https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 1 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Configurable safety module (basic module), 8 safe inputs, 2 safe outputs, 2 reset inputs, 2 signal outputs, 4 clock outputs, can be extended via TBUS, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector not included Product Description The configurable and individually scalable PSRmodular safety system is a flexible safety solution for monitoring your machine or system. The freely configurable base module is used to monitor various pieces of safety equipment such as emergency stop, safety doors, and light grids. The base module has safe inputs and outputs, as well as signal outputs and clock outputs. Your advantages Economical safety solution with a high level of adaptability to individual requirements Fast startup, thanks to easy hardware and software configuration Machine downtime minimized with comprehensive, easy-to-understand diagnostics Flexible extension with safe inputs and outputs Possibility of connecting fieldbus gateways for bidirectional communication between the base module and the higher-level controller Tool-free and time-saving installation with Push-in technology Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508 Suitable for lift applications according to EN 81-20 Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626967592 Weight per Piece (excluding packing) 200.000 g Custom tariff number 85371098 Country of origin Italy

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 2 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Technical data Dimensions Width 22.61 mm Height 107.74 mm Depth 113.6 mm Ambient conditions Ambient temperature (operation) -10 °C ... 55 °C (observe derating) Ambient temperature (storage/transport) -20 °C ... 85 °C Max. permissible relative humidity (operation) 95 % (non-condensing) Max. permissible humidity (storage/transport) 95 % (non-condensing) Maximum altitude ≤ 2000 m (Above sea level) Power supply Designation A1/A2 Rated control circuit supply voltage US 24 V DC -20 % / +20 % (external fuse, typically 4 A) Rated control supply current IS typ. 55 mA (Outputs inactive) typ. 70 mA (Outputs active, without load) Current consumption max. 4 A (with full load) Power consumption at US typ. 1.32 W (Outputs inactive) Inrush current 9.5 A (Δt = 1 ms at Us) Filter time typ. 5 ms (at A1 in the event of voltage dips at Us) Protective circuit Inverse-parallel protection against polarity reversal Suppressor diode Digital inputs Input name IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8 Description of the input Safety-related digital inputs EN 61131-2 type 1 Number of inputs 8 Input voltage range "0" signal 0 V DC ... 5 V DC Input voltage range "1" signal 15 V DC ... 28.8 V DC Input current range "0" signal < 1 mA Current consumption typ. 8 mA (typically with US) max. 10 mA (at a control voltage of 28.8 V DC) Filter time min. 3 ms ±2 ms (adjustable) max. 250 ms ±2 ms (adjustable) Test pulse rate ≥ 2x set filter time, min. Test pulse rate = 10 ms Max. permissible overall conductor resistance max. 1.2 kΩ (Input and reset circuit at US) Cable length max. 100 m (per input)

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 3 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Technical data Digital inputs Protective circuit/component Suppressor diode Input name Reset inputs FBK1, FBK2 Description of the input IEC 61131-2 type 3 non-safety-related (configurable) Number of inputs 2 Input voltage range "0" signal 0 V DC ... 5 V DC Input voltage range "1" signal 11 V DC ... 28.8 V DC Input current range "0" signal < 1 mA Current consumption typ. 10 mA (typically with US) max. 13 mA (at a control voltage of 28.8 V DC) Filter time 250 ms ±2 ms (Test pulse rate > 500 ms) Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US) Cable length max. 100 m (per input) Protective circuit/component Suppressor diode Input name Enable inputs EN1, EN2 Number of inputs 2 Input voltage range "0" signal 0 V DC ... 5 V DC Input voltage range "1" signal 8 V DC ... 28.8 V DC Current consumption typ. 0.7 mA (typically with US) max. 1 mA (at a control voltage of 28.8 V DC) Protective circuit/component Suppressor diode Digital outputs Output name O1A, O1B, O2A, O2B Output description Safety-related digital outputs PNP, OSSD IEC 61131-2 type 0.5 (observe limiting continuous current) Number of outputs 4 (can be used as 2 two-channel outputs) Nominal output voltage 24 V DC (Supply via A1) Limiting continuous current 400 mA (per channel)

1.6 A (Total current of all safe digital outputs)

Inrush current max. 750 mA (Δt  1 s) Output voltage when switched off < 1.5 V Leakage current max. 500 µA

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 4 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Technical data Digital outputs Cable length max. 100 m (per output) Ohmic load min. 50 Ω (Observe limiting continuous current) Max. capacitive load max. 680 nF Max. inductive load max. 1.4 mH Switching frequency max. 1/4 x tCycle [Hz] Test pulses < 80 µs (Test pulse width of low test pulses) Test pulse rate for low test pulses > 2 x TCycle < 20 µs (Test pulse width, high test pulse) ≥ 1.5 s (Test pulse rate, high test pulse) Protective circuit/component Suppressor diode Short-circuit protection Yes (self-limitation at 1.1 A) Error detection time at 1-channel structure < 3.5 s (OFF state) < 4 x tCycle [ms] (ON state) Discharging circuit Yes, internal Alarm outputs Designation MO1, MO2 Output description PNP, IEC 61131-2 Typ 0,1 non-safety-related Number of outputs 2 Voltage 24 V DC (via A1) Output voltage when switched off max. 0.1 V Maximum inrush current 1.1 A (Δt = 3 s at Us) Switching frequency max. 1/4 x tCycle [Hz] Limiting continuous current 100 mA (per channel) 200 mA (Total current of all digital signal outputs) Leakage current max. 100 µA Protective circuit/component Suppressor diode Short-circuit protection Yes (self-limitation at 1.1 A) Cable length max. 100 m (per output) Clock outputs Designation T1, T2, T3, T4 Output description PNP, IEC 61131-2 type 0.5 Number of outputs 4 Voltage 24 V DC (via A1)

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 5 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Technical data Clock outputs Output voltage when switched off max. 0.1 V Maximum inrush current 1.1 A (Δt = 3 s at Us) Limiting continuous current 100 mA (per channel) 400 mA (Total current of all outputs) Leakage current max. 100 µA Cable length max. 100 m (per output) Max. capacitive load max. 470 nF Max. inductive load max. 2.4 mH Test pulses ≤ 220 µs (Test pulse duration) Test pulse rate = 8 x tCycle [ms] Protective circuit/component Suppressor diode Short-circuit protection Yes (self-limitation at 1.1 A) Discharging circuit Yes, internal Times Response time see user manual Restart time min. 5 s (Boot time) max. 10 s (Boot time) Cycle time see user manual General Nominal operating mode 100% operating factor Net weight 141 g Mounting position vertical or horizontal Mounting type DIN rail mounting Assembly instructions Observe derating Degree of protection IP20 Min. degree of protection of inst. location IP54 Protection class III (EN 50178) Housing material Polyamide PA non-reinforced Housing color yellow Operating voltage display 1 x green LED Status display 1 x LED (green), 1 x LED (orange), 1 x LED (blue) 2 x LED (green, red) 12 x LED (yellow) Indication 2 x LED (red) Connection data Connection method Push-in connection

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 6 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Technical data Connection data pluggable Yes Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 10 mm Safety-related characteristic data Stop category 0 Designation IEC 61508 - High-demand for 2-channel wiring Safety Integrity Level (SIL) 3 Designation IEC 61508 - High-demand for 1-channel wiring Safety Integrity Level (SIL) 2 Designation EN ISO 13849 Performance level (PL) e (2-channel wiring) d (1-channel wiring) Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring) 2 (1-channel wiring) Standards and Regulations Designation Air clearances and creepage distances between the power circuits Standards/regulations EN 50178 Rated insulation voltage 250 V AC Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing Degree of pollution 2 Overvoltage category II Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction) Vibration (operation) 10 Hz ... 150 Hz, 2g Conformance CE-compliant Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 7 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Application drawing Block diagram Classifications eCl@ss eCl@ss 10.0.1 27371819 eCl@ss 8.0 27371819 eCl@ss 9.0 27371819 ETIM ETIM 5.0 EC001449 Approvals Approvals

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 8 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cULus Listed Accessories Accessories Coding element Coding profile - CP-MSTB - 1734634 Coding profile, is inserted into the slot on the plug or inverted header, red insulating material Coding section - CR-MSTB - 1734401 Coding section, inserted into the recess in the header or the inverted plug, red insulating material

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 9 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Accessories Configuration memory Configuration memory - PSR-M-MEMORY - 1105142 Optional memory block for the PSRmodular system for easy storage and backup of configuration data DIN rail connector DIN rail bus connectors - ME 22,5 TBUS 1,5/ 5-ST-3,81 YE - 2200244 DIN rail connector, nominal current: 8 A, rated voltage (III/2): 125 V, number of positions: 5, pitch: 3.81 mm, color: yellow, mounting: DIN rail, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts DIN rail bus connectors - ME 22,5 TBUS 1,5/ 5-ST-3,81 YE - 1PCS - 1225375 DIN rail connector, number of positions: 5, pitch: 3.81 mm, color: yellow Filter terminal block Filter terminal block - PSR-FTB/1.5/11.5 - 2904476 Terminal block for filtering test pulses from safe semiconductor outputs with adjustable filter values (1.5 µF/11.5 µF), as well as for EMC filtering of 24 V signals up to an amperage of 2 A.

https://www.phoenixcontact.com/us/products/1104972 09/25/2020 Page 10 / 10 Safety module - PSR-M-B1-SDI8-SDO2-DO2-PI - 1104972 Accessories Filter terminal block - PSR-FTB/20/86 - 2904477 Terminal block for filtering test pulses from safe semiconductor outputs with adjustable filter values (20 µF/86 µF), as well as for EMC filtering of 24 V signals up to an amperage of 2 A. Programming cable USB cable - CABLE-USB/MINI-USB-3,0M - 2986135 USB connecting cable: USB plug type A to USB plug type Mini-B; length: 3 m Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com