Features
- Source/measure voltage and current
- 3 source ranges: 0 to 22 mA and 0 to 22 V
- 3 measure ranges: 0 to 70 mA and 0 to 50 V
- Accuracy 0.02 %
- Transmitter simulator/sink loop control
- Output steps and ramps
- Fine adjustment (inching)
- 20 hours typical battery life
- Optional mains power supply (230 V and 110 V available)
Applications
Common use of the 1048 is to simulate a transducer or measure the current flow in a transducer loop. The 1048 can be used to check a 4 to 20 mA system in either source or measure modes of operation, with the 24 V compliance voltage powering the loop when current source mode is selected. In the source mode, the 1048 may be used to calibrate meters, thermocouple indicators, data loggers, for signal injection, semiconductor characterisation, or as a backing off source. In the measure mode, the 1048 may be used in the same way as a digital multimeter, checking DC voltages and current over 3 ranges with excellent resolution and accuracy.
1048 Voltage / Current / Loop Calibrator
Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2b Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Voltage source Range Resolution Accuracy Output current Temp coefficient 0 to 220 mV 10 μV , 100 μV above 0.2 V 0.05 % of FS 20 mA ± 6 ppm/°C0 to 2.2 V 100 μV , 1 mV above 2 V 0.02 % of FS 0 to 22 V 1 mV , 10m V above 20 V 0.02 % of FS Voltage measure Range Resolution Accuracy Measure load Temp coefficient 0 to 220 mV 10 μV , 100 μV above 0.2 V 0.05 % of FS ± 1 digit 1 MΩ ± 3 ppm/°C0 to 2.2 V 100 μV , 1 mV above 2 V 0.02 % of FS ± 1 digit 1 MΩ 0 to 22 V 1 mV , 10 mV above 20 V 0.02 % of FS ± 1 digit 10 MΩ Current source Range Resolution Accuracy Output voltage Temp coefficient 0 to 220 μA 10 nA, 0.1 μA above 200 mA 0.05 % of FS 24 V Max ± 12 ppm/°C0 to 2.2 mA 0.1 μA, 1 μA above 2 mA 0.02 % of FS 0 to 22 mA 1 μA, 10 μA above 20 mA 0.02 % of FS Current measure Range Resolution Accuracy Input load Temp coefficient 0 to 220 μA 10 nA, 0.1 μA above 200 mA 0.05 % of FS ± 1 digit 1 kΩ ± 8 ppm/°C0 to 2.2 mA 0.1 μA, 1 μA above 2 mA 0.02 % of FS ± 1 digit 110 Ω 0 to 22 mA 1 μA, 10 μA above 20 mA 0.02 % of FS ± 1 digit 16 Ω Settings and General Specifications