119S1-433A RFSOLUTIONS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

DS119-5 June ‘06 ©2006 REG No 277 4001, ENGLAND. Page 1 119, 129

10209 KEELOQ REMOTE CONTROL SYSTEMS, 230Vac

Description

A Range of ‘ready to operate’ remote control systems supplied as either AM or FM and contain a transmitter and receiver decoder pair. Installation requires connections to power supply (230Vac Live and Neutral) and the output relay screw terminals. The output relays are activated by the key press on the transmitter encoder. The system utilises the Microchip Keeloq protocol, ensuring high security and reliability. The decoder has the capacity to learn up to 50 unique transmitters. These are memorised even if the power is removed. The decoder is supplied in an IP65 rated enclosure with Cable Gland and wall mounting lugs supplied

  • 1 – 2 Channel Remote Control Systems
  • 230Vac Supply
  • AM / FM / FMNB Remote Receiver Decoder ‰ AM Range upto 100m ‰ FM Range upto 200m ‰ FMNB Range upto 1000m
  • High Security Protocol
  • ‘Easy Learn’ Tx Encoder Feature
  • Easy Installation Via Screw Terminals.
  • Up to 50 Transmitters per System
  • 315 / 433 / 868 / 915 MHz Available
  • 2 Relays Rated 12A pk at 230Vac
  • Momentary or Latching Outputs
  • IP65 Rated Enclosure (Wall Mounting Lugs Supplied)
  • Requires No Radio Licence

DS119-5 June ‘06 ©2006 REG No 277 4001, ENGLAND. Page 2 119, 129 Part Number Description Transmitter Type Freq (MHz) Range (Metres) 119S1-433A AM RC System 1 ch 230Vac Pocket Keyfob 433.92 100 119S2-433A AM RC System 2 ch 230Vac Pocket Keyfob 433.92 100 Additional AM Transmitter Keyfobs Part Number Description Freq (MHz) Range (Metres) 110C1-433A Transmitter Keyfob, 1 switch 433.92 100 110C2-433A Transmitter Keyfob, 2 switch 433.92 100 FM Remote Controls Part Number Description Transmitter Type Freq (MHz) Range (Metres) 129S1-433F FM RC System 1 ch 230Vac Pocket Keyfob 433.92 150 129S2-433F FM RC System 2 ch 230Vac Pocket Keyfob 433.92 150 10209S1-433F FM RC System 1 ch 230Vac Handheld 433.92 200 10209S2-433F FM RC System 2 ch 230Vac Handheld 433.92 200 10209S1-525N FM NB RC System 1 ch 230Vac Handheld 434.525 1000 10209S2-525N FM NB RC System 2 ch 230Vac Handheld 434.525 1000 Additional FM Transmitter Keyfobs Part Number Description Freq (MHz) Range (Metres) 120T1-433F Transmitter Keyfob 1 switch 433.92 150 120T2-433F Transmitter Keyfob 2 switch 433.92 150 102C1-433F FM Transmitter encoder 1 switch 433.92 200 102C2-433F FM Transmitter encoder 2 switch 433.92 200 102C1-525N FM Transmitter encoder 1 switch 434.525 1000 102C2-525N FM Transmitter encoder 2 switch 434.525 1000 ** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%

DS119-5 June ‘06 ©2006 REG No 277 4001, ENGLAND. Page 3 119, 129 Each of the transmitter switches maps directly to the relay outputs. (SW1 to RLY1, SW2 to RLY2) Each output relay provides an isolated switch. C onnections are Common (COM), Normally Open (NO) and Normally Closed (NC). The jumper links ( LK1, LK2 ) configure the outputs to be momentary or latching. LK1 LK2 O/P 1 O/P2 Open Open Mom Mom Open Connected Mom Latch Connected Open Latch Mom Connected Connected Latch Latch Note : In momentary mode the relay will operate for as long as the transmitter switch is held on. Learning a new Transmitter Encoder To enter and activate the learn mode the following sequence must be performed. 1. Power the receiver unit up and wait 10secs fo r the unit to enter ‘normal operation’ mode. 2. Switch the receiver unit OFF and then ON again in ~1sec intervals four times finally leaving the unit powered up. 3. After 5secs until a ‘beep’ sound is heard. 4. The unit is now in ‘learn’ Mode. 5. Briefly press a button on the transmitte r, the receiver unit will ‘beep’ twice. 6. Briefly Press the transmitter button again, he receiver unit will ‘beep’ three times. 7. Wait 10sec for the unit to return to ‘normal operation’ mode. 8. The transmitter is now ‘learnt’ to the receiver unit and will operate the output relays. Erasing Transmitter Encoders form Memory To enter and activate the erase mode the following sequence must be performed. 1. Power the receiver unit up and wait 10secs fo r the unit to enter ‘normal operation’ mode. 2. Switch the unit off and then on again in ~1sec inte rvals six times finally leaving the unit powered up. 3. Wait 5secs until a ‘ticking’ sound is heard for a period of 10secs by the operation and release of one of the relays. 4. Wait 10secs for the receiver unit to return to ‘normal’ mode 5. The unit has now erased all encoder data. Note During Learn and Erase the relays should not be connec ted to equipment that will be harmed by rapid changes of the relay polarisation. COM NO NC Relay Connections when Transmitter NOT Operating COM NO NC Relay Connections when Transmitter OPERATING

DS119-5 June ‘06 ©2006 REG No 277 4001, ENGLAND. Page 4 119, 129 ‘110’ & ‘120’ Transmitter Keyfob Battery Type GP23AE (supplied) Electrical Characteristics Min Typical Max Units Supply Voltage 8.5 9 16 V Supply Current : Quiescent 0 mA Supply Current : Transmitting 8 mA Operating frequency 433.92 MHz ‘102’ Transmitter Encoder Battery Type PP3 (supplied) Dimensions 110mm x 65mm x 24mm Electrical Characteristics Min Typical Max Units Supply Voltage 8 9 12 V Supply Current 11 14 21 mA Frequency: Wideband Narrowband 432.90 434.450 433.92 434.525 434.10 434.575 MHz MHz RF Output Power (ERP) @ 433 MHz - 10 mW ‘009’ Receiver Decoder Dimensions 110mm (not including antenna) x 85mm x 35mm Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55 o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage 230 VAC Supply Current : Quiescent all relays operating 260 mA Relay Rating at 230Vac* 5 12 A Time delay from Tx on Switch to Rx Relay operation 100 mS Time delay from Tx sw relax to Rx Relay release 300 MS *The relay contacts in this unit are for functional use only and must not be used for isolation purposes RS232 Serial Data Output The ‘009’ receiver decoder board can have the capability of an RS232 serial data output via Connector J6. This requires the addition of an RS232 driver chip (MAX232) in position U5 and associated capacitors C5,6,7,8 (100nF). The data output connections from the PCB should be made to Pin 2 and the ground connection made to Pin 5 of a 9 way ‘D’ type connector. The COM port settings should be:- Bits per Second: 9600 Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None The data stream contains the encoder serial number, button code and low battery status bit. For more information on using the serial data output or for general enquiries, please call: RF Solutions Ltd. Unit 21, Cliffe Industrial Estate, Lewes, E. Sussex, BN8 6JL, England Tel +44 (0)1273 898 000 Fax +44 (0)1273 480 661 Information contained in this document is believed to be accurate , however no representation or warranty is given and no liabi lity is assumed by R.F. Solutions Ltd. with respect to the accuracy of

DS119-5 June ‘06 ©2006 REG No 277 4001, ENGLAND. Page 5 119, 129