1923144 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. 1-level terminal block with double connection on one side, cross section: 0.2 - 4 mm2, AWG: 24 - 12, width: 6.2 mm, color: Yellow Commercial data Item number 1923144 Packing unit 50 pc Minimum order quantity 50 pc Sales key BE12 Product key BE1212 GTIN 4017918269098 Weight per piece (including packing) 12.59 g Weight per piece (excluding packing) 12.59 g Customs tariff number 85369010 Country of origin CN UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 1 (10)
Product type Multi-conductor terminal block Number of positions 1 Number of connections 3 Number of rows 2 Potentials 1 Insulation characteristics Overvoltage category III Degree of pollution 3 Electrical properties Rated surge voltage 6 kV Maximum power dissipation for nominal condition 1.02 W Connection data Number of connections per level 3 Nominal cross section 4 mm² 1 level Screw thread M3 Stripping length 8 mm Internal cylindrical gage A4 Connection in acc. with standard IEC 60947-7-1 Conductor cross section rigid 0.2 mm² ... 4 mm² Cross section AWG 24 ... 12 (converted acc. to IEC) Conductor cross section flexible 0.2 mm² ... 4 mm² Conductor cross section, flexible [AWG] 24 ... 12 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 4 mm² Cross-section with insertion bridge, rigid 4 mm² Cross-section with insertion bridge, flexible 4 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve Nominal current 32 A (with 4 mm² conductor cross section) Maximum load current 32 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.) UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 2 (10)
Nominal voltage 500 V (With tightened clamping screws) Nominal cross section 4 mm² Ex data Rated data (ATEX/IECEx) Identification II 2 G Ex eb IIC Gb Operating temperature range -50 °C ... 110 °C
1923034 D-UK 5-TWIN
9911501 UK 5-TWIN DECKELSEGMENTGY7042
1205053 SZS 0,6X3,5
Ex temperature increase 33 K (32 A / 4 mm²) Rated voltage 275 V Rated insulation voltage 250 V output (Permanent) Ex level General Rated current 32 A Maximum load current 32 A Contact resistance 0.34 mΩ Ex connection data General Stripping length 8 mm Nominal cross section 4 mm² Rated cross section AWG 12 Connection capacity rigid 0.2 mm² ... 4 mm² Connection capacity AWG 24 ... 12 Connection capacity flexible 0.2 mm² ... 4 mm² Connection capacity AWG 24 ... 12 2 conductors with the same cross-section AWG rigid 24 ... 16 2 conductors with the same cross-section AWG flexible 24 ... 16 Dimensions Width 6.2 mm End cover width 2 mm Height 50.5 mm Depth on NS 32 52 mm Depth on NS 35/7,5 47 mm Depth on NS 35/15 54.5 mm Material specifications Color yellow (RAL 1018) Flammability rating according to UL 94 V0 UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 3 (10)
Insulating material group I Insulating material PA Static insulating material application in cold -60 °C Relative insulation material temperature index (Elec., UL 746 B) 130 °C Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Smoke gas toxicity NFPA 130 (SMP 800C) passed Electrical tests Surge voltage test Result Test passed Temperature-rise test Requirement temperature-rise test Increase in temperature ≤ 45 K Result Test passed Short-time withstand current 4000000 mm² 0.00048 kA Result Test passed Power-frequency withstand voltage Test voltage setpoint 1.89 kV Result Test passed Mechanical properties Mechanical data Open side panel Yes Mechanical tests Mechanical strength Result Test passed Attachment on the carrier DIN rail/fixing support NS 32/NS 35 Test force setpoint 1 N Result Test passed Test for conductor damage and slackening Rotation speed 10 (+/- 2) rpm Revolutions 135 0.2 mm² / 0.2 kg 1.5 mm² / 0.4 kg Conductor cross section/weight 4 mm² / 0.9 kg UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 4 (10)
Environmental and real-life conditions Needle-flame test Time of exposure 30 s Result Test passed Ambient conditions Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) Ambient temperature (assembly) -5 °C ... 70 °C Ambient temperature (actuation) -5 °C ... 70 °C Permissible humidity (operation) 20 % ... 90 % Permissible humidity (storage/transport) 30 % ... 70 % Standards and regulations Connection in acc. with standard IEC 60947-7-1 Mounting NS 35/7,5 NS 35/15 Mounting type NS 32 UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 5 (10)
UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 6 (10)
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1923144 DNV Approval ID: TAE00001CT CSA Approval ID: 13631 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
300 V 30 A 22 - 10 -
IECEE CB Scheme Approval ID: NL-65052 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
500 V 32 A - - 4
cULus Recognized Approval ID: E60425 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group B Field wiring 300 V 30 A 30 - 10 - Factory wiring 300 V 35 A 30 - 10 - Use group C Field wiring 150 V 30 A 30 - 10 - Factory wiring 150 V 35 A 30 - 10 - KEMA-KEUR Approval ID: 71-119845 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 500 V 32 A - 0.2 - 4 CSA Approval ID: 13631 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group B
300 V 30 A - -
150 V 30 A - -
300 V 10 A - -
UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 7 (10)
cUL Recognized Approval ID: E192998 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
150 V 30 A 30 - 10 -
UL Recognized Approval ID: E192998 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 8 (10)
ECLASS-11.0 27141120 ECLASS-13.0 27250101 ETIM ETIM 9.0 EC000897 UNSPSC UNSPSC 21.0 39121400 UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 9 (10)
Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes, No exemptions China RoHS EFUP-EEnvironment friendly use period (EFUP) No hazardous substances above the limits EU REACH SVHC REACH candidate substance (CAS No.) No substance above 0.1 wt% Phoenix Contact 2025 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com UK 5-TWIN YE - Feed-through terminal block 1923144 https://www.phoenixcontact.com/us/products/1923144 Mar 17, 2025, 12:28 AM Page 10 (10)