Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Coupler connector, straight short, for standard and SPEEDCON interlock, M23, number of positions: 5+PE, contact connection type: Pin, shielded: yes, degree of protection: IP67, cable diameter range: 7.5 mm ... 9 mm, Compatible with mating connectors with SPEEDCON or M23 standard knurled nuts, number of positions: 6, connection method: Crimp connection, series: SF, Alternative product in accordance with RoHS II without Exemption 6c (Pb <0.1%) item no.: 1241894 Your advantages Consistent EMC protection for reliable connection solutions in the industrial environment• Crimping connection: vibration- and temperature-resistant assembly Flexible use: reliably connect various cable diameters Commercial data Item number 1605494 Packing unit 1 pc Minimum order quantity 1 pc Sales key AB35 Product key ABRBFG Catalog page Page 155 (C-2-2019) GTIN 4046356253130 Weight per piece (including packing) 107.6 g Weight per piece (excluding packing) 107.6 g Customs tariff number 85366990 Country of origin DE SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 1 (16)
General Order crimp contacts 6 x Ø 2 mm separately Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
- WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
- WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
- The products are suitable for applications in plant, controller, and electrical device engineering.
- When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
- Assembled products may not be manipulated or improperly opened.
- Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
- When using the product in direct connection with third-party manufacturers, the user is responsible.
- For operating voltages > 50 V AC, conductive connector housings must be grounded
- Ensure that the protective or functional ground has been properly connected. are applicable when combining several circuits in a cable and/or connector
- Only use tools recommended by Phoenix Contact
- The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
- Operate the connector only when it is fully plugged in and interlocked.
- Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
- Observe the minimum bending radius of the cable. Lay the cable without twisting it.
- The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting Safety note SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 2 (16)
warnings (e.g. DIN EN ISO 13732-1:2008-12). Mounting Connection method Crimp connection Product properties Product type Circular connector (cable-side) Number of positions 6 Connection profile 5+PE Application Power Series SF Shielded yes Coding N Thread type M23 Material specifications Seal material FPM Housing material Turned parts: copper zinc alloy (CuZn), die-cast parts: zinc (GD- Zn) Insulator material PA 6.6 Gasket and O-ring material FPM Housing material Metal Connection data Conductor connection Connection method Crimp connection Electrical properties Contact Contact diameter 2 mm Max. current 30 A Nominal voltage UN 630 V Overvoltage category III Degree of pollution 3 Rated surge voltage 6 kV Contact Contact diameter 2 mm Max. current 30 A Nominal voltage UN 630 V Overvoltage category III Degree of pollution 3 Rated surge voltage 6 kV Connector SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 3 (16)
External cable diameter 7.5 mm ... 9 mm Environmental and real-life conditions Ambient conditions Degree of protection IP67 Ambient temperature (operation) -40 °C ... 125 °C Altitude 3000 m SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 4 (16)
60,1 Dimensional drawing Diagram 0 10 20 30 40 50 60 70 80 90 100 110 120130 I [A] [°C] SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 5 (16)
SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 6 (16)
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1605494 cUL Recognized Approval ID: E153698-20041116 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
600 V 18 A - 12 -
UL Recognized Approval ID: E153698-20041116 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
600 V 27 A - 12 -
EAC Approval ID: B.01687 cULus Recognized SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 7 (16)
ECLASS-11.0 27440102 ECLASS-12.0 27440116 ECLASS-13.0 27440116 ETIM ETIM 8.0 EC002635 UNSPSC UNSPSC 21.0 39121400 SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 8 (16)
Environmental product compliance REACh SVHC Lead 7439-92-1 Environmentally Friendly Use Period = 50 yearsChina RoHS For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 9 (16)
SF-7RP2000 - Crimp contact 1605646 https://www.phoenixcontact.com/us/products/1605646 Crimp contact, Pin, turned, Single contact, contact diameter: 2 mm, crimp range: Exemption 6c (Pb <0.1%) item no.: 1241951 SF-7PP2000 - Crimp contact 1605634 https://www.phoenixcontact.com/us/products/1605634 Crimp contact, Pin, turned, Single contact, contact diameter: 2 mm, crimp range: 0.25 mm2 ... 1 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb <0.1%) item no.: 1241951 SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 10 (16)
SF-20KP004 - Crimp contact 1607376 https://www.phoenixcontact.com/us/products/1607376 5 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb <0.1%) item no.: 1241953 SF-7QP2000 - Crimp contact 1605639 https://www.phoenixcontact.com/us/products/1605639 Crimp contact, Pin, turned, Single contact, contact diameter: 2 mm, crimp range: 1 mm2 ... 2.5 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb <0.1%) item no.: 1241953 SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 11 (16)
https://www.phoenixcontact.com/us/products/1607449 Plastic protection cap, with eye, IP40 for connectors with M23 external thread, RF, SF series RC-Z2059 - Protective cap 1604225 https://www.phoenixcontact.com/us/products/1604225 Plastic protection cap for connectors with M23 external thread SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 12 (16)
https://www.phoenixcontact.com/us/products/1611797 Plastic protection cap, antistatic, for RF, SF, CA, RC series connectors, with M23 external thread SC-Z2319 - Metal protective cap 1605456 https://www.phoenixcontact.com/us/products/1605456 Metal protection cap for power connectors with M23 external thread SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 13 (16)
SC-Z2320 - Metal protective cap 1605457 https://www.phoenixcontact.com/us/products/1605457 Metal protection cap with steel wire for power connectors with M23 external thread SF-Z0064 - Color-coding 1620585 https://www.phoenixcontact.com/us/products/1620585 Color-coding, color: green SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 14 (16)
https://www.phoenixcontact.com/us/products/1620586 Color-coding, color: orange SF-Z0066 - Color-coding 1620587 https://www.phoenixcontact.com/us/products/1620587 Color-coding, color: black SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 15 (16)
SF-Z0068 - Square mounting flange 1620927 https://www.phoenixcontact.com/us/products/1620927 Square mounting flange, 4xM3, flange dimensions: 38 mm x 38 mm, series: SF, Alternative product in accordance with RoHS II without Exemption 6c (Pb <0.1%) item no.: 1244326 Phoenix Contact 2023 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com SF-5EP1N8A90A1 - Coupler connector 1605494 https://www.phoenixcontact.com/us/products/1605494 Oct 6, 2023, 5:40 AM Page 16 (16)