1139034 PHOENIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

https://www.phoenixcontact.com/us/products/1139034 09/27/2021 Page 1 / 5 AC charging controller - CHARX SEC-1000 - 1139034 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) CHARX control modular, AC charging controller according to IEC 61851-1. Configurable charging controller. operating mode Stand-alone or client. interface: CHARX control modular system bus. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting Key Commercial Data Packing unit 1 pc GTIN GTIN 4063151080198 Custom tariff number 85371091 Country of origin Germany Technical data Product definition Type Configurable charging controller Standards/regulations IEC 61851-1 Charging standard IEC 61851-1 Charging mode Mode 3, Case B + C Conformance CE-compliant Dimensions Height 121 mm Width 18.8 mm Depth 85.00 mm Ambient conditions Ambient temperature (operation) -25 °C ... 65 °C

https://www.phoenixcontact.com/us/products/1139034 09/27/2021 Page 2 / 5 AC charging controller - CHARX SEC-1000 - 1139034 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 80 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level) Air pressure (storage/transport) 58 kPa ... 106 kPa (up to 4500 m above mean sea level) Degree of protection IP20 Degree of pollution 2 in acc. with IEC 60664-1 Overvoltage category III Shock (operation) Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Test specification 15g, 11 ms period, half-sine shock pulse Vibration (operation) Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 Test specification 5g, 10...150 Hz, 2.5 h, in XYZ direction Device supply Supply voltage 12 V DC Max. current consumption 2 A (Stand-alone operation) No-load current < 50 mA (without external loads) Data interfaces Interface Energy meters Bus system RS-485 energy meter) Interface RFID readers Bus system RS-485 RFID reader) Interface CHARX control modular system bus Number 1 Connection method DIN rail bus connectors Function interfaces Interface Vehicle interface Communication protocol IEC 61851-1 GB/T 18487 Proximity IEC 61851-1 GB/T 18487 Charging cases Mode 3, Case B + C Control voltage ± 12 V (Locking actuator)

https://www.phoenixcontact.com/us/products/1139034 09/27/2021 Page 3 / 5 AC charging controller - CHARX SEC-1000 - 1139034 Technical data Function interfaces Rated current 2 A Locking release in the event of mains failure Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet Interface Residual current detection Sensor supply voltage 12 V DC Error state signal level 12 V (Different terminal points)

0 V (Different terminal points)

Test & Reset signal level 12 V Interface Temperature monitoring Sensor type Pt 1000 PTC chain Tripping characteristic configurable Interface Contactor control Interface description Floating switch contact Switching voltage max. 250 V AC max. 30 V DC Rated current 2 A Interrupting rating max. 1500 VA Inputs Description of the input Digital input Number inputs 4 Nominal input voltage UN 12 V Input voltage range 0 V ... 3 V (Off) 9 V ... 15 V (On) Function configurable Outputs Output name Digital output Number outputs 4 Operating mode High-Side (Output switched to internal 12 V voltage) Low-Side (Output switched to GND potential) Output voltage 12 V (High-side operation) ≤ 12 V (Low-side operation) Output current max. 600 mA Function configurable Connection data Connection technology pluggable

https://www.phoenixcontact.com/us/products/1139034 09/27/2021 Page 4 / 5 AC charging controller - CHARX SEC-1000 - 1139034 Technical data Connection data Push-in technology Conductor cross section AWG 24 ... 16 Stripping length 8 mm 10 mm (for contactor control) Classifications eCl@ss eCl@ss 11.0 27144703 eCl@ss 9.0 27144703 ETIM ETIM 7.0 EC002889 Accessories Accessories Residual current monitoring module Differential current monitoring - EV-RCM-6DC-WAT - 1309697 The residual current monitoring module is used for AC and DC residual current detection in AC charging points. The higher-level safety equipment (e.g., residual current device) is protected against potential DC residual currents. Differential current monitoring - EV-RCM-6DC-WAT-X10 - 1309695 The residual current monitoring module is used for AC and DC residual current detection in AC charging points. The higher-level safety equipment (e.g., residual current device) is protected against potential DC residual currents. RFID device

https://www.phoenixcontact.com/us/products/1139034 09/27/2021 Page 5 / 5 AC charging controller - CHARX SEC-1000 - 1139034 Accessories RFID device - EV-RFID-ELT-PCB - 1309772 RFID card reader for connection to CHARX control modular charging controllers RFID device - EV-RFID-ELT-PCB-X10 - 1309752 RFID card reader for connection to CHARX control modular charging controllers RFID device - EV-RFID-ELT-IP65 - 1309687 RFID card reader for connection to CHARX control modular charging controllers Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com