2250-XC6DT2 MTU | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
DIESEL ENGINE-GENERATOR SET 2250-XC6DT2 2250 ekW / 60 Hz / Standby 2100 ekW / 60 Hz / Prime 480 - 13.8kV A tognum grouP BrAnd SySTEm RATINGS Standby Voltage (L-L) 480V** 600V 4160V 12470V 13200V 13800V Phase 3 3 3 3 3 3 Hz 60 60 60 60 60 60 kW 2250 2250 2250 2250 2250 2250 AMPS 3383 2706 390 130 123 118 skVA@30% Voltage Dip 8400 3900 5000 C/F C/F C/F Generator Model* 744RSL4058 1020FDS1013 744FSM4376 1020FDH5584 1020FDH5584 1020FDH5584 Temp Rise 130°C/27°C 125°C/40°C 130°C/27°C 130°C/27°C 130°C/27°C 130°C/27°C Connection 4 BAR WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE Prime Voltage (L-L) 480V 600V 4160V 12470V 13200V 13800V Phase 3 3 3 3 3 3 Hz 60 60 60 60 60 60 kW 2100 2000 2100 2100 2100 2000 kVA 2625 2500 2625 2625 2625 2500 AMPS 3157 2406 364 121 115 110 skVA@30% Voltage Dip 8400 3900 5000 C/F C/F C/F Generator Model* 744RSL4058 1020FDS1013 744FSM4376 1020FDH5584 1020FDH5584 1020FDH5584 Temp Rise 105°C/40°C 105°C/40°C 105°C/40°C 105°C/40°C 105°C/40°C 105°C/40°C Connection 4 BAR WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered
// Engine Air Cleaners Oil Pump Full Flow Oil Filter Jacket Water Pump Inter Cooler Water Pump Thermostats Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electric Isochronous Base - Structural Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130°C Standby Temperature Rise
1 Bearing, Sealed
125% Rotor Balancing 3-Phase Voltage Sensing ±.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content // digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator
16 Programmable Contact Inputs
7 Contact Outputs
UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA1 10 Level Compatible STANDARD EQUIPmENT // EPA Tier 2 Certified // Engine-Generator Set Tested to ISO 8528-5 for Transient Response // UL2200, CSA Listing Offered // Accepts Rated Load in One Step Per NFPA 1 10, Level 1 // All engine-generator sets are prototype and factory tested // MTU Onsite Energy is a single source supplier // Global Product Support // 2 Year Standard Warranty // Custom Design for Any Application // 16V4000 G83 Diesel Engine - 76.3 Liter Displacement - Common Rail Injection - 4-Cycle // Complete Range of Accessories // Permanent Magnet Generator (PMG) - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings // Digital Control Panel(s) - UL Recognized, , NFPA 1 10 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan FACTS
// Engine Manufacturer MTU Detroit Diesel Model 16V4000 G83 (T1638A36) Type 4-Cycle Arrangement 16-V Displacement: Cu In (lit) 4,656 (76.3) Bore: in (cm) 6.69 (17) Stroke: in (cm) 8.27 (21) Compression Ratio 16.5:1 Rated RPM 1,800 Engine Governor ADEC Max Power: Standby: bhp (kWm) 3,351 (2,500) Max Power: Prime: bhp (kWm) 3,056 (2,280) Regulation ±.25% Frequency 60 Hz Air Cleaner Dry // Liquid Capacity (Lubrication) Total Oil System: gal (lit) 79.3 (300) Engine Jacket Water Capacity: gal (lit) 46.2 (175) After Cooler Water Capacity: gal (lit) 13.2 (50) System Coolant Capacity: gal (lit) 172 (651) // Electrical Electric Volts DC 24 Cold Cranking Amps Under 0°F (-17.8°C) 2,600 // Fuel System Fuel Supply Connection Size 1” NPT Fuel Return Connection Size 3/4” NPT Maximum Fuel Lift: ft (m) 3 (1) Recommended Fuel Diesel #2 Total Fuel Flow: gal/hr (lit/hr) 269 (1,020) // Fuel Consumption STANDBY PRIME At 100% of Power Rating: gal/hr (lit/hr) 163 (617) 147 (558) At 75% of Power Rating: gal/hr( lit/hr) 123 (467) 113 (426) At 50% of Power Rating: gal/hr (lit/hr) 86 (325) 79 (299) // Cooling - radiator System STANDBY PRIME Ambient Capacity of Radiator: °F (°C) 104 (40) 104 (40) Max. Restriction of Cooling Air, Intake, Water Pump Capacity: gpm (lit/min) 357 (1,350) 357 (1,350) After Cooler Pump Capacity: gpm (lit/min) 154 (583) 154 (583) Heat Rejection to Coolant: BTUM (kW) 54,993 (967) 49,704 (874) Heat Rejection to After Cooler: BTUM (kW) 42,539 (748) 38,160 (671) Heat Radiated to Ambient: BTUM (kW) 11,711 (206) 10,615 (186.7) // Air requirements STANDBY PRIME Aspirating: *SCFM (m3/min) 6,780 (192) 6,357 (180) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) 89,005 (2,520) 89,005 (2,520) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 26,412 (752) 23,940 (682) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) // Exhaust System STANDBY PRIME Gas Temp. (Stack): °F (°C) 941 (505) 896 (480) Gas Volume at Stack Temp: CFM (m3/min) 17,799 (504) 16,103 (456) Maximum Allowable APPLICATION DATA
© MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 // tognum group Companies: Europe / middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // uSA / Canada / mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for Hotmodule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com EmISSIONS DATA nox + nmHC Co Pm C/F C/F C/F All units are in g/hp-hr and are EPA d2 cycle values. Emission levels of the engine may vary as a function of ambi- ent temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under cont- rolled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaran- teed to be below the US EPA Standards at the US EPA defined conditions. RATING DEFINITIONS AND CONDITIONS // Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capa- bility for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. // Deration Factor: Altitude: 0.7% per 328 ft (100 m) above 3,1 17 ft (950 m) at 77°F (25°C). Max operation height 4,429 ft (1,350 m) for standby and 5,905 ft (1,800 m) for prime. temperature: 1% per 9°F (5°C) over 1 13°F (45°C) at 328 ft (100 m). WEIGhTS AND DIMENSIONS SOUND DATA unit type Standby Full Load Standby no Load Prime Full Load Prime no Load OPU w/Critical Grade Muffler (dBA) 104.5 97 103 97 System dimensions (L x W x H) Weight (less tank) OPU 260.88 x 90 x 117.88 in (6,630 x 2,290 x 2,990 mm) 37,466 lb (16,994 kg) Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. Materials and specifications subject to change without notice. Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. Measurements for sound data are taken at 23 ft (7 m).