0131 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 19

Technical content

Visit product website  DATA SHEET Type 1087  Timer, form A according to DIN EN 175301 - 803 Type 2518  Cable plug, form A according to DIN EN 175301-803 Type 1060  Electrical position feedback for pneumat- ically operated process valves Standard | EU | en | 202211 | 11 Direct-acting 2/2-way or 3/2-way toggle valve

  • Dir ect-acting media-separated valve up to DN 20 V ibration-proof, block screwed solenoid system Ener gy-saving power reduction for all DC variants Incr eased safety due to electrical position feedback (optional) Robust, ser vice-friendly manual override The 0131 valve is a direct-acting toggle valve. A variety of seal material combinations are available depending on the application. Thanks to the diaphragm separation between actuator and fluid housing, aggressive media such as acids and alkaline solutions can also be safely controlled. The assort- ment is rounded out with plastic housings made of PVC. The solenoids are moulded with a highly resistant chemical epoxy. “Kick and drop” electronics are moulded into all DC solenoid variants for reduced electrical power con- sumption. An optional electrical position feedback sensor reliably detects the switching position. Conformity with KTW and W270 are available for drinking water applications. Furthermore, versions of type 0131 are available that conform with DIN EN 45545:2016 (standard parts 2 and 5) – fire protection in railway vehicles. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 0131 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 19 Visit product website  Table of contents 1. Gener al technical data 3 1.2. V ersion for railway application 2. Cir cuit functions 5 Materials 3.2. 3/2 way br ass version 3.3. 3/2 way plastic version with union nut and connection fitting 3.4. 2/2 way br ass version 3.5. 2/2 way plastic version with tr ue union nut and connection fitting 3.6. 2/2 way br ass version for railway application 4. Dimensions 8 4.2. 3/2 way plastic version with union nut and connection fitting 4.3. 2/2 way br ass version for standard and railway application 4.4. 2/2 way plastic version with tr ue union nut and connection fitting 5. Device/P rocess connections 12 6. Or dering information 12 6.2. Bürk ert product filter 6.3. Or dering chart 3/2 way version, seal material EPDM 3/2 way version, seal material NBR 3/2 way version, seal material FKM 2/2 way version, seal material EPDM 2/2 way version, seal material FKM 2/2 way brass version for railway application 6.4. Or dering chart accessories Cable plug Type 2518, form A according to DIN EN 175301 - 803 Timer Type 1087, form A according to DIN EN 175301 - 803

3 | 19 Visit product website  1. Gener al technical data 1.1. S tandard version Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 8. Material Seal NBR, EPDM, FKM Body PVC, brass Nominal diameter DN 10…DN 20 Circuit function Detailed information can be found in chapter “2. Circuit functions” on page 5. Performance data Duty cycle ED 100 Switching frequency 60/min with AC Max. 6/min with UC Switching time1.) Open: 10…20 ms Close: 40…60 ms Electrical data Operating voltage 024/UC, 230/UC, 024/50, 230/50 Power consumption Inrush AC: 100…120 VA UC: 100 W Hold AC: 48 VA/16 W UC: 9 W Voltage tolerance ± Medium data Operating medium Aggressive and non-aggressive fluids, neutral gases, aggressive gases according to their diffusion properties Medium temperature (Body + Seal) PVC / EPDM PVC / FKM Brass / EPDM Brass / FKM Brass / NBR °C…+ °C…+ °C…+ 130°C2.) - 10 °C…+ 130°C2.) - 10 °C…+ 90 °C V iscosity (max.) 37 mm2/s Process/Port connection & communication Electrical connection Cable plug Type 2518 according to DIN EN 175 301 803, form A (included in deliver y), see “Cable plug Type 2518, form A according to DIN EN 175301 - 803” on page Approvals and certificates Degree of protection IP65 with cable plug Environment and installation Installation position Any, preferably actuator face up Ambient temperature Max. + 1.) Measurement at the valve outlet 6 bar and 20 °C. Opening: P ressure build-up 0…90 %, Closing: P ressure reduction 100…10 % 2.) Max. medium t emperature for versions with high-performance electronics (encoding .../UC) is 90 °C.

4 | 19 Visit product website  1.2. V ersion for railway application Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 8. Material Seal EPDM Body Brass Nominal diameter DN 10…DN 20 Circuit function A and B Detailed information can be found in chapter “2. Circuit functions” on page 5. Thermal insulation class of solenoid coil H Performance data Duty cycle 100 % duty cycle Switching fr equency Max. 6/min Switching time1.) Open: 10…20 ms Close: 40…60 ms Electrical data Operating voltage 24 V/UC, 110 V/UC, 230 V/UC; (36 V/UC on request) Power consumption Inrush 100 W Hold 9 W (after 500 ms) Voltage tolerance ± Current consumption at 30 % incr eased operating voltage

31.2 V =

7.60 A

143.0 V =

1.80 A

299.0 V =

0.76 A Medium data Oper ating medium Neutral fluids, e.g. drinking water or neutral gases, e.g. compressed air Medium temperature - °C…+ V iscosity (max.) 37 mm2/s Process/Port connection & communication Electrical connection Cable plug Type 2518 according to DIN EN 175 301 803, form A (included in deliver y), see “Cable plug Type 2518, form A according to DIN EN 175301 - 803” on page 18 Approvals and certificates Degree of protection IP65 with cable plug Environment and installation Installation position Any, preferably actuator face up Max. system pressure in flow direction 8 bar (switching pressure max. 3 bar depending on orifice) Ambient temperature - °C…+ 1.) Measurement at the valve outlet 6 bar and 20 °C. Opening: P ressure build-up 0…90 %, Closing: P ressure reduction 100…10 % 2.) UC - Universal Curr ent, AC and DC possible

5 | 19 Visit product website  2. Cir cuit functions Circuit functions Description 2 (A) 1 (P) Type: A, solenoid valve 2/2 way Direct-acting Normally closed 2 (B) 1 (P) Type: B, solenoid valve 2/2 way Direct-acting Normally opened 2(A) 1(P) 3(R) Type: C, solenoid valve 3/2 way Direct-acting Normally closed 2(B) 1(P) 3(R) Type: D, solenoid valve 3/2 way Direct-acting Normally opened 2(A) 1(P1) 3(P2) Type: E, mixing valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) Type: F, distribution valve (solenoid valve) 3/2 way Direct-acting

6 | 19 Visit product website  3. Mat erials 3.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? V erify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 3.2. 3/2 way br ass version No. Element Material

1 Coil Epoxy

2 Plunger Stainless steel 1.4105

3 Toggle pin PTFE

4 O-ring NBR, FKM, EPDM

5 Closing body NBR, FKM, EPDM

6 Housing Brass

7 O-ring NBR, FKM, EPDM

8 Lateral flange PC

9 Manual override with locking function

3.3. 3/2 way plastic version with union nut and connection fitting No. Element Material 2 Plunger Stainless steel 1.4105

4 Union nut PVC

5 O-ring FKM, EPDM

6 Connection fitting True union, threaded,

7 Body PVC

8 Closing body FKM, EPDM

9 O-ring FKM, EPDM

10 Lateral flange PC

11 Manual override with locking function

7 | 19 Visit product website  3.4. 2/2 way br ass version No. Element Material 2 Plunger Stainless steel 1.4105

6 Body Brass

3.5. 2/2 way plastic version with true union nut and connection fitting No. Element Material 2 Plunger Stainless steel 1.4105

4 True union nut PVC

11 Manual overide with locking function

3.6. 2/2 way br ass version for railway application No. Element Material 2 Plunger Stainless steel 1.4105 3 Toggle pin PTFE1.) 4 O-ring EPDM2.) 5 Closing body EPDM2.) 7 O-ring EPDM2.) 1.) PTFE suitable for drinking water 2.) EPDM with KTW and W270 certificate

8 | 19 Visit product website  4. Dimensions 4.1. 3/2 way br ass version Note: Dimensions in mm 127.5 35.7 52 L D L D D L 40 (87.5) DN SW 32 129 Material DN Connection D L Brass 10 Threaded G ⅜ 12 Brass 15 Threaded G ½ 14 Brass 20 Threaded G ¾ 16

9 | 19 Visit product website  4.2. 3/2 way plastic version with union nut and connection fitting Note: Dimensions in mm (11) ∅48 A DN D C B 128.5 117.5 35.7 Material DN Connection A B C D L 1 PVC 10 True union 30 17 14 Ø 16.2 130 Threaded connection 30 17 12 G ⅜ 130 Threaded connection 30 17 12 NPT ⅜ 130 10 (with port for DN 15) True union 32 19 16 Ø 20.2 134 Threaded connection 32 19 13 G ½ 134 Threaded connection 32 19 14 NPT ½ 134 15 True union 33 19 16 Ø 20.2 136 Threaded connection 33 19 13 G ½ 136 Threaded connection 33 19 14 NPT ½ 136 15 (with port for DN 20) True union 36 22 19 Ø 25.2 142 Threaded connection 36 22 15 G ¾ 142 Threaded connection 36 22 16 NPT ¾ 142 20 True union 37 22 19 Ø 25.2 144 Threaded connection 37 22 15 G ¾ 144 Threaded connection 37 22 16 NPT ¾ 144

10 | 19 Visit product website  4.3. 2/2 way br ass version for standard and railway application Note: Dimensions in mm ∅ 48 35.7 111.5 L L D D 87.5 SW 32 DN 119 Material DN Connection D L Brass 10 Threaded G ⅜ 12 Brass 15 Threaded G ½ 14 Brass 20 Threaded G ¾ 16

11 | 19 Visit product website  4.4. 2/2 way plastic version with true union nut and connection fitting Note: Dimensions in mm DN D C B 35.7 117.5 M5 10 Material DN Connection B C D L 1 L 2 PVC 10 True union 17 14 Ø 16.2 130 99.5 Threaded 17 12 G ⅜ 130 99.5 Threaded 17 12 NPT ⅜ 130 99.5 PVC 10 (with port for DN 15) True union 19 16 Ø 20.2 134 101.5 Threaded 19 13 G ½ 134 101.5 Threaded 19 14 NPT ½ 134 101.5 15 True union 19 16 Ø 20.2 136 103.0 Threaded 19 13 G ½ 136 103.0 Threaded 19 14 NPT ½ 136 103.0 15 (with port for DN 20) True union 22 19 Ø 25.2 142 106.0 Threaded 22 15 G ¾ 142 106.0 Threaded 22 16 NPT ¾ 142 106.0 20 True union 22 19 Ø 25.2 144 107.0 Threaded 22 15 G ¾ 144 107.0 Threaded 22 16 NPT ¾ 144 107.0

12 | 19 Visit product website  5. Device/P rocess connections 5.1. P in assignment Note: The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. In the table, compare the respective pin assignment with the corresponding circuit function. Circuit function Connection Connection Connection 3/2 way plastic version 3/2 way brass version C R P A 2 1 D P R B E P2 P1 A F B A P 6. Or dering information 6.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter

13 | 19 Visit product website  6.3. Or dering chart 3/2 way version, seal material EPDM Note: For detailed information on the circuit functions, see chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) G ⅜ 10 2.0 0…1 PVC X X – – G ½ 2.0 0…1 X X – – True union Ø 16 2.0 0…1 X X – – True union Ø 20 2.0 0…1 X X – – G ½ 15 4.0 0…0.5 X X – – True union Ø 20 4.0 0…0.5 X X – – True union Ø 25 4.0 0…0.5 X X – – G ¾ 20 5.0 0…0.25 X X – – True union Ø 25 5.0 0…0.25 X X – – D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) G ⅜ 10 2.0 0…1 X X X X G ½ 2.0 0…1 X X X X True union Ø 16 2.0 0…1 X X X X True union Ø 20 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 X X X X True union Ø 20 4.0 0…0.5 X X X X True union Ø 25 4.0 0…0.5 X X X X G ¾ 20 5.0 0…0.25 X X X X True union Ø 25 5.0 0…0.25 X X X X F, distribution valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) G ⅜ 10 2.0 0…1 X X X X G ½ 2.0 0…1 X X 076537  X True union Ø 16 2.0 0…1 055770  X 064266  052546  True union Ø 20 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 025876  X X X True union Ø 20 4.0 0…0.5 049883  X 058279  052071  True union Ø 25 4.0 0…0.5 X X X X G ¾ 20 5.0 0…0.25 X X X X True union Ø 25 5.0 0…0.25 067076  X 040921  054564  C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) G ⅜ 10 2.0 0…1 Brass X X – – G ½ 15 4.0 0…0.5 046648  X – – G ¾ 20 5.0 0…0.25 X X – – D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) G ⅜ 10 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 X X X X G ¾ 20 5.0 0…0.25 X X X X

14 | 19 Visit product website  Circuit function Port connection Orifice KV value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 F, distribution valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) G ⅜ 10 2.0 0…1 Brass X X X X G ½ 15 4.0 0…0.5 X X X 053634  G ¾ 20 5.0 0…0.25 X X X X X on request – version not possible 3/2 way version, seal material NBR Note: For detailed information on the circuit functions, see chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) G ⅜ 10 2.0 0…1 Brass 048997  059302  – – G ½ 15 4.0 0…0.5 062737  062481  – – G ¾ 20 5.0 0…0.25 X 049470  – – D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) G ⅜ 10 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 021964  X X 051556  G ¾ 20 5.0 0…0.25 X X X X F, distribution valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) G ⅜ 10 2.0 0…1 064025  X X 062960  G ½ 15 4.0 0…0.5 X X 045916  062124  G ¾ 20 5.0 0…0.25 140798  X 062119  079567  X on request – version not possible

15 | 19 Visit product website  3/2 way version, seal material FKM Note: For detailed information on the circuit functions, see chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) G ⅜ 10 2.0 0…1 PVC X X – – G ½ X X – – True union Ø 16 X X – – True union Ø 20 X X – – G ½ 15 4.0 0…0.5 X X – – True union Ø 20 X X – – True union Ø 25 X X – – G ¾ 20 5.0 0…0.25 X X – – True union Ø 25 X X – – D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) G ⅜ 10 2.0 0…1 X X X X G ½ X X X X True union Ø 16 X X X X True union Ø 20 X X X 172866  G ½ 15 4.0 0…0.5 X X X X True union Ø 20 X X X X True union Ø 25 4.0 0…0.5 X X X X G ¾ 20 5.0 0…0.25 X X X X True union Ø 25 X X X X F, distribution valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) G ⅜ 10 2.0 0…1 065194  X X 052183  G ½ X X X X True union Ø 16 058362  X X 052619  True union Ø 20 X X X X G ½ 15 4.0 0…0.5 X X X X True union Ø 20 058710  X X 050904  True union Ø 25 X 020687  X 042470  G ¾ 20 5.0 0…0.25 X X X X True union Ø 25 058363  X 068352  066280  C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) G ⅜ 10 2.0 0…1 Brass X X – – G ½ 15 4.0 0…0.5 X X – – G ¾ 20 5.0 0…0.25 X X – – D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) G ⅜ 10 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 X X X X G ¾ 20 5.0 0…0.25 X X X X F, distribution valve (solenoid valve) 3/2 way Direct-acting 4(A) 2(B) 1(P) G ⅜ 10 2.0 0…1 X X X X G ½ 15 4.0 0…0.5 053050  069814  X 058915  G ¾ 20 5.0 0…0.25 X X X X X on request – version not possible

16 | 19 Visit product website  2/2 way version, seal material EPDM Note: For detailed information on the circuit functions, see chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) G ⅜ 10 2.0 0…3 Brass X X X X G ½ 15 4.5 0…1 X X X 056281  G ¾ 20 6.0 0…0.5 X X X X B, solenoid valve 2/2 way Direct-acting Normally opened 2 (B) 1 (P) G ⅜ 10 2.0 0…2 X X X X G ½ 15 4.5 0…1 049793  X X X G ¾ 20 6.0 0…0.5 280187  289458  X X X on request – version not possible 2/2 way version, seal material FKM Note: For detailed information on the circuit functions, see chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) G ⅜ 10 2.0 0…3 PVC X X X X G ½ 2.0 0…3 086273  X X X True union Ø 16 2.0 0…3 047915  X 052953  050443  True union Ø 20 2.0 0…3 056060  X 055817  056789  G ½ 15 4.5 0…1 047398  X X 056663  True union Ø 20 4.5 0…1 053882  X 051641  050787  True union Ø 25 4.5 0…1 X X X 058369  G ¾ 20 6.0 0…0.5 X X X 056794  True union Ø 25 6.0 0…0.5 056495  X 050551  051351  B, solenoid valve 2/2 way Direct-acting Normally opened 2 (B) 1 (P) G ⅜ 10 2.0 0…2 X X – – G ½ 2.0 0…2 X X – – True union Ø 16 2.0 0…2 058361  053221  – – True union Ø 20 2.0 0…2 X X – – G ½ 15 4.5 0…1 X X – – True union Ø 20 4.5 0…1 047503  045439  – – True union Ø 25 4.5 0…1 X X – – G ¾ 20 6.0 0…0.5 X X – – True union Ø 25 6.0 0…0.5 051969  X – –

17 | 19 Visit product website  Circuit function Port connection Orifice KV value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 230/UC 024/50 230/50 A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) G ⅜ 10 2.0 0…3 Brass 054053  X 048664  044502  G ½ 15 4.5 0…1 025537  X X 040549  G ¾ 20 6.0 0…0.5 069752  X X 048622  B, solenoid valve 2/2 way Direct-acting Normally opened 2 (B) 1 (P) G ⅜ 10 2.0 0…2 X X X X G ½ 15 4.5 0…1 059360  046643  X X G ¾ 20 6.0 0…0.5 X X X X X on request – version not possible 2/2 way brass version for railway application Note: Detailed information on the circuit functions can be found in chapter “2. Circuit functions” on page 5. Circuit function Port connection Orifice K V value water Pressure range Body material Article no. per voltage/frequency [V/Hz] [inch resp. mm] [mm] [m 3/h] [bar] 024/UC 036/UC 110/UC 230/UC A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) G ⅜ 10 2.0 0…3 Brass 246791  X 246792  246793  G ½ 15 4.5 0…1 246789  X 242884  246790  G ¾ 20 6.0 0…0.5 239361  X 239348  246787  B, solenoid valve 2/2 way Direct-acting Normally opened 2 (B) 1 (P) G ⅜ 10 2.0 0…2 340223  X X X G ½ 15 4.5 0…1 X X X X G ¾ 20 6.0 0…0.5 X X X X X on request

18 | 19Visit product website  6.4. Or dering chart accessories Cable plug Type 2518, form A according to DIN EN 175301 - 803 Note: Further versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V AC/DC 314802  With LED (AC/DC) 12…24 V AC/DC 314812  With LED and varistor (AC/DC) 12…24 V AC/DC 314820  With rectifier, LED and varistor 12…24 V AC/DC 314816  Timer Type 1087, form A according to DIN EN 175301 - 803 Note: Further versions see data sheet Type 1087 Time control Approval Product code Voltage Article no. Analog – 1087-A-BCH-UC - 28 10…30 V AC/DC 348828  – 1087-A-BDK-UC 28 24…240 V AC/DC 348829  cURus 1087-A-BCH-UC 28*PU01 10…30 V AC/DC 348906  cURus 1087-A-BDK-UC 28*PU01 24…240 V AC/DC 348907  Digital – 1087-A-BFW-UC - 29 10…48 V AC/DC 348830  – 1087-A-BDX-UC 29 110…240 V AC/DC 348831  cURus 1087-A-BFW-UC 29*PU01 10…48 V AC/DC 348908  cURus 1087-A-BDX-UC 29*PU01 110…240 V AC/DC 348909  Note: P ossible for standard and railway application F or detailed information on the position feedback see data sheet Type 1060 The position feedback is mount ed on the coil and cannot be ordered separately. Please contact your Bürk ert representative if you are interested in a valve Type 0131 with position feedback. Position feedback Voltages1.) with feedback

24 V/UC

24 V/50

230 V/UC

230 V/50

1.) Other voltages available on request

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com