O0 - I/O16 LMC WC0-WC4 ILLCMD T/R SERREQ DBACCEPT SSBUSY SSERR SSFLAG DATA BUFFERS REMOTE TERMINAL LOGIC BUS CONTROLLER LOGIC DATA BUS STATUS INPUTS MODE CODE CONTROL CH B CONTROL CH A ENCODE/ DECODE CH B ENCODE/ DECODE TXDATA A TXINH A RXDATA A RXDATA A TXDATA A RTADDR PARITY CHECKER TXDATA B TXINH B RXDATA B RXDATA B TXDATA B RTADDR RTADDR RTADR2 RTADR0 RTADR4 RTADR3 RTADR1 RTADRP CONTROL BUS Figure 1 – CT2561 Block Diagram 16MHz MT RT/BC TESTOUT TESTIN CH A CONTROL I/O BUS ENR/W
Aeroflex Circuit Technology 3 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 Table 1A – Pin Function Table (78 Pin Plug-In) Pin # Symbol I/O Description 1 RT/BC I Mode Select input - logic "1" for RT mode, logic “0” for BC mode. 2 MT I Monitor mode enable. When unit is operating as a BC, a logic “0” will select monitor mode.
3 STATEN O Output signal in RT mode that indicates status word is being transferred on the
internal bus.
4 TIMEOUT O Indicates No Response Timeout has occurred during BC and RTU (RT to RT
transfer).
5 HSFAIL O Output in RT mode indicating the DMA transfer did not occur in time to allow
proper operation on the 1553 bus.
6 DBACCEPT I Input signal used to set DBACCEPT bit in status register for response to a valid
mode command on the 1553 bus. 7 SSFLAG I Input which controls the SSFLAG bit in the status register. 8 SVCREQ I Input which controls the service request bit in the status word. 9 INCMD O Output signal indicating the RT is currently in a message transfer sequence. 10 SSER I Input which controls the subsystem error bit in the status register. 11 TESTOUT - Factory test point. Do not connect. 12 WC1 O WC bit 1 - latched output of command word. 13 WC3 O WC bit 3 - latched output of command word. 14 TXINH B O Transmitter inhibit output for channel B. 15 T/R O Output indicating T/R bit of current command word in RT mode. 16 CHA/CHB O Output indicating current selected channel (0 = Channel A). 17 CS O Chip Select output for subsystem memory control. 18 OE O Output Enable output for subsystem memory control. 19 BUSREQ O Output signal used to initiate transfer to/from subsystem. 20 +5V I +5 Volt DC input. 21 DB0(LSB) I/O Least significant bit - 16 bit parallel data bus. 22 DB2 I/O Bit 2 of data bus. 23 DB4 I/O Bit 4 of data bus. 24 DB6 I/O Bit 6 of data bus. 25 DB8 I/O Bit 8 of data bus. 26 DB10 I/O Bit 10 of data bus. 27 DB12 I/O Bit 12 of data bus. 28 DB14 I/O Bit 14 of data bus.
Aeroflex Circuit Technology 4 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700
29 LWORD - Last word output during BC mode indicates last data word of the current
message transfer has been transferred on the parallel bus.
30 MSGERR O Output signal which indicates an error occurred during the current message
sequence. 31 TXDATA A O Bipolar serial data output to positive input of bus transceiver. 32 RXDATA A I Bipolar serial input from negative output of bus transceiver. 33 RTADP I Parity bit input for RT address. 34 RTAD1 I Bit 1 of RT address input. 35 RTAD3 I Bit 3 of RT address input. 36 RESET I System reset input - resets all inputs in module. 37 TXDATA B O Bipolar serial data output to negative input bus transceiver. 38 RXDATA B I Bipolar serial data input from positive output of bus transceiver. 39 16MHz I 16MHz TTL clock input. 40 GROUND - Signal ground. 41 BCSTART I Cycle enable input Logic "0" initiates bus controller message transfer operation.
42 NBGRNT O New bus grant output from RT indicates beginning of message transfer
sequence.
43 BITEN O Built in Test enable output indicates RT is transferring BlT word on internal 16 bit
bus. 44 WR O Write enable output for control of subsystem memory. 45 BUSGRNT I Bus request input in response to DTREQ. Allows BC/ RT to transfer data to subsystem. 46 LOOPERR O Loop error output. Logic "0" indicates failure of loop back transmitted data. 47 SSBUSY I Subsystem busy input for RT status word. 48 ILLCMD I Illegal command input to RT, used to block RT response to an illegal command. 49 ADRINC O Increment output pulse. Goes LOW at the completion of each word transfer to/from subsystem. Can increment external address counter.
50 CHASSIS - Frame ground electricity isolated from signal ground
51 WC0 O LSB of current command word count field. 52 WC2 O Bit 2 of word count field. 53 WC4 O Bit 4 of word count field. 54 TXINH A O Transmitter inhibit output signal for Channel A. 55 LMC O Latched Mode Command. Logic "1" indicates current word command is a mode code word, WC0-WC4. 56 TESTIN - Factory test point. Do not connect. Table 1A – Pin Function Table (78 Pin Plug-In) (continued) Pin # Symbol I/O Description
Aeroflex Circuit Technology 5 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 57 EOM O End of message output. Logic "0" occurs when BC/ RT message is completed.
58 BUFENA I Buffer enable input, may be driven LOW by STATEN or BITEN if subsystem
must read bit or Status words. Enables internal 16 bit bus onto subsystem bus. 59 BUSACK O Bus acknowledge output. LOW during DMA Handshake, in response to BUSGRNT. 60 DB1 I/O Bit 1 of 16 bit parallel bus. 61 DB3 I/O Bit 3 of 16 bit parallel bus. 62 DB5 I/O Bit 5 of 16 bit parallel bus. 63 DB7 I/O Bit 7 of 16 bit parallel bus. 64 DB9 I/O Bit 9 of 16 bit parallel bus. 65 DB11 I/O Bit 11 of 16 bit parallel bus. 66 DB13 I/O Bit 13 of 16 bit parallel bus. 67 DB15(MSB) I/O Bit 15 of 16 bit parallel bus.
68 STATERR O BC output indicates one or more bits set or address mismatch in a received
status word. 69 TXDATA A O Bipolar serial data output to negative input of bus transceiver. 70 RXDATA A I Bipolar serial data input from positive output of bus transceiver. 71 NODT O No data input. Logic "0" indicates the 1553 bus is idle; HIGH means device front end is active. 72 RTAD0 I LSB of 5 bit RT address. 73 RTAD2 I Bit 2 of RT address. 74 RTAD4 I Bit 4 of RT address. 75 BCSTRCV O Broadcast receive. Logic "0" means the current command was a broadcast command. 76 TXDATA B O Bipolar serial output to positive input of bus transceiver. 77 RXDATAB I Bipolar serial input from negative output of bus transceiver.
78 SOM O Start of message output indicates beginning of RT/ BC message transfer
sequence. Table 1A – Pin Function Table (78 Pin Plug-In) (continued) Pin # Symbol I/O Description
Aeroflex Circuit Technology 6 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 RT/BC BCSTART MT NBGRNT STATEN BITEN TIMEOUT WR HSFAIL BUSGRNT DBACCEPT LOOPERR SSFLAG SSBUSY SVCREQ ILLCMD INCMD ADRINC SSER CASE GND TESTOUT WC0 WC1 WC2 WC3 WC4 TXINH B TXINH A T/R LMC CHB/CHA TESTIN CS EOM OE BUFENA BUSREQ BUSACK +5 Volt DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 DB8 DB9 DB10 DB11 DB12 DB13 DB14 DB15 (MSB) LWORD STATERR MSGERR TXDATA A TXDATA A RXDATA A RXDATA A NODT RTADP RTAD0 RTAD1 RTAD2 RTAD3 RTAD4 RESET BCSTRCV TXDATA B TXDATA B RXDATA B RXDATA B 16MHz SOM GND CT2561 MIL-STD-1553 BUS Controller, Remote Terminal and Plug-In Pin Connection Diagram, CT2561 and Pinout Table 1B – CT2561 Pin Out Description (Plug-In) Pin # Function Pin # Function
1 RT/BC 40 GND
2 MT 41 BCSTART
3 STATEN 42 NBGRNT
4 TIMEOUT 43 BITEN
5 HSFAIL 44 WR
6 DBACCEPT 45 BUSGRNT
7 SSFLAG 46 LOOPERR
8 SVCREQ 47 SSBUSY
9 INCMD 48 ILLCMD
10 SSER 49 ADRINC
11 TESTOUT 50 CASE GND
12 WC1 51 WC0
13 WC3 52 WC2
14 TXINH B 53 WC4
15 T/R 54 TXINH A
16 CHB/CHA 55 LMC
17 CS 56 TESTIN
18 OE 57 EOM
19 BUSREQ 58 BUFENA
21 DB0 (LSB) 60 DB1
22 DB2 61 DB3
23 DB4 62 DB5
24 DB6 63 DB7
25 DB8 64 DB9
26 DB10 65 DB11
27 DB12 66 DB13
28 DB14 67 DB15 (MSB)
29 LWORD 68 STATERR
30 MSGERR 69 TXDATA A
31 TXDATA A 70 RXDATA A
32 RXDATA A 71 NODT
33 RTADP 72 RTAD0
34 RTAD1 73 RTAD2
35 RTAD3 74 RTAD4
36 RESET 75 BCSTRCV
37 TXDATA B 76 TXDATA B
38 RXDATA B 77 RXDATA B
Aeroflex Circuit Technology 7 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 RT/BC BCSTART MT NBGRNT STATEN BITEN TIMEOUT WR HSFAIL BUSGRNT DBACCEPT LOOPERR SSFLAG SSBUSY SVCREQ ILLCMD INCMD ADRINC SSER CASE GND TESTOUT WC0 WC1 WC2 WC3 WC4 TXINH B TXINH A T/R LMC CHB/CHA TESTIN CS EOM OE BUFENA BUSREQ BUSACK +5V DB0 (LSB) DB1 DB2 DB3 DB4 DB5 DB6 DB7 DB8 DB9 DB10 DB11 DB12 DB13 DB14 DB15 (MSB) LWORD STATERR MSGERR TXDATA A TXDATA A RXDATA A RXDATA A NODT RTADP RTAD0 RTAD1 RTAD2 RTAD3 RTAD4 RESET BCSTRCV TXDATA B TXDATA B RXDATA B RXDATA B 16MHz SOM GROUND Table 2 – CT2561 Pin Out Description (FP) Pin # Function Pin # Function
1 N/C 42 N/C
2 RT/BC 43 GROUND
3 BCSTART 44 SOM
4 MT 45 16MHz
5 NBGRNT 46 RXDATA B
6 STATEN 47 RXDATA B
7 BITEN 48 TXDATA B
8 TIMEOUT 49 TXDATA B
9 WR 50 BCSTRCV
10 HSFAIL 51 RESET
11 BUSGRNT 52 RTAD4
12 DBACCEPT 53 RTAD3
13 LOOPERR 54 RTAD2
14 SSFLAG 55 RTAD1
15 SSBUSY 56 RTAD0
16 SVCREQ 57 RTADP
17 ILLCMD 58 NODT
18 INCMD 59 RXDATA A
19 ADRINC 60 RXDATA A
20 SSER 61 TXDATA A
21 CASE GND 62 TXDATA A
22 TESTOUT 63 MSGERR
23 WC0 64 STATERR
24 WC1 65 LWORD
25 WC2 66 DB15 (MSB)
26 WC2 67 DB14
27 WC4 68 DB13
28 TXINH B 69 DB12
29 TXINH A 70 DB11
30 T/R 71 DB10
31 LMC 72 DB9
32 CHB/CHA 73 DB8
33 TESTIN 74 DB7
34 CS 75 DB6
35 EOM 76 DB5
36 OE 77 DB4
37 BUFENA 78 DB3
38 BUSREQ 79 DB2
39 BUSACK 80 DB1
40 +5V 81 DB0 (LSB)
41 N/C 82 N/C
Flat Package Pin Connection Diagram, CT2561 and Pinout N/C N/C N/C N/C CT2561FP MIL-STD-1553 BUS Controller, Remote Terminal and BUS MONITOR
Aeroflex Circuit Technology 8 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 .100 2.100 1.500 TYP Lead 1 & ESD Designator 1.900 1.800 Pin 19 Pin 20 Pin 59 Pin 41 Pin 2 .050 TYP 1.650 1.870 .100 .110Pin 1 .250 .250 MAX Pin 39 Pin 40 Pin 78 Pin 22 Pin 21 Pin 60 .018 DIA TYP .080 .180 MAX .010 ±.002.015 2.000 Pin 42 .095 Pin 41 2.200 MAX Lead 1 & ESD Designator 1.610 MAX Designator MAX .400 MIN .050 Lead Centers
41 Leads/Side
(4 Places) Pin 82 .050 Figure 2 – Plug In Package Outline Figure 3 – Flat Package Outline
Aeroflex Circuit Technology 9 SCDCT2561 REV A 8/16/99 Plainview NY (516) 694-6700 CIRCUIT TECHNOLOGY Aeroflex Circuit Technology
35 South Service Road
Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: (800) THE-1553 Specifications subject to change without notice www.aeroflex.com/act1.htm E-Mail: sales-act@aeroflex.com
Ordering Information
Model Number Screening Package CT2561 Military Temperature, -55°C to +125°C, Screened to the individual test methods of MIL-STD-883 Plug in CT2561-FP Flat Package