1007352 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 1 / 6 Special function module - AXL F PWM2 1H - 1007352 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F, function module, pulse width modulation, transmission speed in local bus 100 Mbps, IP20 degree of protection, including bus base module and Axioline F male connectors Product Description The module is designed for use within an Axioline F station. Two channels that operate independently of one another offer the option of pulse width modulation (PWM) for the output signals. The module supports PWM, pulse generator, and push-pull output operating modes. Your advantages 2 independent channels Output of 5 V and 24 V signals Push-pull output Nominal current per output: 500 mA (at 24 V DC), 10 mA (at 5 V DC) Frequency output (0 Hz ... 65535 Hz) Frequency resolution can be configured using the divider (1 Hz, 0.1 Hz, 0.01 Hz) Pulse width resolution can be configured using the divider (1 ms, 0.1 ms, 0.01 ms) Configurable pulse duty factor (0 % ... 100 %) Device rating plate stored Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626478869 Weight per Piece (excluding packing) 180.000 g Custom tariff number 85389091 Country of origin Germany
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 2 / 6 Special function module - AXL F PWM2 1H - 1007352 Technical data Dimensions Width 35 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 General Mounting type DIN rail Color traffic grey A RAL 7042 Net weight 171.06 g Note on weight specifications with connectors and bus base module Degree of pollution 2 (IEC 60664-1, EN 60664-1) Mounting position any (no temperature derating) Interfaces Designation Axioline F local bus Number 2 Connection method Bus base module Transmission speed 100 Mbps Axioline potentials Designation Axioline F local bus supply (UBus) Supply voltage 5 V DC (via bus base module) Current consumption max. 150 mA Power consumption max. 0.75 W Designation Supply voltage input UO Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC including all tolerances, including ripple Current consumption max. 1.1 A Power consumption max. 33 W (of which 1.3 W internal losses)
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 3 / 6 Special function module - AXL F PWM2 1H - 1007352 Technical data Axioline potentials Protective circuit Surge protection electronic (35 V, 0.5 s) Reverse polarity protection parallel diode; with external 1 A fuse (for start- up only) Digital outputs Output name PWM outputs Operating mode PWM, pulse generator, push-pull output Connection method Push-in connection Connection technology 2-conductor Number of outputs 2 Frequency range 0 Hz ... 65535 Hz Pulse duty factor 0 % ... 100 % Nominal output voltage 24 V (UO - 1.1 V)
5 V DC
Nominal current IN max. 500 mA (at 24 V DC) max. 10 mA (at 5 V DC) Nominal load, ohmic max. 12 W (at 24 V DC nominal voltage) max. 50 mW (at 5 V DC nominal voltage) Nominal load, inductive max. 12 VA (at 24 V DC nominal voltage) max. 50 mVA (at 5 V DC nominal voltage) Nominal load, lamp max. 6 W (at nominal voltage) Short-circuit-proof yes Short-circuit current typ. 24 mA (5 V output) Transient surge protection yes Standards and Regulations Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Interference emission Noise emission test according to EN 61000-6-3 Class B Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 4 / 6 Special function module - AXL F PWM2 1H - 1007352 Technical data Standards and Regulations Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Protection class III (IEC 61140, EN 61140, VDE 0140-1) Overvoltage category II (IEC 60664-1, EN 60664-1) Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Connection diagram L01 Connection example Dimensional drawing 35 54 122,4126,1 Classifications eCl@ss eCl@ss 10.0.1 27242605 eCl@ss 11.0 27242605 eCl@ss 6.0 27242600 eCl@ss 7.0 27242605 eCl@ss 9.0 27242605 ETIM ETIM 6.0 EC001601 ETIM 7.0 EC001601 Approvals Approvals
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 5 / 6 Special function module - AXL F PWM2 1H - 1007352 Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cULus Listed Accessories Accessories Device marking Insert label - EMT (35X28)R - 0801602 Insert label, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: snapped into marker carrier, lettering field size: 35 x 28 mm, Number of individual labels: 500 DIN rail connector
https://www.phoenixcontact.com/us/products/1007352 05/20/2021 Page 6 / 6 Special function module - AXL F PWM2 1H - 1007352 Accessories Bus connector - AXL F BS H - 2700992 Axioline F bus base module for housing type H Shield connection Shield connection - AXL SHIELD SET - 2700518 Axioline shield connection set (contains 2 shield bus holders and 2 SK 5 shield connection clamps) Terminal marking Zack marker strip - ZB 20,3 AXL UNPRINTED - 0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER Zack Marker strip, flat - ZBF 10/5,8 AXL UNPRINTED - 0829580 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 10.15 mm, lettering field size: 4 of 10.15 x 5 mm and 1 of 5.8 x 5 mm, Number of individual labels: 50 Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com