1087079 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 1 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) technology: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20, including bus base module and connectors Product Description The module is an Axioline P I/O module for use in the Axioline P modular I/O system. The module is a modular I/O device that can be affixed to the Axioline P local bus, to communicate I/O data up to the Axioline P bus coupler, which forms the head of the station. The module is fully hot-swappable on the Axioline P local bus, which also provides power to the module. The module allows the connection of up to four HART devices. The analog input I/O module with HART capabilities collects analog input and HART data from the field I/O terminals and makes this information available to the bus coupler through the Axioline P local bus. Your advantages 4 analog output-powered control signals for HART Cyclic access to PV, SV, TV, QV, and Loop Current Temperature range of -40 °C ... +70 °C Hot-swappable Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626882468 Weight per Piece (excluding packing) 360.000 g Custom tariff number 85389091 Country of origin United States
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 2 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Use in potentially explosive areas is not permitted in China. Dimensions Width 53.6 mm Height 126.1 mm Depth 77.14 mm Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -40 °C ... 70 °C (Standard) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 2000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 2000 m above sea level) Maximum altitude 2000 m Degree of protection IP20 IP20 Connection data Designation Axioline P connector Connection method Push-in connection Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual. Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm General Mounting type DIN rail Color traffic grey A RAL 7042 Net weight 353 g Note on weight specifications with connectors and bus base module
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 3 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Technical data General Degree of pollution 2 Mounting position any (no temperature derating) Maximum altitude 2000 m Interfaces Designation Axioline P local bus Connection method Bus base module Transmission speed 100 Mbps Axioline potentials Designation Supply of the logic voltage UL Designation Supply of the Axioline P local bus UBus Supply voltage 5 V DC (via bus base module) Current consumption max. 135 mA Analog outputs Number of outputs 4 (HART) Connection method Push-in connection Connection technology 2-conductor Note regarding the connection technology shielded, twisted pair Output name Analog outputs Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Electrical isolation Test section 5 V supply of the local bus (UBus) / functional ground 500 V AC 62 Hz 1 min. 24 V supply (I/O) / functional ground 500 V AC 62 Hz 1 min. Field to functional earth 500 V AC 62 Hz 1 min. Field to 5 V and 24 V supplies 1500 V AC 62 Hz 1 min. Standards and Regulations Immunity to EF Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity to burst Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Immunity to surge Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 4 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Technical data Standards and Regulations Immunity to conducted interference Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Interference emission Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 Class A Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g ATEX DEMKO 20 ATEX 2334X II 3G Ex ec IIC T4 Gc IECEx IECEx UL 20.0002X Ex ec IIC T4 Gc UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T4 Protection class III (IEC 61140, EN 61140, VDE 0140-1) Overvoltage category II Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Connection diagram 0000
31 Dimensional drawing
53,6 77,1 122,4 126,1 Classifications eCl@ss eCl@ss 10.0.1 27242601 eCl@ss 11.0 27242601
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 5 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Classifications eCl@ss eCl@ss 9.0 27242601 ETIM ETIM 7.0 EC001596 UNSPSC UNSPSC 18.0 32151602 UNSPSC 19.0 32151602 UNSPSC 20.0 32151602 UNSPSC 21.0 32151602 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals ATEX / IECEx / UL Listed / cUL Listed / cULus Listed Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cULus Listed Accessories Accessories
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 6 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Accessories DIN rail connector Bus connector - AXL P BS F2 - 1052428 Axioline P bus base module for housing type F2 Shield connection Shield connection - AXL SHIELD SET - 2700518 Axioline shield connection set (contains 2 shield bus holders and 2 SK 5 shield connection clamps) Terminal marking Zack marker strip - ZB 20,3 AXL UNPRINTED - 0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER Terminal resistor Termination block - AXL P TERM PAIR - 2316402 Axioline P terminator pair Additional products
https://www.phoenixcontact.com/us/products/1087079 12/24/2021 Page 7 / 7 I/O module - AXL P AO4 HART 1F - 1087079 Accessories Termination block - AXL P TERM PAIR - 2316402 Axioline P terminator pair Spare parts Bus connector - AXL P BS F2 - 1052428 Axioline P bus base module for housing type F2 Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com