GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 3 100ACDRS_S – Rev. 2021-1.0 Specifications subject to change without notice. 100ACDRS_S Series 100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply Universal 85-264VAC or 120-370VDC input voltage Accepts AC or DC input (dual-use of same terminal) Operating ambient temperature range -40°C to +70°C High I/O isolation test v oltage up to 4000VAC Industrial product technology design Low standby power consumption, high efficiency Over-voltage class III (Designed to meet EN61558-1 safety standards) Low ripple & noise Output short circuit, over-current, over-voltage protection Withstand 300VAC surge input for 5s DIN rail TS35X7.5/ TS35X15 mountable AC-DC Converter 100 Watt The 100ACDRS_S series fis eaturing a cost-effective, energy efficient solution for standard DIN-rail mounting. The products offer a high level of stability and immunity to noise, compliant with international IEC62368 standards for EMC and safety sepecifitions meet IEC/EN61000-4, CISPR32, EN55032, UL62368, IEC62368 and EN62368. These light weight AC-DC converters also have an extremely compact design for space saving and are ideal for applications such as industrial control equipment machinery and all kinds of applications in a harsh environment. Example: 100ACDRS_48S 100 = 100 Watts; AC = AC-DC; DR = Din Rail; S = Case style; 48 = Vout; S = Single Output; Output specifications Item Test conditions Min Typ Max Units Output voltage accuracy Line regulation Rated load ±0.5 % Load regulation 230VAC ±1.5 % Ripple & Noise* 20MHz bandwidth (peak-to-peak value)
- 12V Output
- 15V Output
- 24V Output
- 48V Output 120 120 150 240 mV mV mV mV Temperature Coefficient ±0.03 %/°C Stand-by Power Consumption 230VAC Input
- 12V/15V Output
- 24V Output
- 48V Output 0.30 0.35 0.40 W W W Switching frequency 65 KHz Minimum Load 0 % Start-up Time 3 s Hold-up Time 230VAC 30 ms * The “Tip and barrel method” is used for ripple and noise test, please refer to AC-DC Converter Application Notes for specific information. Protection specifications Over-load protection 110% - 200% Io, self-recovery Over-voltage protection 12V Output 15V Output 24V Output 48V Output ≤20V ≤25V ≤35V ≤60V Common specifications Short circut protection: Hiccup, continuous, self-recovery Operation temperature range: -40°C~+70°C Storage temperature range: -40°C ~+85°C Storage humidity range: < 95% RH Operating Altitude: 2000m Power Derating: -40°C to -30°C
- 12V/48V Output 3.0 %/cmin
- 24V Output 7.0 %/°C min
- 15V Output 8.0 %/°C min +50°C to +70°C 2.0 %/°C min 85VAC - 100VAC 0.67 %/VAC Safety standards: UL62368-1/IEC62368-1 Safety Approval EN62368-1 (Report) Design refer to EN61558-1 Safety Class: CLASS II MTBF(using MIL-HDBK-217F@25°C): >300,000 hours Case material: Plastic, heat-resistant (UL94V-0) Cooling: Free air convection Dimensions: 70.00 x 92.66 x 58.00 mm Weight: 235g Typ. Isolation specifications Item Test condition Min Typ Max Units Isolation Test (Input - Output) Electric Strength Test for 1min., ( leakage current°C 5mA )
4000 VAC
Note: 1. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta = 25°C, humidity <75% with nominal input voltage and rated output load; 2. All index testing methods in this datasheet are based on our company corporate standards; 3. We can provide product customization service, please contact our technicians directly for specific information; 4. Specifications are subject to change without prior notice. 5. Products are related to laws and regulations: see „Features“ and „EMC“; 6. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units. UL-62368-1 (E347551) Input specifications Item Test conditions Min Typ Max Units Input Voltage Range AC input DC input 120 264 370 VAC VDC Input Frequency 47 63 Hz Input Current 115VAC 230VAC 1.6 A A Inrush Current 115VAC 230VAC A A Leakage Current 264VAC 0.5mA RMS Max. Hot Plug Unavailable
GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 3 100ACDRS_S – Rev. 2021-1.0 Specifications subject to change without notice. 100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply 100ACDRS_S Series EMC specifications Emissions CE CISPR32/EN55032 CLASS B Emissions RE CISPR32/EN55032 CLASS B Immunity ESD IEC/EN61000-4-2 Contact ±6KV/Air ±8KV Perf. Criteria A Immunity RS IEC/EN61000-4-3 10V/m perf. Criteria A Immunity EFT IEC/EN61000-4-4 ±4KV perf. Criteria A Immunity Surge IEC/EN61000-4-5 line to line ±2KV perf. Criteria A Immunity CS IEC/EN61000-4-6 10Vr.m.s perf. Criteria A Immunity Voltage dips, short interruptions and voltage variations immunity IEC/EN61000-4-11 0%, 70% perf. Criteria A Approval Part Number Power [W] Output [Vo, VDC] Rated Current [A] Output Voltage Adjustable [Range, V]* Efficiency at 230VAC [%, Typ.] Capacitive Load [μF, Max.] UL 100ACDRS_12S 90 12V 7.5A 12.0 - 13.8 88 10000 UL 100ACDRS_15S 97.5 15V 6.5A 13.5 - 18.0 89 6400 UL 100ACDRS_24S 100.8 24V 4.2A 21.6 - 29.0 90 2500 UL 100ACDRS_48S 100.8 48V 2.1A 43.2 - 55.2 90 1100 * The actual adjustment range may extend outside the values stated, care should be exercised to ensure that the output voltage and power levels remain within the published maximum values. Product Selection Guide Typical characteristics Efficiency Note: 1. With an AC input between 85-100VAC and a DC input between 120-140VDC, the output power must be derated as per temperature derating curves; 2. This product is suitable for applications using natural air cooling; for applications in closed environment please consult factory or one of our FAE. 100ACDRS_24S 100ACDRS_48S 100ACDRS_12S 12/48V 24V 15V 100ACDRS_24S 100ACDRS_12S 100ACDRS_48S
GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 3 of 3 100ACDRS_S – Rev. 2021-1.0 Specifications subject to change without notice. 100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply 100ACDRS_S Series Mechanical dimensions