102504 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
© PHOENIX CONTACT - 05/2006Data Sheet INTERFACE 102504_04_en 1PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany Phone: +49-(0) 5235-3-00 • Fax: +49-(0) 5235-3-4 12 00 • www.phoenixcontact.com www.phoenixcontact.com/salesnetwork MCR-SL-S-...00-U(I)-(LP)
Description
The MCR-SL-S-... current measuring transducers provide the user with the opportunity of retrofitting the current mea- suring transducer in an existing system without interruption. This is made possible by an open up coil that functions on the Rogowski principle. Insulated conductors on the primary side with a diameter of up to 18.5 mm can be embraced. The current measuring transducers are electrically isolated from one another on the input and output side. The MCR-SL-S-...-U current measuring transducers con- vert sinusoidal and non-sinusoidal alternating currents up to The measuring ranges for input and output can be selected via a switch. The MCR-SL-S-...-I-LP current measuring transducers con- vert sinusoidal and non-sinusoidal alternating currents up to 400 A into the analog standard signal of 4...20 mA. The measuring range at the output is set with a switch. On the output side, the current measuring transducers are oper- ated in a 4...20 mA current loop, which simultaneously pro- vides the power supply for the modules, which is necessary for signal conversion. POWER I U OUTIN I OUT IN POWER I Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at This data sheet is valid for all products listed on the following page: Current Measuring Transducer for Sinusoidal and Non-Sinusoidal Alternating Currents
MCR-SL-S-...00-U(I)-(LP) 102504_04_en PHOENIX CONTACT 2 Ordering Data Technical Data Description Type Order No. Pcs./Pkt MCR current measuring transducer, for measuring sinusoidal and non-sinu- MCR-SL-S-100-U 2813457 1 MCR current measuring transducer, for measuring sinusoidal and non-sinu- MCR-SL-S-200-U 2813460 1 MCR current measuring transducer, for measuring sinusoidal and non-sinu- MCR-SL-S-400-U 2813473 1 MCR current measuring transducer, for measuring sinusoidal and non- sinusoidal alternating currents, input current 0...100 A, loop-powered output with 4...20 mA MCR-SL-S-100-I-LP 2813486 1 MCR current measuring transducer, for measuring sinusoidal and non- sinusoidal alternating currents, input current 0...200 A, loop-powered output with 4...20 mA MCR-SL-S-200-I-LP 2813499 1 MCR current measuring transducer, for measuring sinusoidal and non- sinusoidal alternating currents, input current 0...400 A, loop-powered output with 4...20 mA MCR-SL-S-400-I-LP 2813509 1 Supply voltage 20 V DC ... 30 V DC Current consumption < 30 mA – Transmission error < ±1% of end value Cable position error < 0.63% Temperature coefficient < 0.035%/K < 0.025%/K Step response (10% ... 90%) < 340 ms Degree of protection IP20 Test voltage 5 kV, 50 Hz, 1 min. Ambient temperature range -20°C ... +60°C Dimensions (W x H x D) 55 mm x 67 mm x 85 mm Housing design Polyamide PA non-reinforced, green Electromagnetic compatibility c compliant Response threshold 1% of end value Frequency range 30 Hz ... 6000 Hz Curve type Sinusoidal and non-sinusoidal Overload capacity (continuous) No limitation Surge strength (for 1 s) No limitation Connection method Clamp-on cable design for 18.5 mm ∅ (insulated conductor) Load ≥ 10 kΩ (UB - 12 V) / 20 mA Approvals UL/C-UL Listed UL 508 Yes UL/C-UL Listed UL 1604 Class I, Division 2 In preparation