https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 1 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Flush-type connector, Power, 4-position, Socket, M12, S power, Rear mounting, M16 x 1.5, Individual wires, cable length: 1 m, 1.31 mm², UL/cUL stranded hook-up wire Your advantages For compact devices: transmit high power in a confined space Easy-to-install, optimized XL housing contour with wrench size 19 Mechanical tightening limitation for long-term-stable gasket Pre-assembled with litz wires for immediate use Customer-specific assemblies and litz wire lengths available Sealed on the litz wire side for optimum leak-tightness For high transmission safety: shield connection to the housing with optional EMC nut Key Commercial Data Packing unit 1 pc Minimum order quantity 50 pc GTIN GTIN 4063151171179 Technical data Dimensions Length of cable 1 m Ambient conditions Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket) -25 °C ... 85 °C (Plug / socket) Degree of protection IP67 General Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 2 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Technical data General there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Rated current at 40°C 12 A Rated voltage 630 V Rated surge voltage 6 kV Number of positions 4 Insulation resistance ≥ 100 MΩ Coding S power Standards/regulations M12 connector IEC 61076-2-111 In line with Signal type/category Power Status display No Overvoltage category III Degree of pollution 3 Test voltage 6 kV Connection method Individual wires Insertion/withdrawal cycles > 100 Mounting type Rear mounting M16 x 1.5 With flat nut Assembly instructions Tightening limitation Thread type M16 x 1.5 Halogen-free yes Flame resistance in acc. to UL 1581 VW1 Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Au Contact carrier material PA Material, knurls Zinc die-cast, nickel-plated Sealing material FKM Additional material specifications PU 2K (Grout material) Cable Cable type UL/cUL stranded hook-up wire Conductor cross section 1.31 mm² AWG signal line 16 Core diameter including insulation 2.2 mm Wire colors Black 1, black 2, black 3, green/yellow Material conductor insulation mPPE Conductor material Bare Cu litz wires Standards/specifications M12 connector IEC 61076-2-111 In line with Ambient temperature (operation) -40 °C ... 105 °C (cable, fixed installation)

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 3 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Technical data Cable -20 °C ... 105 °C (cable, flexible installation) Standards and Regulations Standards/specifications M12 connector IEC 61076-2-111 In line with Flame resistance in acc. to UL 1581 VW1 Halogen-free yes Flammability rating according to UL 94 V0 Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.

  • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
  • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
  • The products are suitable for applications in plant, controller, and electrical device engineering.
  • When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
  • Assembled products may not be manipulated or improperly opened.
  • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
  • When using the product in direct connection with third-party manufacturers, the user is responsible.
  • For operating voltages > 50 V AC, conductive connector housings must be grounded
  • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
  • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product
  • Only use tools recommended by Phoenix Contact
  • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
  • Ensure that the protective or functional ground has been properly connected. applicable when combining several circuits in a cable and/or connector
  • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 4 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Technical data Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Schematic diagram Pin assignment of M12 socket, 4-pos., S-coded, socket side view

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 5 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Dimensional drawing M12 flush-type socket

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 6 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Circuit diagram Contact assignment of the M12 socket Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 11.0 27440102 eCl@ss 8.0 27440103 eCl@ss 9.0 27440102 ETIM ETIM 5.0 EC002061 Approvals Approvals Approvals EAC / cULus Recognized Ex Approvals Approval details EAC B.01687

https://www.phoenixcontact.com/pi/products/1162635 10/28/2020 Page 7 / 7 Flush-type connector - SACC-DSI-M12FSS-4P-M16XL/1,0PE - 1162635 Approvals cULus Recognized Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8

32825 Blomberg

Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com