1088104 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 10
Technical content
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 1 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline Smart Elements, Analog input module, Analog inputs: 4, 0 V ... 10 V, connection technology: 2- conductor, degree of protection: IP20 Product Description You can integrate Axioline Smart Elements into systems with the Smart Element interface. This Smart Element detects analog voltage signals. Your advantages 4 analog input channels Connection of sensors in 2-conductor technology Voltage range: 0 V ... 10 V Data format: standardized representation Resolution: 12 bits Substitute value behavior can be parameterized for each input Device rating plate stored Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626887715 Weight per Piece (excluding packing) 40.000 g Custom tariff number 85389091 Country of origin Germany Technical data Note
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 2 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Caption Dimensions Width 14.9 mm Height 62.2 mm Depth 62 mm Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation I/O Connection method Push-in connection Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual. Conductor cross section solid min. 0.25 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm General Mounting type Smart Element slot Color traffic grey A RAL 7042 Net weight 35 g Degree of pollution 2 (EN 60664-1) Mounting position See the system in which the Smart Element is used. Interfaces
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 3 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Technical data Interfaces Designation Smart Element interface Number 1 Connection method Card edge connector Transmission speed See system in which you use the Smart Element. Start time until ready to operate < 1000 ms Axioline potentials Designation Communications power supply of the Smart Elements (USE) Additional text using card edge connectors Current consumption max. 22 mA Designation I/O supply (UP) Supply voltage 24 V DC (using card edge connectors) Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption min. 12 mA (without connected peripherals) typ. 15 mA max. 20 mA Power consumption min. 288 mW max. 480 mW Protective circuit Surge protection See the system in which the Smart Element is used. Reverse polarity protection Polarity protection diode Protection See the system in which the Smart Element is used. Analog inputs Description of the input Single-ended inputs, voltage Input name Analog inputs Number of inputs 4 Connection method Push-in technology Connection technology 2-conductor Note regarding the connection technology shielded, twisted pair A/D converter resolution 12 bit Type of protection Transient protection Data formats Standardized representation Measured value representation 16 bits Voltage input signal 0 V ... 10 V Input resistance of voltage input > 100 kΩ Precision typ. 0.1 % (of measuring range end value) Electrical isolation Test section Communications supply / 24 V supply (I/O) 500 V AC 50 Hz 1 min.
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 4 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Technical data Electrical isolation Communications supply / functional ground 500 V AC 50 Hz 1 min. 24 V supply (I/O) / functional ground 500 V AC 50 Hz 1 min. Standards and Regulations Immunity to ESD Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Immunity to EF Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity to burst Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV Immunity to surge Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, shielded I/O cables: ±1 kV asymmetrical Immunity to conducted interference Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Interference emission Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 Class A Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Protection class III (IEC 61140, EN 61140, VDE 0140-1) Overvoltage category II (IEC 60664-1) Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 5 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Connection diagram U U Connection example
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 6 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Block diagram U Data USE UPFE REF µCE FE Internal wiring of the terminal points
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 7 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Dimensional drawing 35,8 55,2 58,7 14,9 5,7 62,2 14,2 Dimensions Classifications eCl@ss eCl@ss 10.0.1 27242601 eCl@ss 11.0 27242601 eCl@ss 9.0 27242601 ETIM ETIM 7.0 EC001596 UNSPSC UNSPSC 18.0 32151602 UNSPSC 19.0 32151602 UNSPSC 20.0 32151602 UNSPSC 21.0 32151602 Approvals Approvals
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 8 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cULus Listed Accessories Accessories Crimping tool Crimping pliers - CRIMPFOX 6 - 1212034 Crimping pliers, for ferrules without insulating collar according to DIN 46228 Part 1 and ferrules with insulating collar Crimping pliers - CRIMPFOX DUO 10 - 1031721 Crimping pliers, type of contact: Insulated and uninsulated ferrules, min. cross section: 0.14 mm², max. cross section: 10 mm², for TWIN ferrules up to 2 x 4 mm², automatic cross section adjustment, rotating die, lateral and frontal insertion, compression: Trapezoidal crimp, black/green
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 9 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Accessories Crimping pliers - CRIMPFOX 10T-F - 1134913 Crimping pliers, type of contact: Insulated and uninsulated ferrules, standards/specifications: DIN 46228-1, DIN 46228-4, min. cross section: 0.14 mm², max. cross section: 10 mm², For TWIN ferrules up to 2 x 4 mm², automatic cross section adjustment, frontal insertion, compression: Trapezoidal crimp, black I/O component Module carrier - AXL F BP SE4 - 1088135 Axioline F, Backplane, 4 slots for Axioline Smart Elements, transmission speed in the local bus: 100 Mbps, degree of protection: IP20 Module carrier - AXL F BP SE6 - 1088136 Axioline F, Backplane, 6 slots for Axioline Smart Elements, transmission speed in the local bus: 100 Mbps, degree of protection: IP20 Screwdriver tools Screwdriver - SZS 0,4X2,5 VDE - 1205037 Screwdriver, slot-headed, VDE insulated, size: 0.4 x 2.5 x 80 mm, 2-component grip, with non-slip grip Terminal marking
https://www.phoenixcontact.com/us/products/1088104 12/24/2021 Page 10 / 10 I/O module - AXL SE AI4 U 0-10 - 1088104 Accessories Label - MM-TML (EX4,2)R C1 TR/BK - 0803979 Label, Roll, transparent, unlabeled, can be labeled with: THERMOFOX, THERMOMARK GO, THERMOMARK GO.K, mounting type: adhesive, for terminal block width: 8000 mm, lettering field size: continuous x 4.2 mm Marker strip - SK 5,0 WH:REEL - 0805221 Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL 2.0, THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, mounting type: adhesive, for terminal block width: 5 mm, lettering field size: continuous x 5 mm, Number of individual labels: 90000 Marker for terminal blocks - UM6M-TM (5X12) - 0830928 Markers for marking terminal blocks from ABB/Entrelec, 24-section, unmarked, can be marked with THERMOMARK CARD and BLUEMARK, color: white Marker for terminal blocks from the SNK series from ABB - UCT6M-TM 5 - 0830756 Marker for terminal blocks from the SNK series from ABB, Sheet, white, unlabeled, can be labeled with: THERMOMARK CARD, THERMOMARK CARD 2.0, THERMOMARK PRIME, BLUEMARK ID, BLUEMARK ID COLOR, TOPMARK LASER, TOPMARK NEO, mounting type: snapped, for terminal block width: 5.2 mm, lettering field size: 4.17 x 11.3 mm Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com