Visit product website  DATA SHEET Type 8741  Mass Flow Controller (MFC)/ Mass Flow Me- ter (MFM) for Gases Type 8905  Online Analysis System Type 8640  Customized Pneumatic Systems Solutions for the Processing Indus- tries Type 8644  Remote Process Actu- ation Control System AirLINE Type 8619  multiCELL - Multi-chan- nel and multi-function transmitter/controller 1000252581 | Standard | EU | en | 201909 | 08 Single phase primary switched power supply

  • Stabilised and adjustable output voltage
  • Parallel operation
  • Push-In terminals
  • Panel installation on mounting rails
  • DC OK Signalling Efficient, primary switched mode power supply in slim plastic housing. A power ful and flexible option that’s still light and compact. These power supply units are suitable for a highly diverse range of

applications

solar, measure- ment and control technology as well as industrial and building automation. The output voltage can be easily set using the rotary potentiometer on the fr ont of the housing. The DIN rail fastening method and push-in connection t erminals enable fast and secure mounting. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 1573 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 9Visit product website  Table of contents 1. Gener al technical data 3 2. Dimensions 5 2.2. Article no. 772362 2.3. Article no. 772698 2.4. Article no. 772898 3. Device/P rocess connections 7 P roduct installation 4.2. Assembly instruction 5. Or dering information 8 5.2. Bürkert product filter 5.3. Ordering chart

3 | 9Visit product website  1. Gener al technical data Product properties Dimensions Detailed information can be found in chapter “2. Dimensions” on page 5 Transient surge voltage protection (varis- tor) Yes Parallel operation Yes Serial operation Yes Signaling Signaling ‘DC OK’ (LED lit permanently gr een) Uout > 21.5 V T erminals Signaling Push-In, max 2.5 mm² Electrical data Input data Nominal Input Voltage AC 100…240 V Input Voltage range 85…264 V AC (120…372 V DC) Frequency range 47 Hz…63 Hz/0 Hz Inrush current limitation < 30 A, NTC Terminal input Push-In, max 2.5 mm² Output data Nominal Output Voltage 24 V DC Resistance to reverse feed max. (nominal load) Max 35 V DC Terminal Output Push-In, max. 2.5 mm² Appr ovals and certificates Protection class acc. to IEC

60529 IP20

16, EN 60950 EMC EN 61204 EN 60335 Safety extra-low voltage (SELV/PELV) IEC 60364 (DIN VDE 0100 410) CE acc. to 2004/108/EC and 2006/95/EC Yes Mounting on standard rail DIN EN 60715-TH35-5/7.5 Yes Environment and installation Storage Temperature °C… Requir ed minimum spacing (over/under) 50 mm Convection Cooling Yes

4 | 9Visit product website  1.1. T echnical data for articles 772361, 772362, 772898 and 772698 Product properties 772361 772362 772898 772698 Dimensions x H x D) 22.5 97.5 mm 45 97.5 mm 52 111 mm 55 127 161 mm W eight 128 g 210 g 390 g 930 g Signal contact DC OK (active high) Uout > 21.5 V max. 20 mA

24 V DC

Uout > 21.5 V max. 20 mA Uout > 21.5 V max. 20 mA relay, contact closed – – – Uout > 21.5 max. 30 V/1 A Electrical data Input data Input voltage derating - 2.5 %/V ac

95 V A

2.5 %/V ac 2.5 %/V ac 2.5 %/V ac

100 V A

C Nominal input current (nominal load)

0.49 A(100 V AC)/

0.28 A (240 V AC) 0.82 A (100 V AC)/ 0.48 A (240 V AC) 1.73 A (100 V AC)/ 0.95 A (240 V AC) 2.74 A (100 V AC)/ 1.25 A (230 V AC) Turn-on time after apply- ing the main voltage 2.3 Sec. (100 V AC)/ 0.74 Sec. (230 V AC) 0.5 Sec. (100 V AC)/ 0.27 Sec. (230 V AC) 0.5 Sec. (100 V AC)/ 0.2 Sec. (230 V AC) 1.3 Sec. (100 V AC)/ 0.25 Sec. (230 V AC) Mains buffering (nominal load) 20/120 ms (100/230 V A 20/120 ms (100/230 V A 15/80 ms (100/230 V AC) 15/17 ms (100/230 V AC) Recommended power circuit breaker (charac- teristic) 6 A, 10 A, 16 A (B,C) 6 A, 10 A, 16 A (B, C) 6 A, 10 A, 16 A (B,C) 10 A, 16 A (B,C) Output data Output voltage range 23…28.5 V DC 23…28.5 V DC 23…28.5 V DC contant power) 23…28.5 V DC Nominal output curr ent 1 A 2 A 3.8 A 10 A Output current limitation constant current Typ. 1.25…1.4 A Typ. 2.25…2.4 A Typ. 3.8…3.2 A Typ. 11…13 A Power losses (Stand-by/ nominal load)

1 W/4 W

(230 V A

1 W/6 W

(230 V A

2.8 W/14 W

(230 V A 6.6 W/24.4 W (230 V AC) Maximum power losses 5 W (100 V AC/24 V/1 A) 7 W (100 V AC/24 V/2 A) 20 W (100 V AC/91 W) 31.3 W (100 V A C/24 V/10 A) Efficiency Typ. % T yp. % T yp. % T yp. Ripple/noise T yp. mVss Typ. 20 mVss Typ. 20 mVss Typ. 50 mVss Protection against inter- nal surge voltage (OVP) Max. 39 V DC Max. 37 V DC Max. 40 V DC Max. 40 V DC Approvals and certificates Protection class acc. to EN 61140 II II II I UL UL 508 listed UL 508 listed UL 508 listed UL/CSA 60950 recog- nized (E213214), UL 508 list ed (E219022) UL 60950 1 UL 60950 recognized UL 60950 recognized UL 60950 recognized – Class 2 Output (UL Lim- ited Power Source, LPS) EN 60950 1 EN 60950 1 EN 60950 UL 1310 GL (in preparation) GL (Germanisher Llyod) classified, Enivronment category: EMC Environment and installation Ambient temperature - to device start at type-tested Derating - K °C - K °C - K °C - %/K (196…264 V A 2.5 %/K (85…195 V A Current rating at any mounting position Max. 0.7 A Max. 2.4 A Max.

2.4 A –

Humidity (no conden- sation) 5…96 % 5…96 % 5…96 % 5…96

5 | 9Visit product website  2. Dimensions 2.1. Ar ticle no. 772361 3.5 3 22.5 90.5772 361 772 361 2.2. Ar ticle no. 772362 3.5 90.5 772 362 772 362

6 | 9Visit product website  2.3. Ar ticle no. 772698 127 63.5 3 55 153.5 161 772 698772 698 2.4. Ar ticle no. 772898 3.5 3 52 103.5 111 772 898772 898

7 | 9Visit product website  3. Device/P rocess connections Assignment No. Element 1 DC Outputs (++--) and active ‘DC OK’ signal contact

2 LED

‘DC OK’

3 Setting of output voltage

4 AC Line input (L N) without earth1.) 1.) AC Line input (L N PE) for Article no. 772698 4. P roduct installation 4.1. Installation not es Note: Always disconnect the equipment from the mains supply, before commencing installation or wiring. Installation must be carried out according to the prevailing local conditions and safety regulations, national accident prevention r egulations and the generally accepted rules of technology. This equipment is a component designed for installation into electrical syst ems and machines and fulfils the requirements of the low voltage guidelines (2006/95/EG). The r equired minimum spacing to neighbouring components must be observed to guarantee the required cooling. 4.2. Assembly instruction No. Element

1 Tilt

2 Fit the unit over top hat rail

3 Slide it downward until it hits the stop

4 Press against the bottom front side for locking (click)

5 Shake the unit slightly to check the locking action

8 | 9Visit product website  5. Or dering information 5.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 5.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily Try out our product filter 5.3. Or dering chart Nominal Current Output Article no.

1 A 772361 

2 A 772362 

3.8 A 772898 

10 A 772698 

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Portugal Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab EmiratesArgentina Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau