AES1135 SCHMERSAL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
20.04.2011 17:44:58h Print Create PDF Create EXCEL file Datasheet AES 1135 Guard door monitors and Safety control modules for Emergency Stop
applications
(Minor differences between the printed image and the original product may exist!) Monitoring of BNS range magnetic safety sensors safety contact, STOP Signalling outputs Ordering details Product type
description
13849-1, IEC 61508 PL up d Control category up PFH value 1.0 x SIL up Mission time Years Global Properties Product name AES 113x
60204-1, IEC 60947-5-3, EN 954-1, BG-GS-ET-14, BG-GS-ET-20 Compliance with the Directives (Y/N) Yes Climatic stress EN 60068-2-3, BG-GS-ET-14 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated Material of the contacts Ag-Ni, 0,2 µm gold flashed Weight 155 g Start conditions Automatic Start input (Y/N) No Feedback circuit (Y/N) No Start-up test (Y/N) No Reset after disconnection of supply voltage (Y/N) Yes Automatic reset function (Y/N) Yes Reset with edge detection (Y/N) No Pull-in delay ON delay with automatic start adjustable 0,1 1.0 s Drop-out delay Drop-out delay in case of emergency stop ms Mechanical data Connection type Screw connection Cable section Min. Cable section 0,25 mm² Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) No Mechanical life 20.000.000 operations Electrical lifetime 150.000 operations for 230 VAC, A (cos φ restistance to shock g ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, Ambient conditions Ambient temperature Min. environmental temperature 0°C Max. environmental temperature 55°C Storage and transport temperature Min. Storage and transport temperature 25°C Max. Storage and transport temperature 70°C Protection class Protection class-Enclosure IP40 Protection class-Terminals IP20 Protection class-Clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 Rated impulse withstand voltage U imp 4.8 kV Overvoltage category III To VDE 0110 Degree of pollution To VDE 0110 Electromagnetic compatibility (EMC)
Min. rated DC voltage for controls 20.4 V Max. rated DC voltage for controls 27.6 V Rated AC voltage for controls, Hz Min. rated AC voltage for controls, Hz Max. rated AC voltage for controls, Hz Rated AC voltage for controls, Hz Min. rated AC voltage for controls, Hz Max. rated AC voltage for controls, Hz Contact resistance max. 100 mΩ Power consumption W Type of actuation DC Switch frequency Hz Rated insulation voltage U i 250 V Rated operating voltage U e VDC ±15% Thermal test current I the A Operating current I e 0,2 A Electronic protection (Y/N) No Inputs Monitored inputs Short-circuit recognition (Y/N) optional Wire breakage detection (Y/N) Yes Earth connection detection (Y/N) Yes Number of shutters adjustable piece piece Number of openers adjustable piece piece Input resistance approx. 4000 Ω at GND Input signal "1" ... VDC Input signal "0" ... VDC Cable length 1000 m with 0,75 mm² (for Rated voltage) Outputs Stop category Number of safety contacts piece Number of auxiliary contacts piece Number of signalling outputs piece Switching capacity Switching capacity of the safety contacts min. mA, max. A Switching capacity of the signaling/diagnostic outputs Y1-Y2 100 mA Fuse rating Protection of the safety contacts A gG D-fuse Fuse rating for the signaling/diagnostic outputs short-circuit proof Signalling output Y1: Authorized operation, safety contacts on; Y2: No authorised operation, safety contacts off Utilisation category To EN 60947-5-1 AC-15: 230 V A DC-13: V A Number of undelayed semi-conductor outputs with signaling function piece Number of undelayed outputs with signaling function (with
contact) piece Number of delayed semi-conductor outputs with signaling function. piece Number of delayed outputs with signalling function (with contact). piece Number of secure undelayed semi-conductor outputs with signaling function piece Number of secure, undelayed outputs with signaling function, with contact. piece Number of secure, delayed semi-conductor outputs with signaling function piece Number of secure, delayed outputs with signaling function (with contact). piece LED switching conditions display LED switching conditions display (Y/N) Yes Number of LED´s piece Integral system diagnosis ISD Integral system diagnosis ISD The following faults are registered by the safety monitoring modules and indicated by ISD Failure of door contacts to open or close Cross-wire or short-circuit monitoring of the switch connections Interruption of the switch connections Failure of the safety relay to pull-in or drop-out Fault on the input circuits or the relay control circuits of the safety monitoring module Miscellaneous data 22.5 mm Height 100 mm Depth 121 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice Wiring example To secure a guard door up to PL and Category #03# Monitoring guard door(s), each with a magnetic safety sensor of the BNS range If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category to EN 954-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. Modification for NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals and X1. The short-circuit recognition
inoperative. Expansion of enable delay time: The enable delay time can be increased from 0,1 s to 1,0 s by changing the position of a jumper link connection under the cover of the unit. The wiring diagram is shown with guard doors closed and in de-energised condition. The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. Documents Operating instructions and Declaration of conformity (de) 824 kB, 30.11.2010 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/DE/mrl_aes1135_1136_de.pdf Operating instructions and Declaration of conformity (fr) 673 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/FR/mrl_aes1135_1136_fr.pdf Operating instructions and Declaration of conformity (it) 660 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/IT/mrl_aes1135_1136_it.pdf Operating instructions and Declaration of conformity (es) 659 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/ES/mrl_aes1135_1136_es.pdf Operating instructions and Declaration of conformity (de) 666 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/DE/mrl_aes1135_1136_de.pdf Operating instructions and Declaration of conformity (nl) 658 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/NL/mrl_aes1135_1136_nl.pdf Operating instructions and Declaration of conformity (jp) MB, 30.11.2010 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/JP/mrl_aes1135_1136_jp.pdf Operating instructions and Declaration of conformity (en) 747 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/EN/mrl_aes1135_1136_en.pdf Wiring example (99) kB, 22.08.2008 http://127.0.0.1/Bilddata/Si_baust/Aes1135/Schaltun/Maes1l01.pdf Wiring example (99) kB, 22.08.2008 http://127.0.0.1/Bilddata/Si_baust/Aes1135/Schaltun/Maes1l02.pdf ISD tables (Intergral System Diagnostics) (en) kB, 29.07.2008 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/ISD/i_ae2p02.pdf ISD tables (Intergral System Diagnostics) (de) kB, 29.07.2008 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/ISD/i_ae2p01.pdf Images
(basic component) Wiring example Wiring example K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted.
20.04.2011 17:44:59h Kasbase 1.4.7 DBI