104S-C ALLEN-BRADLEY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Contactors & Control Relays 9-7 Safety Contactors 104S-C Product Selection Reversing AC-Operated Contactors

  • AC Operating Mechanism, 3 Main Contacts
  • Includes Mechanical/Electrical Interlock
  • Includes Reversing Power Wiring ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. ⊗ Coil Voltage Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09⊗ 210C becomes Catalogue Number 104S-C09D210C. Ie Ratings for Switching AC Motors Auxiliary Contacts Installed per Contactor Catalogue Number ! AC-2, AC-3, AC-4 [A] kW (50 Hz) HP (60 Hz) AC-3 AC-1 230V 400V 415V 500V 690V 1∅ 3∅ 115V 230V 200V 230V 460V 575V NO NC " 9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 06 104S-C09⊗ 012C 15 104S-C09⊗ 210C 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 06 104S-C12⊗ 012C 15 104S-C12⊗ 210C 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 06 104S-C16⊗ 012C 15 104S-C16⊗ 210C 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 06 104S-C23⊗ 012C 15 104S-C23⊗ 210C 30 65 10 15 15 15 2 5 7-1/2 10 20 25 05 104S-C30⊗ 010C 15 104S-C30⊗ 210C 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 05 104S-C37⊗ 010C 15 104S-C37⊗ 210C 43 85 13 22 25 22 3 7.5 10 15 30 30 05 104S-C43⊗ 010C 15 104S-C43⊗ 210C 6 0 1 0 0 1 8 . 5 3 23 73 2 5 1 01 52 04 05 0 05 104S-C60⊗ 010C 15 104S-C60⊗ 210C 7 2 1 0 0 2 24 04 54 0 5 1 52 02 55 06 0 05 104S-C72⊗ 010C 15 104S-C72⊗ 210C 85 100 25 45 55 45 7-1/2 15 25 30 60 60 05 104S-C85⊗ 010C 15 104S-C85⊗ 210C S t a n d a r d C o i l V o l t a g e 1 22 43 23 64 24 8 1 0 0 100- 110 110 120 127 200 200- 220 208 208- 240

50 Hz R K V W X Y KP – D P S KG L – –

60 Hz Q J – V – X – KP – D – – KG H L

50 Hz F – VA T – – – N – G B – M C –

Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing DC-Operated Contactors

  • DC Operating Mechanism, 3 Main Contacts, Line Side Coil Terminations
  • Includes Mechanical/Electrical Interlock
  • Includes Reversing Power Wiring ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. ⊗ Coil Voltage Suffix Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09⊗ 210C becomes Catalogue Number 104S-C09ZJ210C. Ie Ratings for Switching AC Motors Auxiliary Contacts Installed per Contactor Catalogue Number! AC-2, AC-3, AC-4 [A] kW (50 Hz) HP (60 Hz) AC-3 AC-1 230V 400V 415V 500V 690V 1∅ 3∅ 115V 230V 200V 230V 460V 575V NO NC " 9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 06 104S-C09⊗ 012C 15 104S-C09⊗ 210C 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 06 104S-C12⊗ 012C 15 104S-C12⊗ 210C 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 06 104S-C16⊗ 012C 15 104S-C16⊗ 210C 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 06 104S-C23⊗ 012C 15 104S-C23⊗ 210C 30 65 10 15 15 15 2 5 7-1/2 10 20 25 05 104S-C30⊗ 010C 15 104S-C30⊗ 210C 37 65 11 18.5/ 20 20 18.5 3 5 10 10 25 30 05 104S-C37⊗ 010C 15 104S-C37⊗ 210C 43 85 13 22 25 22 3 7.5 10 15 30 30 05 104S-C43⊗ 010C 15 104S-C43⊗ 210C 60 100 18.5 32 37 32 5 10 15 20 40 50 05 104S-C60⊗ 010C 15 104S-C60⊗ 210C 72 100 22 40 45 40 5 15 20 25 50 60 05 104S-C72⊗ 010C 15 104S-C72⊗ 210C 85 100 25 45 55 45 7-1/2 15 25 30 60 60 05 104S-C85⊗ 010C 15 104S-C85⊗ 210C DC Voltage 9 12 24 36 48 60 64 72 104S-C09…C43 Standard ZR ZQ ZJ ZW ZY ZZ ZB ZG w i t h I n t e g r a t e d D i o d e ——D J————— 104S-C60…C85 with Integrated Diode DR DQ DJ DW DY DZ DB DG DC Voltage 80 110 115 125 220 230 250 104S-C09…C43 Standard ZE ZD ZP ZS ZA ZF ZT w i t h I n t e g r a t e d D i o d e ——————— 104S-C60…C85 with Integrated Diode DE DD DP DS DA DF DT