204PRO4-433F RFSOLUTIONS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 1 PRO Professional Radio Control Series 204 205
- Ready to Use Remote Control
- 4, 8/16 Channel Systems
- Range: /head2right Up to 200 metres at 433MHz /head2right Up to 1,000 metres at 433MHz NB
- Relay Outputs: Momentary, Latching, Timed
- Receiver IP65
Applications
- Lighting Control
- General Purpose Remote Switching
- Door Control
- Industrial remote Switching
- Access Control Available as 4 - 16 channels the Professional range are ready to operate general purpose remote control systems using a highly secure transmission protocol for reliable operation. The receiver unit is rated IP65 with integral power supply containing industrial standard ‘DIN Rail’ ‘receiver’ and ‘relay output’ modules (interchangea ble). Other modules with higher switching capability are available. The relay outputs may be user set to operate as lat ching or momentary. Output 1 may be set to timed from 1-15 minutes. Additional transmitters can be added using the easy learn procedure. Any transmitter switch can be mapped to any individual or combination of receiver output(s).
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 2 PRO Professional Radio Control Series Part Number Description Range (Metres) Freq (MHz) Relay Outputs (each @230Vac) 204PRO4-433F 4 channel Remote Control System 100 43 3.92 4 x 12A 204PRO16-433F 16 channel Remote Control System 100 433.92 16 x 12A 205PRO4-433F 4 channel Remote Control System 200 43 3.92 4 x 12A 205PRO8-525N 8 channel Remote Control System 1,000 434.525 8 x 12A Range stated is optimum, direct line of sight. In worst conditions this can be reduced by up to 50% Custom systems We regularly supply pre-wired / bespoke systems, please contact our sales dept for further assistance Receiver Unit The receiver consists of interchangeable modules which are connected via ribbon cables. (as shown below) Antenna The Antenna is held internally, this is to save drilling the enclosure on the top. This may have some effect to the range for specific applications which may require the antenna externally mounted. At all times please ensure that antenna is pointing in a vertical direction and away from high interference sources. R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E. Sussex, BN8 6JL, England Tel +44 (0)1273 898 000 Fax +44 (0)1273 480 661 RF Solutions is a member of the Low Power Radio Association Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 3 PRO Professional Radio Control Series
11 Pre-Configuring the Remote Control System
There are three Steps: 1. Pre-Configure the 210Rx to operate with a type o f Transmitter (e.g. the 204 range or 205 range) 2. Map the Transmitter(s) switch(es) to the 210Rx o utput(s) 3. Set the 210Rx outputs to be latching, momentary or timed.
1.1 Pre-Configure the 210Rx to operate with a Trans mitter Series
- Ensure option link J8 is open. 2. Apply power to the 210Rx, All output LEDS flash alternately. This is factory reset default state. 3. Briefly Press any switch on the transmitter. The 210Rx will now confirm this by flashing LED 1 t o show it is configured for use with a handheld transmitter. Note This will now happen at each power on.
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 4 PRO Professional Radio Control Series Mapping a Transmitter Switch to a 210 Receiver Output One or many transmitter switches may be mapped to o ne or many 210Rx outputs, Decide which switch on th e Transmitter is to operate which output channel on the 210 Receiver decoder. 1. Briefly press the 210 Rx learn switch until the LED1-16 indicates the desired output channel 2. Operate the desired transmitter switch briefly 3. The LED on the 210Rx will extinguish. 4. Operate the desired transmitter switch briefly a gain 5. The LED on the 210Rx will turn on briefly and th en extinguish. 6. The selected transmitter switch will operate the 210Rx output channel. This procedure may be repeated for each transmitter and each 210Rx output required.
1.2 Configuration of the 210Rx Receiver Decoder Out puts
Option links LK 1-16 configure the operation of the outputs. Please note that the link status is read only on ‘power up’ and thus after changing the links, power must be removed and re-applied. LK 1–16 Output 1 Outputs 2 -16 Open Mom or Timed Mom (The O/P operates for as long as the transmitter switch is held on) Connected Latch or Timed Latch (The O/P changes state each time the Transmitter is operated)
1.2.1 Setting the Timed output (Channel 1)
This is set by VR1 with a delay of from 0 to 15 minutes. To set the time delay: 1. Remove power. 2. Place a shorting link header on option link J8. 3. Apply power 4. Depress and release the learn button twice. 5. The 210Rx will then enter the ‘time set mode’ 6. LED1 will illuminate, indicating that output 1 t ime delay is to be set. 7. Using a fine screwdriver, adjust potentiometer V R1. 8. An indication of the time delay set is shown by LED’s 9-15. After setting the timed output the unit must be pow ered down and option link header J8 removed before it can be used.
1.3 Erasing the 210Rx Receiver Outputs (Return to F actory Default State)
- To completely erase the 210Rx decoder’s memory, press and hold the 210Rx learn switch. 2. The learn LED (LED 17) will illuminate 3. Hold the Learn switch until the learn LED exting uishes (approx 10 seconds). 4. Release the learn button and all the output LED’ s 1-16 will now flash alternately to indicate that all encoder data has been erased and the 210Rx has returned to factory default state. Note: It is not possible erase individual transmitters.
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 5 PRO Professional Radio Control Series COM NO NC Relay Connections when Transmitter NOT Operating COM NO NC Relay Connections when Transmitter OPERATING
1.4 Connecting output Modules to the 210 Receiver
The receiver has 16 outputs. These are connected to the relay output module via a ribbon cable. The outputs are presented according to the following table.
1.5 Relay Outputs
Each output relay provides an isolated switch. Conn ections are Common (COM), Normally Open (NO), Normally Closed (NC).
2 Antenna and Range
2.1 Antenna
The system includes an antenna, It is situated within the enclosure (to save penetrating the enclosure) If the range is inadequate then it may be necessary to mount the antenna protruding from the enclosure . This may be easily fitted using the provided panel mount BNC socket. The antenna cable may be extended however please note that typically there is a 50% range reduction with every 3metres of coax cable used! For increasing range performance a +3dB gain antenna is available. This is supplied with wall mounting bracket and 2metres of coax cable, it plugs in directly to the BNC connector.
2.2 Range
The antenna choice and position directly controls t he system range. Keep it clear of other metal in th e system. The best position is protruding from the top of the product. This is often not desirable for practical or ergonomic reasons and thus a compromise may be needed. If an internal antenna must be used then try to keep it a way from other metal items, and in particular large one s like transformers, batteries and PCB tracks and e arth planes. Note that the space around the antenna is as import ant as the antenna itself. All radio systems are de pendant on a radio signal being received through airspace. The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions.
2.3 Signal integrity
In systems where many encoders are in close proximity there may be occasions when, due to signal overlay between encoders, it is difficult or impossible to guarantee system integrity. In such circumstances it is the responsibility of the installer to ensure that the system performance is adequate for the purposes of the installation. 210 receiver Connector O/P Channels 1 1 - 4 2 5 – 8 3 9 – 12 4 13 – 16
DS200PRO-3 June ’07 ©2007 RF Solutions Ltd, www. rfsolutions.co.uk Page 6 PRO Professional Radio Control Series Technical Specifications Transmitters
204 Series
Battery 2 x CR2016 Lithium Cell
205 Series
Dimensions 4 Switch unit 105 x 58 x 18 (not incl uding ANT) 8 / 16 Switch unit 250 x 90 x 41 (not including AN T) Battery 4 Switch unit 2x AAA 8 / 16 Switch unit 2 x CR2016 Lithium Cell Receiver Unit Dimensions 315 x 235 x 130mm Insulation class II Sealed hinged lid screws DIN Rails mounted on steel plate Integrated 12Vdc moulded Power Supply
5 Amp Fused terminal block
Material GW PLAST 120 °C A 12Vdc power supply is incorporated. 12Vdc is presented on a fused terminal block. A Gland is supplied to enable power to enter the enclosure. Learning Capacity: The receiver has the capacity t o learn upto 50 units (Where 1 unit is defined as a button on a transmitter) Dimensions External 315 x 235 x 130mm Internal 300 x 220 x 120mm DIN Rail length 1 285mm DIN Rail length 2 180mm Technical Specifications Input Voltage 110-240Vac Output Voltage 12Vdc +/-5% Output Current 1A Output Polarity: White Dashed Wire =+12V Storage Temperature: -10 to +70 o Celsius. Operating Temperature: 0 to +55 o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage: 12V Supply 10 12 16 V Supply Voltage: 24V Supply 21 24 30 V Supply Current : Quiescent 25 mA Time from Tx Switch depressed to 210Rx output 10 0 mS Time from Tx Switch release to Decoder output 20 0 mS Switched output Voltage (I out = 1mA) Logic Low Logic High 3.5 0.2 3.8 0.8 V V