https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 1 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Sensor/actuator panel-mount connector, 4-pos., M12 push-pull, D-coded, rear/screw mounting with M16 thread, with straight solder connection Your advantages Established M12 standard for secure transmission of signals, data, and power Easy and quick cabling of devices and systems in hard-to-reach areas Manufacturer-independent M12 push-pull locking system for maximum availability Reliable shield connection even under extreme mechanical strain Compatible with connectors with screw or push-in connection Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626533902 Technical data Dimensions Length of cable 0.5 m Ambient conditions Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket) Degree of protection IP67 General Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Rated current at 40°C 4 A Rated voltage 250 V

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 2 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Technical data General Rated surge voltage 2.5 kV Number of positions 4 Insulation resistance ≥ 100 MΩ Coding D-coded Standards/regulations M12 connector IEC 61076-2-101 Push-pull Signal type/category Universal Status display No Overvoltage category II Degree of pollution 3 Connection method Individual wires Insertion/withdrawal cycles > 100 Torque 3 Nm ... 4 Nm (Installation-side) Mounting type Rear mounting M16 x 1.5 With flat nut Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Au Contact carrier material PA 6.6 Material of grip body Nickel-plated brass Material, knurls Nickel-plated brass Material Brass, nickel-plated Sealing material NBR/FKM Additional material specifications PU 2K (Grout material) Cable Cable type TPE litz wire Conductor cross section 0.34 mm² AWG signal line 22 Conductor structure signal line 7x 0.25 mm Core diameter including insulation 1.2 mm ±0.07 mm Thickness, insulation 0.21 mm Wire colors Yellow, orange, white, blue Conductor material Tin-plated Cu litz wires Standards/specifications M12 connector IEC 61076-2-101 Push-pull Insulation resistance ≥ 20 MΩ*km Conductor resistance ≤ 57.6 mΩ/m Nominal voltage, cable 300 V Test voltage, cable 2000 V AC Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation) -25 °C ... 85 °C (cable, flexible installation)

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 3 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Technical data Standards and Regulations Standards/specifications M12 connector IEC 61076-2-101 Push-pull Flammability rating according to UL 94 V0 Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.

  • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
  • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
  • The products are suitable for applications in plant, controller, and electrical device engineering.
  • When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
  • Assembled products may not be manipulated or improperly opened.
  • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
  • When using the product in direct connection with third-party manufacturers, the user is responsible.
  • For operating voltages > 50 V AC, conductive connector housings must be grounded
  • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
  • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product
  • Only use tools recommended by Phoenix Contact
  • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
  • Ensure that the protective or functional ground has been properly connected. applicable when combining several circuits in a cable and/or connector
  • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 4 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Technical data Environmental Product Compliance For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Dimensional drawing Technical drawings can be found under Downloads

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 5 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Diagram I = current strength, T = ambient temperature Classifications eCl@ss eCl@ss 10.0.1 27440103 eCl@ss 8.0 27440103 eCl@ss 9.0 27440103 ETIM ETIM 6.0 EC002061 Approvals Approvals Approvals cULus Recognized / EAC Ex Approvals Approval details

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 6 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Approvals cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E221474-20140616 Nominal voltage UN 250 V Nominal current IN 4 A mm²/AWG/kcmil 22-20 EAC B.01687 Accessories Accessories Plug for cable screw gland Screw plug - PROT-M12 - 1680539 An M12 screw plug for the unoccupied M12 sockets of the sensor/actuator cable, boxes and flush-type connectors Screw plug - PROT-M12 SH - 1503302 An M12 screw plug for the unoccupied M12 sockets of the shielded sensor/actuator cable, boxes and flush-type connectors Screw plug - PROT-M12 FB - 1555538 M12 high-grade steel screw plug, for unoccupied M12 sockets of the sensor/actuator cables, boxes and flush-type connectors for the food industry Seal

https://www.phoenixcontact.com/pi/products/1027670 09/02/2020 Page 7 / 7 Flush-type connector - SACC-DSI-FSD-4CON-M16/0,5 PP - 1027670 Accessories Flat gasket - SACC-M16-SEAL CLM - 1430394 M16 flat gasket, for rear mounting of M12 flush-type connectors with M16 fastening thread Flat nut - SACC-E-MU-M16 - 1504097 Flat nut with M16 thread Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8

32825 Blomberg

Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com