Features
- Measure and simulate 8 thermocouples
- Measure and simulate Pt100-RTD
- Measure and source μV/mV/mA
- Displays units in °C, °F , μV/mV , or mA
- Automatic or manual cold junction compensation
- 10 point memory recall
- Process loops 4 to 20 mA and 0 to 50 mA
- 24 V loop drive voltage
- Mains or battery operation
- 60 hours typical use between charges Memory recall and step/auto-step functions Up to 10 values can be stored in the unit’s non- volatile memory and they can be recalled at any time. The user can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also available at any user selectable rate between 1 and 10 seconds/step. Power is via an internal high capacity rechargeable metal hydride battery that can be recharged from an external mains charger (supplied as standard). An auto power-down feature helps conserve battery lifeby switching off the instrument if inactive for over 5 minutes. This can be disabled if not required. The unit is supplied in a robust case with a carrying strap. A pocket for the instruction manual is provided.
1090 Portable Process Calibrator
Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2b Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Temperature Measure accuracy Simulate accuracy Thermocouple type Temp range °C Accuracy °C Thermocouple type Temp range °C Accuracy °C J –200 to 580 0.7 J –210 to 150 0.15 150 to 1200 0.3 K –200 to -150 2.5 K –270 to 190 0.5 –150 to 750 0.5 190 to 1250 0.4 T –200 to 0 1.5 T –200 to 150 0.4 0 to 400 0.4 150 to 400 0.5 R 50 to 400 3.0 R –50 to 800 0.8 400 to 1750 1.5 800 to 1750 2.0 S –50 to 100 3.0 S –50 to 850 0.9 100 to 1750 1.5 850 to 1750 2.0 B 110 to 1000 3.5 B 100 to 1200 2.0 1000 to 1800 1.5 1200 to 1800 3.0 N –100 to 890 0.6 N –270 to 260 0.5 260 to 1300 1.0 E –50 to 400 0.4 E –50 to 1000 0.3 Resolution: 0.1 °C or °F Resolution: 0.1 °C or °F An additional correction representing the equivalent 1 μV should be allowed for stray thermal emf effects. PT100 Pt100 measure Pt100 simulation Range Accuracy Resolution Set temperature points (°C) Accuracy –200 to 700 °C, 2 wire. 0.2 % of resistance value 300, 400, 500, 600, 700, 800 0.1 % of resistance value (typically 0.5 °C) Voltage Millivolt measure Millivolt source Range Resolution Accuracy Input resistance Range Resolution Accuracy Output resistance 0 to 30 mV 10 μV 0.05 % FS ± 1 digit 100 kΩ 0 to 8 mV 0.5 μV ± 4 μV 10 Ω 8 to 80 mV 5 μV 0.02 % FS 10 Ω Current Milliamp measure Milliamp source Range Resolution Accuracy Input resistance Range Resolution Accuracy Max load (24 V drive) 0 to 60 mA 20 μA 0.05 % FS ± 1 digit 0.5 Ω 0 to 8 mA 0.5 μA ± 10 μA 300 Ω / 80 mA 480 Ω / 50 mA 1.2 kΩ / 20 mA8 to 80 mA 5 μA 0.02 % FS General Specifications