© PHOENIX CONTACT 2016-07-14104460_en_04 PSI-MODEM-SHDSL/SERIAL Data sheet 1D e s c r i p t i o n The SHDSL-SERIAL permanent line modem allows the broadband networking of serial devices over in-house lines. A distance of up to 20 km can lie between two devices. The SHDSL modem operates transparently of the protocol and supports RS-232, RS-422 and RS-485 W2 interfaces. All devices have two SHDSL ports. You can easily set up point-to-point, redundant point-to-point, line and star topol- ogies. The clearly visible LEDs on the front of the device provide on-site technicians with quick device diagnostics. Every de- vice also has integrated diagnosis functions and a logbook. Two freely configurable digital outputs are available for alarm generation for external devices. You can parameter- ize them via the configuration software. Power is supplied via USB cable, which enables device configuration without external 24 V power supply. Areas of application –F o r i n - h o u s e c a b l e s – Point-to-point connection –S t a r t o p o l o g y – Line topology, up to 255 SHDSL devices SHDSL technology – Symmetrical data transmission – Two SHDSL ports – Up to 15.3 Mbps (2-wire), 30 Mbps (4-wire) Interfaces – RS-232, up to 230.4 kbps, automatic DCE/DTE switchover – RS-422, up to 2000 kbps – RS-485 W2, up to 2000 kbps, termination resistor can be connected Alarm outputs – Two digital outputs, in dividually configurable Via configuration software: – Online diagnostics, logbook function – Individual project configuration – Saving and printing of project and device configurations WARNING: Explosion hazard when used in potentially explosive areas The device is a category 3 item of electrical equipment. Follow the instructions provided here during installation and observe the safety notes. A combination of different SHDSL modems (e.g. SHDSL-SERIAL with SHDSL-Ethernet) is not possible. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products SHDSL-SERIAL permanent line modem

104460_en_04 PHOENIX CONTACT 2/9 2T a b l e o f c o n t e n t s

104460_en_04 PHOENIX CONTACT 3/9 3O r d e r i n g d a t a Description Ty pe Order No. Pcs./Pkt. SHDSL permanent line modem, for point-to-point, line, and star topologies on in-house 2 and 4-wire cables PSI-MODEM-SHDSL/SERIAL 2313669 1 Accessories Description Ty pe Order No. Pcs./Pkt. System power supply, primary switched Input voltage range Nominal output voltage Nominal output current 45 Hz ... 65 Hz 85 V AC ... 264 V AC

24 V DC ±1%

1.5 A MINI-SYS-PS-100- 240AC/24DC/1.5 2866983 1 DIN rail connector (2x required) ME 17.5 TBUS 1.5/ 5-ST-3.81 GN 2709561 1 Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal block (COMBICON), can alternatively be snapped onto DIN rail DT-TELE-SHDSL 2801593 1 USB cable, USB type A/mini-USB type B, 5-pos., 1 m PSI-CA-USB A/MINI B/1METER 2313575 1 m USB cable, USB type A/mini-USB type B, 5-pos., 3 m CABLE-USB/MINI-USB-3.0M 2986135 3 m RS-232 cable, for connecting the modem to a 9-pos. device interface, 2 m D-SUB 9/D-SUB 9 (socket/socket) PSM-KA9SUB9/BB/2METER 2799474 2 m RS-232 cable, for connecting the modem to a 9-pos. device interface, 0.5 m D-SUB 9/D-SUB 9 (socket/socket) PSM-KA9SUB9/BB/0.5METER 2708520 0.5 m Adapter cable to connect the IB IL RS232 and IB IL RS232- PRO Inline communication terminals to the interface con- verter, e.g., modem, Com server, Bluetooth or fiber optics. PSM-KAD-IL RS232/9SUB/B/0.8M 2319200 0.8 m

104460_en_04 PHOENIX CONTACT 4/9

4 Technical data

Supply voltage 18 V DC ... 30 V DC vi a plug-in COMBICON screw terminal block

24 V DC ±5 % (alternative or redundant, via DIN rail connec-

tor and system power supply unit)

5 V DC (configuration only, via mini-USB type B)

Nominal current consumption < 180 mA at 24 V LED indicator VCC (green LED) – Steady light: operation – Flashing at 1 Hz: supply via USB (for configuration) Switching outputs 2 x VNom/ 150 mA (the digital outputs cannot be used for power supply via the DIN rail connector), short-circuit-proof SHDSL interface Connection method 2 x 2-pos. COMBICON plug-in screw terminal block Type SHDSL interface according to ITU-T G.991.2.bis Transmission rate 4-wire operation 2-wire operation 64 kbps ... 30 Mbps (manual setting of the data rate) 384 kbps ... 11.39 Mbps (automatic detection of the data rate) 32 kbps ... 15.3 Mbps (manual setting of the data rate) 192 kbps ... 5.696 Mbps (automatic detection of the data rate) Transmission length Over 20 km possible at lower data rates and with good cable quality Status and diagnostics indicators 2 x LINK, 2 x STAT (DSL data traffic port A and port B) DIAG (yellow LED), diagnostic messages ERR (red LED), errors TERM (yellow LED), only relevant for RS-485 RS232 (yellow LED) RS-232 interface Connection method D-SUB 9-pos. plug Type RS-232 interface, according to ITU-T V.28, EIA/TIA-232, DIN 66259-1 Transmission rate Can be freely para meterized from 92 bps ... 230.4 kbps Transmission length Maximum 15 m Supported protocols Software handshake (Xon/Xoff), hardware handshake (RTS/CTS), 3964R-compatible, Modbus RTU/ASCII, transparent protocol - other protocols supported Data format/coding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length

104460_en_04 PHOENIX CONTACT 5/9 RS-422 interface Connection method Plug-in/screw connection via COMBICON plug Type RS-422 interface, according to ITU-T V.11, EIA/TIA-422, DIN 66348-1 Transmission rate Can be freely pa rameterized from 92 bps ... 2 Mbps Transmission length Maximum 1200 m Supported protocols Modbus RTU/ASC II and others, transparent protocol Data format/coding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length RS-485 interface Connection method Plug-in/screw connection via COMBICON plug Type RS-485 interface, according to EIA/TIA-485, DIN 66259- 4/RS-485 2-wire Transmission rate Can be freely pa rameterized from 92 bps ... 2 Mbps Transmission length Maximum 1200 m Supported protocols Modbus RTU/ASC II and others, transparent protocol Data format/coding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length USB interface (configuration/diagnostics) Connection method Mini-USB type B, 5-pos. Type USB 2.0 Transmission length Maximum 5 m, only for configuration and diagnostics General data Ambient temperature range Operation (no other modules supplied via the device): – Freestanding (40 mm spacing) – Connected in series (low power dissipation of mod- ules connected in series) – Connected in series (without restrictions) -20°C ... +60°C -20°C ... +55°C -20 °C ... +50 °C Operation (other modules supplied via the device (max.

1.5 A))

-20 °C ... +45 °C Storage/transport -40 °C ... +85 °C Housing ME 35 with 5-pos. bus contact and ground contact Material PA 6.6-FR, V0, green Dimensions (H x W x D) 99 x 35 x 114.5 mm Weight 205 g Functional earth ground Housing contact to DIN rail Degree of protection IP20 Electrical isolation DIN EN 50178 (Supply // RS-485, RS-422 // DSL port A // DSL port B // FE)

104460_en_04 PHOENIX CONTACT 6/9 SN 29500 standard, temperature 25°C, operating cycle 21% (5 days a week, 8 hours a day) 693 years SN 29500 standard, temperature 40°C, operating cycle 34.25% (5 days a week, 12 hours a day) 301 years SN 29500 standard, temperature 40°C, operating cycle 100% (7 days a week, 24 hours a day) 121 years Test voltage 1.5 kVrms, 50 Hz, 1 min. Vibration resistance According to IEC 60068-2-6: 5 g, 150 Hz Shock resistance 15g in each space direction, according to IEC 60068-2-27 Noise emission EN 55011 Noise immunity EN 61000-6-2 Electromagnetic compatibility Conform ity with EMC Directive 2014/30/EU UL, USA/Canada UL 508 listed Manufacturer's declaration EN 50121-4 (Railw ay applications - Electromagnetic com- patibility, Part 4: Emission and Immunity of the Signaling and Telecommunications Apparatus) Exceptions include installations within the 3 m area and safety-related devices. For these devices, there are further requirements according to EN 50121-4 Table 1, Note 1. Section 1, Paragraph 3 of EN 50121-4 applies. Phoenix Contact QUINT power supply units are to be used directly on the device. ATEX X II 3 G Ex nA nC IIC T4 Gc X General data [...]

104460_en_04 PHOENIX CONTACT 7/9

5 Safety regulations and installation notes

5.1 Installation notes

  • The category 3 device is designed for installation in Zone 2 potentially explosive areas. It meets the require- ments of EN 60079-0:2012+A11:2013 and EN 60079-15:2010.
  • Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installa- tion instructions as described. When installing and op- erating the device, the applicable regulations and safety directives (including national safety directives), as well as the general codes of practice, must be ob- served. The safety data is provided in the packing slip and on the certificates (conformity assessment, addi- tional approvals where applicable).
  • Do not open or modify the device. Do not repair the de- vice yourself; replace it with an equivalent device in- stead. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for dam- age resulting from violation.
  • The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry envi- ronment. Do not subject the device to mechanical and/or thermal loads that exceed the specified limits.
  • This device is not designed for use in atmospheres with a risk of dust explosions.
  • The device is designed exclusively for operation with safety extra-low voltage (SELV) according to IEC 60950/EN 60950/VDE 0805. The device may only be connected to devices that meet the requirements of EN 60950.

5.2 Installation in zone 2

  • Observe the specified conditions for use in potentially explosive areas!
  • Install the device in a suitable, approved housing (with at least IP54 protection) that meets the requirements of EN 60079-15. For this purpose, observe the require- ments of IEC 60079-14 / EN 60079-14.
  • Only connect devices to the supply and signal circuits in zone 2 that are suitable for operation in the Ex zone 2 and for the conditions at the installation location.
  • In potentially explosive areas, snap the device on or off the DIN rail connector and connect or disconnect the cables only when the power is disconnected.
  • The mini-USB configuration interface may only be used if it has been ensured that there is no explosive atmo- sphere.
  • Connection to the D-SUB interface is only permitted if the screw connection is fully tightened.
  • The device must be stopped and immediately removed from the Ex area if it is damaged, was subjected to an impermissible load, stored incorrectly or if it malfunc- tions.

5.3 UL notes

WARNING: Observe the following safety notes when us- ing the device. WARNING: Explosion hazard when used in potentially explosive areas Make sure that the following notes and in- structions are observed.

104460_en_04 PHOENIX CONTACT 8/9 6R a n g e The maximum possible SHDSL data rate depends on sev- eral parameters. Two important parameters are the cable length and cable cross section. Figure 1 SHDSL data rate depending on the distance, 2-wire The diagram illustrates the dependency of the maximum SHDSL data rate on the line length with 3 cable types. Lon- ger distances can be achieved using high-quality cables with larger diameters. The industrial permanent line modems enable data rates in 2-conductor operation from 32 kbps to 15.3 Mbps. Data rates of up to 30 Mbps are possible in 4-conductor opera- tion. SHDSL permanent line modems are suitable for in-house cables, not for public telephone networks. [km] [Mbps] 02468 1 0 1 2 1 4 1 6 1 8 2 0 = PE 1,4 mm (1,54 mm )² = PE 0,9 mm (0,64 mm )² = PE 0,4 mm (0,13 mm )²

104460_en_04 9/9PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com

7 Application examples

7.1 Point-to-point connection

7.2 Linear topology

Atypical application cases are also supported, e.g. the linear topology of multiple RS-232 interfaces or a mixed operation using different interfaces. The customer does, however, then need his custom protocol. The SHDSL modem trans- mits the data protocol transparently.

7.3 Star topology

The devices are connected via the DIN rail connector (TBUS) in the head station. The DIN rail connector supports RS-485. It can only be used with RS-232 and RS-422. In order to configure a star topology, you must create sev- eral line topologies. In the example, you have to create two linear topologies each comprising three devices. For more information, please refer to the UM EN PSI-MODEM-SHDSL/SERIAL user manual. SHDSL SHDSL RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 SHDSL 2 Wire SHDSL SHDSL RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 SHDSL 4 Wire SHDSL SHDSLSHDSL RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 A CB C B A SH DSL SH DSL SH DSL SH DSL SH DSL SH DSL SH DSL SH DSL SH DSL RS 485 RS 485 RS485 RS 485 RS 485 SH DSL SH DSL SH DSL A C D F B E Line 1 Line 2 B E C D FA