Visit product website  DATA SHEET Type 8697  Pneumatic control unit for decentralised automation of process valves ELEMENT Type 8640  Modular valve island for pneumatics Type 8644  AirLINE SP electro­ pneumatic automation system Type 6014  Plunger valve 3/2­way direct acting Type 8840  Modular process valve cluster distributor and collector Standard | EU | en | 2024 ­ 03 ­ 19 | 07 Pneumatically operated 3/2-way seat valve CLASSIC

  • For mixing or distributing of media Controlled by a pilot valve or centrally by a valve island Flow optimised body in stainless steel Long life time and maintenance free operation The Bürkert 3/2­way seat valve Type 2006 consists of a pneumatically operated CLASSIC actuator and a 3-way valve body. The actuator is available in two differ ­ ent materials, PA or PPS, depending on the ambient temperature. Interchanging of pressure and working connections enables different fluidic control functions, such as the mixing or distributing of media. The flow-optimised valve body Type 2006 allows excellent flow values. The tried-and-tested self-adjusting pack­ ing gland secures a high level of tightness and thus ensures reliable operation over years. The 3 way valve Type 2006 is controlled by a pilot valve or by centralised automation using a valve island. It can be equipped easily with electrical position feedback. For the user, the compact Type 2006 is thus often an economic alterna­ tive instead of two single shut-off valves. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type 2006 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 14Visit product website  Table of contents 1. General technical data 3 Control functions 2.2. Pin assignment for flow modes of operation C, D, E and F 3. Approvals and conformities 5 3.2. Conformity 3.3. Standards 3.4. Explosion protection 3.5. Drinking water 3.6. Foods and beverages/Hygiene 3.7. Others Oxygen Fuel gases 4. Materials 7 4.2. Material specifications 5. Dimensions 8 6. Performance specifications 9 Pilot pressure diagram 6.2. Operating limits Operating limits ambient and medium temperature 7. Ordering information 11 7.2. Bürkert product filter 7.3. Bürkert Product Enquiry Form 7.4. Ordering chart threaded connection 7.5. Ordering chart accessories 3/2-way pilot valves with banjo bolts Cable plug Type 2507, Form B or Type 2508, Form A Type 8697 pneumatic position feedback unit Adapter kits

3 | 14Visit product website  1. General technical data Product properties Dimensions Further information can be found in chapter “5. Dimensions” on page 8 Material Body Stainless steel 316L Actuator PA (PPS on request) Seal PTFE Packing gland (with silicone grease) PTFE V ­ rings with spring compensation Nominal diameter (port connection) DN 15…50 Performance data Nominal pressure PN 16 (body) Pilot pressure Max 10 bar(g) bar(g) with actuator size Ø 125 Medium data Medium Steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, organic solvents, oxygen and fuel gases of families I, II and III in accordance with the Gas Appliances Regulation (EU) 2016/426 Medium temperature - 10…+ 180 Viscosity Max. 600 mm2/s Control medium Air, neutral gases Process/Port connection & communication Port connection Threaded connection G (DIN ISO 228 NPT (ASME B1.20.1) (Rc on request) Approvals and conformities Further information can be found in chapter “3. Approvals and conformities” on page 5 Material certificate 2.2, 3.1 Environment and installation Ambient temperature PA actuator - 10…+ PPS actuator Actuator size Ø 50 (D)…80 (F) mm + 5…+ 140 Actuator size Ø 125 (H) mm + 5…+ °C (short-term…+ 140 °C) Installation position As required, preferably with actuator in upright position

4 | 14Visit product website  2. Control functions 2.1. Control function Symbol Description 1(P) 3 Control function C (CF C) Pneumatically operated 3/2 way process valve When de energised, pressure port 1 closed, service port 2 exhausted 3(P) 1 Control function D (CF D) Pneumatically operated 3/2 way process valve When de energised, pressure port 3 connected to service port 2, exhaust port 1 closed 1(P1) 3(P2) Control function E (CF E) Pneumatically operated 3/2 way mixer valve When de energised, pressure port 3 connected to service port 2, pressure port 1 closed 1 3 2(P) Control function F (CF F) Pneumatically operated 3/2 way distributor valve When de energised, pressure port 2 connected to service port 3, service port 1 closed 2.2. Pin assignment for flow modes of operation C, D, E and F Note: Actuator with control function A When de energised, port connection 1 is closed with spring Flow modes of operation Connection 1 2 3 C P A R D R A P E P1 A P2 F A P B A, B Service ports P, P1, P2 Pressure ports R Exhaust port

5 | 14Visit product website  3. Approvals and conformities 3.1. General notes

  • The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below mentioned approvals or conformities. 3.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. This includes the following directives: Pressure Equipment Directive 2014/68/EU Machinery Directive 2006/42/EG 3.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 3.4. Explosion protection Approval Description Optional: Explosion protection As a category 2 device suitable for zone 1/21 and zone 2/22 (optional). ATEX: EPS 18 ATEX 2 008 X II 2G Ex h IIC T4…T2 Gb II 2D Ex h IIIC T135 °C…T300 °C Db IECEx: IECEx EPS 18.0007 X Ex h IIC T4…T2 Gb Ex h IIIC T135 °C…T300 °C Db Temperature class T2 T3 T4 Permissible surface temperature + 300 °C + 200 °C + 135 Ambient temperature Restrictions from the device 40…+ °C - 40…+ °C - 40…+ Maximum medium temperature Restrictions from the device 230 °C + 185 °C + 125 3.5. Drinking water Conformity Description Suitable for use in drinking water applications The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV). Stainless steel body PF39: Suitable for products with medium temperature up to 85 °C (hot water)

6 | 14Visit product website  3.6. Foods and beverages/Hygiene Conformity Description FDA FDA – Code of Federal Regulations (valid for the variable code PL02) All wetted materials are compliant with the Code of Federal Regulations published by the FDA (Food and Drug Administration, USA) according to the manufacturer‘s declaration. EC Regulation 1935/2004 of the European Parliament and of the Council (valid for the variable code PL01, PL02) All wetted materials are compliant with EC Regulation 1935/2004/EC according to the manufacturer‘s declaration. 3.7. Others Oxygen Conformity Description Optional: Suitability for oxygen (valid for the variable code NL02) The products are suitable for use with gaseous oxygen, according to the manufacturer‘s declaration. Fuel gases Conformity Description Fuel gases (valid for the variable code PO20) The products comply with: Regulation (EU) 2016/426 – Appliances burning gaseous fuels and DVGW DIN EN 161 (Automatic shut-off valves for gas burners and gas appliances) and DIN EN 16678 Class D (Safety and control devices for gas burners and gas burning appliances – Automatic shut-off valves for operating pressure of above 500 kPa up to and including 6 300 kPa)

7 | 14Visit product website  4. Materials 4.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check 4.2. Material specifications No. Element Material

1 Transparent cap Polycarbonate (PC)

(with PPS actuator: PSU) 2 O Ring FKM

3 Actuator Polyamide (PPS)

4 Pilot air ports G

¼ Stainless steel 1.4305

5 Piston seal NBR (with PPS actuator: FKM)

6 Spindle seal PTFE

7 Pipe

1.) Stainless steel 1.4401 / 316 Stainless steel 1.4404 / 316L 2.) 8 Spring Stainless steel 1.4310

9 Nipple

1.) Stainless steel 1.4401 / 316 Stainless steel 1.4404 / 316L 2.)

10 Wiper PTFE

3.) 11 Valve body Stainless steel 1.4404 / 316L 12 Spindle Stainless steel 1.4404 / 316L 13 Seal holder Stainless steel 1.4404 / 316L

14 Seat seal PTFE

15 Seat nipple Stainless steel 1.4404 / 316L 1.) In one piece for the actuator size 63 mm to 125 mm 2.) For actuator size 63 mm to 125 mm 3.) For actuator size 125 mm

8 | 14Visit product website  5. Dimensions E A H T D D Nominal diameter (port connection) Actuator size Ø Port connection D A E H T 15 50 (D) G ½ 85 64 178 54 63 (E) 80 220 54 20 50 (D) G ¾ 85 64 178 54 63 (E) 80 220 54 25 63 (E) G 1 105 80 220 54 32 80 (F) G 1¼ 130 101 249 68 125 (H) 158 345 68 40 63 (E) G 1½ 130 80 226 68 80 (F) 101 249 68 125 (H) 158 345 68 50 125 (H) G 2 150 158 352 72

9 | 14Visit product website  6. Performance specifications 6.1. Fluidic data Pilot pressure diagram Note: CF A, flow direction 3 à 2 Actuator size Ø 50 mm Maximum control pressure 10 bar(g) Actuator size Ø 63 mm Maximum control pressure 10 bar(g) Pilot pressure [bar(g)] 0 1 2 3 4 5 6 7 8 9 10 Operating pressure [bar(g)] at connection 3 Nominal diameter: DN15/20 0 1 2 3 4 5 6 7 8 9 10 DN15/20 DN25 Pilot pressure [bar(g)] Operating pressure [bar(g)] at connection 3 Nominal diameter: Actuator size Ø 80 mm Maximum control pressure 10 bar(g) Actuator size Ø 125 mm Maximum control pressure 7 bar(g) 0 1 2 3 4 5 6 7 8 9 10 DN32/40 Pilot pressure [bar(g)] Operating pressure [bar(g)] at connection 3 Nominal diameter: DN32/40 DN50 0 1 2 3 4 5 6 7 8 9 10 Pilot pressure [bar(g)] Operating pressure [bar(g)] at connection 3 Nominal diameter:

10 | 14Visit product website  6.2. Operating limits Operating limits ambient and medium temperature Note: For sizes 50 (D) and 63 (E) PA actuators, the combination of maximum medium temperature and maximum ambient temperature is shown in the following diagram: Actuator size Ø 50 mm Maximum control pressure 10 bar(g) Actuator size Ø 63 mm Maximum control pressure 10 bar(g) 100 120 140 160 180 200 Ambient temp. °C Medium temperature °C 100 120 140 160 180 200 Ambient temp. °C Medium temperature °C

11 | 14Visit product website  7. Ordering information 7.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 7.3. Bürkert Product Enquiry Form Note: Please see our Product Enquiry Form for a full explanation of our specification key. Bürkert Product Enquiry Form – Your enquiry quickly and compactly Would you like to make a specific product enquiry based on your technical requirements? Use our Product Enquiry Form for this purpose. There you will find all the relevant informa­ tion for your Bürkert contact. This will enable us to provide you with the best possible advice. Fill out the form now

12 | 14Visit product website  7.4. Ordering chart threaded connection Note: Port 1 closed by spring action Other variants are available on request Control function Nominal diameter (port connection) Port con- nection Actuator size Ø KV value water Pilot pres- sure min. Operating pressure max. up to 180 Weight Article no. PA actuator PPS actuator à 2 2 à 3 1 à 2 2 à à DN [mm] [m 3/h] [bar(g)] [bar(g)] [kg] EN ISO 228 A (CF A) see control functions 1.) 2.) 15 G ½ 50 (D) 7 4.5 4.4 11 16 1.3 287191  287202  63 (E) 8 4.5 4.7 16 16 1.6 287192  287203 20 G ¾ 50 (D) 9 6.2 4.4 11 16 1.3 287193  287204 63 (E) 11 5.6 4.7 16 16 1.6 287194  287205 25 G 1 63 (E) 17 11 4.9 10 16 2.1 287195  287206 32 G 1¼ 80 (F) 32 21 6.0 9 16 4.3 287196  287207 125 (H) 35 24 3.4 14 16 8.1 287197  287208 40 G 1½ 80 (F) 35 24 6.0 9 16 4.3 287199  287210 125 (H) 35 24 3.4 14 16 8.1 287200  287211 50 G 2 125 (H) 51 35 4.3 10 16 9.5 287201  287212 ANSI B 1.20.1 A (CF A) see control functions 1.) 2.) 15 NPT ½ 50 (D) 7 4.5 4.4 11 16 1.3 292542  292553  15 63 (E) 8 4.5 4.7 16 16 1.6 292543  292554

20 NPT

¾ 50 (D) 9 6.2 4.4 11 16 1.3 292544  292555 20 63 (E) 11 5.6 4.7 16 16 1.6 292545  292556

25 NPT

1 63 (E) 17 11 4.9 10 16 2.1 292546  292557

32 NPT

1¼ 80 (F) 32 21 6.0 9 16 4.3 292547  292558 32 125 (H) 35 24 3.4 14 16 8.1 292548  292559

40 NPT

1½ 80 (F) 35 24 6.0 9 16 4.3 292550  292560 40 125 (H) 35 24 3.4 14 16 8.1 292551  292561

50 NPT

2 125 (H) 51 35 4.3 10 16 9.5 292552  292562 1.) For more information, refer to the chapter “2. Control functions” on page 4 . 2.) See “2.2. Pin assignment for flow modes of operation E and on page Further versions on request Process connection Rc thread

13 | 14Visit product website  7.5. Ordering chart accessories 3/2-way pilot valves with banjo bolts Note: Seal material of valve is FKM, seal material of banjo bolt is NBR For further accessories see the accessories data sheet Type 2XXX Valve for actuator size Ø Type Pressure inlet P (valve body) Working port A (banjo bolt) Nominal diameter (port connection) QNn value air Pressure range Electrical coil connection industry standard Power consump- tion Article no. per voltage/frequency [V/Hz] [mm] [mm] [l/min] [bar(g)] [W] 024/DC 230/50 50 (D)… 63 (E) 6012P Pipe fitting Ø 6 mm G ¼ 1.2 48 0…10 Form B 4 552283  552286 50 (D)… 125 6014P G ¼ G ¼ 2 120 0…10 Form A 8 424103  424107 Cable plug Type 2507, Form B or Type 2508, Form A Variant Voltage Article no. Type 2507, Form B industry standard, without circuitry (Type

6012 P) 0…250

2508, Form A according to DIN EN 175301 803, without circuitry (Type

6014 P, Type

0331P) 0…250 V 008376

14 | 14Visit product website  Type 8697 pneumatic position feedback unit Note: cULus only valid for versions without ATEX approval End position feedback Electrical connection ATEX / IECEx Cat. 3D/G Zone 1.) ATEX / IECEx Cat. 2D/G Zone 2.) ATEX/ IECEX Cat. 2G Zone 3.) cULus Article no. Actuator series CLASSIC Type 20xx Induc- tive switch 3-wire PNP Induc- tive switch 2-wire NAMUR Induc- tive switch 2-wire V DC Micro switch V DC Micro switch 50…250 V AC/DC Feed- back status LEDs Feedback (without pilot valve) 2 – – – – Yes Cable gland – – – Yes 248827 2 – – – – Yes Cable gland Yes – – – 255851 2 – – – – Yes M12 multipole Yes – – – 255858 2 – – – – Yes M12 multipole – – – Yes 250472 – 2 – – – Yes Cable gland – Yes – – 248831 – 2 – – – Yes Cable gland – – Yes – 255863 – – 2 – – Yes Cable gland – – – Yes 248826 – – 2 – – Yes Cable gland Yes – – – 255850 gland – – – Yes 248833 gland – – – Yes 248825 1.) II 3D Ex tc IIIC T135 / II 3G Ex nA IIC T4 Gc 2.) II 2D Ex ia IIIC T135 °C IP64 / II 2G Ex ia IIC T4 Gb 3.) II 2G Ex ia IIC T4 Gb Adapter kits Note: For further information, please refer to data sheet Type 8697 Description Actuator size Control function Article no. Adapter kit for Type mm Universal 682264 Adapter kit for Type 8697 Ø 125 mm Universal 682265