All data sheets are subject to change without notice (858) 503-3300 - Fax: (858) 503-3301 - www.maxwell.com Low-Power Quad Operational Amplifier ©2002 Maxwell Technologies All rights reserved. 124

04.02.02 Rev 5

FEATURES:

  • R AD-PAK® technology-hardened against natural space radi- ation
  • Total dose hardness: - > 100 krad (Si), depending upon space mission
  • Excellent Single Event Effects:
  • - SELTH LET = > 90 MeV/mg/cm2
  • Package: -14 pin Rad-Pak® flat pack
  • Internally frequency compensated for unity gain
  • Large DC voltage gain
  • Wide bandwidth (unity gain): 1 MHz
  • Large output voltage swing 0V to V+ -1.5V
  • Input common - mode voltage range includes ground
  • Wide power supply range: - Single supply 3V to 32V - Dual supply ±1.5V to ±16V
  • Very low current drain (essentially independent of supply voltage): 700 uA
  • Low input biasing current: 45 nA
  • Low input offset voltage and current: 2mV, 5nA
  • Differential input voltage r ange equal to the power supply voltage DESCRIPTION: Maxwell Technologies’s 124 independent, high gain, internally frequency compensated operational amplifiers feature a greater than 100 krad (Si) total dose tolerance, depending upon space mission. Using Maxwell’s radiation-hardened Rad-Pak® packaging technology, the 124 is designed specifi- cally to operate from a single power supply over a wide range of voltages. The 124 also features operation from split power supplies, and the low power s upply current drain is indepen- dent of the magnitude of the power supply voltage. Maxwell Technologies' patented R AD-PAK® packaging technol- ogy incorporates radiation shie lding in the microcircuit pack- age. It eliminates the need for box shielding while providing the required radiation shielding fo r a lifetime in orbit or space mission. In a GEO orbit, R AD-PAK provides greater than 100 krad (Si) radiation dose toleranc e. This product is available with screening up to Class S. Logic Diagram

TABLE 1. PINOUT DESCRIPTION

4 V+ Power Supply

11 GND Ground

TABLE 2. 124 ABSOLUTE MAXIMUM RATINGS

  1. This input current will only exist when the voltage at any of the input leads is driven negative. It is due to the collector-base

again returns to a value greater than -0.3V (at 25°C).

  1. Short circuits from the output to V+ can cause excessive heating and eventual destruction. When considering short circuits to

in excess of +15V, continuous short-circuits can exceed the power dissipation ratings and cause eventual destruction. Destructive dissipation can result from simultaneous shorts on all amplifiers.

  1. Human body model, 1.5 k Ω in series with 100 pF.

TABLE 3. DELTA LIMITS

TABLE 4. 124 ELECTRICAL CHARACTERISTICS

  1. Due to proximity of external components, insure that coup ling is not originating via stray capacitance between these external parts. This typically can

be detected as this type of capacitance increases at higher frequencies.

  1. Short circuits from the output to V+ can cause excessive heat ing and eventual destruction. When considering short circuits to ground, the maximum
  2. VO@1.4V, RS=0 Ω with V+ from 5V to 30V; and over the full input common-mode range (0V to V+ -1.5V).
  3. The input common-mode voltage of either input signal voltage should not be allowed to go negative by more than 0.3V (at 25°C) . The upper end of

FIGURE 1. INPUT VOLTAGE RANGE FIGURE 2. INPUT CURRENT

FIGURE 3. SUPPLY CURRENT FIGURE 4. VOLTAGE GAIN

FIGURE 5. OPEN LOOP FREQUENCY RESPONSE FIGURE 6. COMMON MODE REJECTION RATIO

FIGURE 7. VOLTAGE FOLLOWER PULSE RESPONSE FIGURE 8. VOLTAGE FOLLOWER PULSE RESPONSE (SMALL SIGNAL)

FIGURE 9. LARGE SIGNAL FREQUENCY RESPONSE FIGURE 10. OUTPUT CHARACTERISTICS CURRENT SOURCING

FIGURE 11. OUTPUT CHARACTERISTICS CURRENT SINKING FIGURE 12. CURRENT LIMITING

10All data sheets are subject to change without notice ©2002 Maxwell Technologies All rights reserved. Low-Power Quad Operational Amplifier Note: All dimensions in inches. 14-PIN RAK-PAK® FLAT PACKAGE SYMBOL DIMENSION MIN NOM MAX A 0.119 0.132 0.145 b 0.010 0.017 0.022 c 0.004 0.005 0.009 D 0.250 0.255 0.260 E 0.250 0.255 0.260 E1 -- -- 0.290 E2 0.125 0.135 -- E3 0.030 0.060 -- e 0.050 BSC L 0.338 0.348 0.358 Q 0.021 0.025 0.030 S1 0.005 0.019 -- N1 4

11All data sheets are subject to change without notice ©2002 Maxwell Technologies All rights reserved. Low-Power Quad Operational Amplifier Important Notice: These data sheets are created using the chip manufacturer’s published specifications. Maxwell Technologies verifies functionality by testing key parameters either by 100% testing, sample testing or characterization. The specifications presented within these data sheets represent the latest and most accurate information available to date. However, these specifications are subject to change without notice and Maxwell Technologies assumes no responsibility for the use of this information. Maxwell Technologies’ products are not authorized for use as critical components in li fe support devices or systems without express written approval from Maxwell Technologies. Any claim against Maxwell Technologies must be made within 90 days from the date of shipment from Maxwell Tech- nologies. Maxwell Technologies’ liability shall be limited to replacement of defective parts.

12All data sheets are subject to change without notice ©2002 Maxwell Technologies All rights reserved. Low-Power Quad Operational Amplifier Feature Option Details124 RP F X Screening Flow Package Radiation Feature Base Product Nomenclature Monolithic S = Maxwell Class S B = Maxwell Class B E = Engineering (testing @ +25°C I = Industrial (testing @ -55°C, +25°C, +125°C) F = Flat Pack RP = R AD-PAK® package Low-Power Quad Operational Amplifier