180ACMOP GAPTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 2 180ACMOP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. Approval Model Power [W] Output voltage[V] Load convection [A, max] 15CFM forced air [A, max] Ripple&Noise [mV, Vp-p] Output Regulation [%] Efficiency [@115VAC, %, typ] UL/CE 180ACMOP_12S4 180 12 10 15 240 ±3 >87 UL/CE 180ACMOP_15S4 180 15 8 12 240 ±3 >87 UL/CE 180ACMOP_19S4 180 19 6.32 9.48 240 ±2 >87 UL/CE 180ACMOP_24S4 180 24 5 7.5 240 ±2 >87 UL/CE 180ACMOP_28S4 180 28 4.29 6.43 240 ±2 >87 UL/CE 180ACMOP_48S4 180 48 2.5 3.75 240 ±2 >87 180ACMOP_S4 Series 180W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Universal input: 90~264VAC High efficiency: >87% typical Short circuit protection (SCP) Over load protection (OLP) Over voltage protection (OVP) No load power consumption Compact, high power density Medical 60601-1 3rd Edition MOPP and ITE approved Meet DOE level VI & ErP Tier 1 requirements UL 60950-1 AC-DC Converter 180 Watt The 180ACMOP_S4 series is a compact size power converter offered by Gaptec. It features universal input voltage, taking AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, meets IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and is widely used in medical instru - mentation and critical applications in commercial and industrial elect - ronic equipment. Input specifications Input voltage range 90-264 VAC Input frequency 47~63Hz Power factor 115VAC
- 0.95A (max) 230VAC
- 0.9A (max) Input current 115VAC
- 3A (max) 230VAC
- 1.5A (max) Inrush current (cold start @25°C) 115VAC
- 50A (typ) 230VAC
- 100A (typ) Leakage current < 100µA/264VAC Recommended external fuse
- 2A • High Breaking capacity (pending) Example: 180ACMOP_05S4 180= 180Watt; AC= AC-DC; MOP= series; 5Vout; S= Single Output; 4= 4kVAC Note: 1. This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. At 25°C including initial tolerance, line voltage, load currents and output volta- ges adjusted to factory settings. 3. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector. Output specifications Item Test conditions Min Typ Max Units Output power with 15CFM forced air cooling 180 W Output voltage accuracy Full load ±2 % Hold-up time @load 75%, 115VAC 20 ms Protection specifications Short circuit protection Protection type: Auto-recovery Over-voltage protection Protection type: Latching type. AC Recycle Over-load protection Protection type: 110% to 150% maximum rating, Auto-recovery
GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 2 180ACMOP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 180ACMOP_S4 Series 180W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Common specifications Operating temperature range Convection cooling : 0 to +60°C (Derate linearly 2.5% per °C from 41 to 60°C) 15 CFM Forced air : 0 to +60°C (Derate linearly 2.5% per °C from 51 to 60°C) Storage temperature range -40°C ~ +85°C Humidity (non-condensing) 95% MAX Cooling Free air convection I/O-isolation voltage 4000VAC EMC / EMI / Conducted and radiated EMI EN55011 class B (Radiation Class A for 180ACMOP_S4 series) EMC / EMS / ESD IEC/EN 61000-4-2 Contact ±8KV / Air ±15KV perf. Criteria B EMC / EMS / Radiated Immunity IEC/EN 61000-4-3 3V/m perf. Criteria A EMC / EMS / Fast Transient IEC/EN 61000-4-4 ±2kV perf. Criteria B EMC / EMS / Surge IEC/EN 61000-4-5 Line to Line: ±2KV Line to PE: ±4KV perf. Criteria B EMC / EMS / Conducted immunity IEC/EN 61000-4-6 10Vr.m.s perf. Criteria A EMC / EMS / PFMF IEC/EN 61000-4-8 30A/m perf. Criteria A EMC / EMS / Dips IEC/EN 61000-4-11 30% / 500ms perf. Criteria B EMC / EMS / Interruption EN61000-4-11 >95% 5000ms EMC standards EN60601-1-2 FCC Part 18 Class B EN 55011 Class B CE Safety standards 60601-1 3rd Edition CSA-C22.2 No.60601-1 3rd Edition EN60601-1 3rd Edition IEC 60601-1 3rd Edition MTBF 100,000 h @25°C Package 27 × W76.2 × H30.0 mm Weight 350g Mechanical dimensions Matching connectors: CN1: Input connector JST B3P-VH-B pitch: 7.92mm or equivalent, mates with JST VHR-3N or equivalent PIN Single
1 AC Line
2 AC Neutral
CN2: Output Connector JST B4P-VH-B pitch: 3.96mm or equivalent, mates with JST VHR-4N or equivalent PIN Single 1 -Vo 2 -Vo 3 +Vo 4 +Vo