DIESEL ENGINE-GENERATOR SET 1000-XC6DT2 1000 ekW / 60 Hz / Standby 900 ekW / 60 Hz / Prime 208 - 4160V A tognum grouP BrAnd SySTEm RATINGS Standby Voltage (L-L) 208V 240V 480V 600V 4160V Phase 3 3 3 3 3 Hz 60 60 60 60 60 kW 1000 1000 1000 1000 1000 kVA 1250 1250 1250 1250 1250 AMPS 3470 3007 1504 1203 173 skVA@30% Voltage Dip 2600 2600 2600 1550 2600 Generator Model* 741RSL4045 741RSL4045 575RSL4044 741RSS4282 742FSM4364 Temp Rise 130°C/27°C 130°C/27°C 130°C/27°C 125°C/40°C 130°C/27°C Connection 12 LEAD LOW WYE 12 LEAD HI DELTA 4 BAR WYE 4 LEAD WYE 6 LEAD WYE Prime Voltage (L-L) 208V 240V 480V 600V 4160V Phase 3 3 3 3 3 Hz 60 60 60 60 60 kW 900 900 900 900 900 kVA 1125 1125 1125 1125 1125 AMPS 3123 2706 1353 1083 156 skVA@30% Voltage Dip 2600 2600 2600 1550 2600 Generator Model* 741RSL4045 741RSL4045 575RSL4044 741RSS4282 742FSM4364 Temp Rise 105°C/40°C 105°C/40°C 105°C/40°C 105°C/40°C 105°C/40°C Connection 12 LEAD LOW WYE 12 LEAD HI DELTA 4 BAR WYE 4 LEAD WYE 6 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered
// Engine Air Cleaners Oil Pump Full Flow Oil Filter Jacket Water Pump Inter Cooler Water Pump Closed Crankcase Vent Thermostats Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electric Isochronous Base - Structural Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130°C Standby Temperature Rise
1 Bearing, Sealed
125% Rotor Balancing 3-Phase Voltage Sensing ±.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content // digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator
16 Programmable Contact Inputs
7 Contact Outputs
UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA1 10 Level Compatible STANDARD EQUIPmENT // EPA Tier 2 Certified // Engine-Generator Set Tested to ISO 8528-5 for Transient Response // UL2200, CSA Listing Offered // Accepts Rated Load in One Step Per NFPA 1 10, Level 1 // All engine-generator sets are prototype and factory tested // MTU Onsite Energy is a single source supplier // Global Product Support // 2 Year Standard Warranty // Custom Design for Any Application // 16V-2000 G84 Diesel Engine - 31.8 Liter Displacement - Electronic Unit Pump Injection - 4-Cycle // Complete Range of Accessories // Permanent Magnet Generator (PMG) - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings // Digital Control Panel(s) - UL Recognized, , NFPA 1 10 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan FACTS
// Engine Manufacturer MTU Detroit Diesel Model 16V-2000 G84 Type 4-Cycle Arrangement 16-V Displacement: Cu In (lit) 1,943 (31.8) Bore: in (cm) 5.1 (13) Stroke: in (cm) 5.9 (15) Compression Ratio 16:1 Rated RPM 1,800 Engine Governor ADEC Max Power: Standby: bhp (kWm) 1,495 (1,115) Max Power: Prime: bhp (kWm) 1,354 (1,010) Regulation ±.25% Frequency 60 Hz Air Cleaner Dry // Liquid Capacity (Lubrication) Total Oil System: gal (lit) 26.9 (102) Engine Jacket Water Capacity: gal (lit) 34.3 (130) After Cooler Water Capacity: gal (lit) 5.3 (20) System Coolant Capacity: gal (lit) 105.6 (400) // Electrical Electric Volts DC 24 Cold Cranking Amps Under 0°F (-17.8°C) 1,900 // Fuel System Fuel Supply Connection Size 3/4” NPT Fuel Return Connection Size 1/4” NPT Maximum Fuel Lift: ft (m) 10 (3) Recommended Fuel Diesel #2 Total Fuel Flow: gal/hr (lit/hr) 127 (480) // Fuel Consumption STANDBY PRIME At 100% of Power Rating: gal/hr (lit/hr) 71 (269) 65.2 (247) At 75% of Power Rating: gal/hr( lit/hr) 55.6 (211) 51.3 (194) At 50% of Power Rating: gal/hr (lit/hr) 36.7 (139) 33.4 (126) // Cooling - radiator System STANDBY PRIME Ambient Capacity of Radiator: °F (°C) 122 (50) 122 (50) Max. Restriction of Cooling Air, Intake, Water Pump Capacity: gpm (lit/min) 220 (833) 220 (833) After Cooler Pump Capacity: gpm (lit/min) 68 (258) 68 (258) Heat Rejection to Coolant: BTUM (kW) 25,022 (440) 23,316 (410) Heat Rejection to After Cooler: BTUM (kW) 16,492 (290) 14,786 (260) Heat Radiated to Ambient: BTUM (kW) 5,427 (95) 4,971 (87.4) // Air requirements STANDBY PRIME Aspirating: *SCFM (m3/min) 2,860 (84) 2,755 (78) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) 40,013 (1,133) 40,013 (1,133) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 12,238 (349) 11,211 (319) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) // Exhaust System STANDBY PRIME Gas Temp. (Stack): °F (°C) 1,085 (585) 1,058 (570) Gas Volume at Stack Temp: CFM (m3/min) 7,416 (210) 6,992 (198) Maximum Allowable APPLICATION DATA
© MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 // tognum group Companies: Europe / middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // uSA / Canada / mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for Hotmodule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com EmISSIONS DATA nox + nmHC Co Pm 5.5 1.44 0.131 All units are in g/hp-hr and are EPA d2 cycle values. Emission levels of the engine may vary as a function of ambi- ent temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under cont- rolled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaran- teed to be below the US EPA Standards at the US EPA defined conditions. RATING DEFINITIONS AND CONDITIONS // Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capa- bility for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. // Deration Factor: Altitude: 1.8% per 1,640 ft (500 m) above 3,281 ft temperature: 1.0% per 9°F (5°C) over 1 13°F (45°C) at 328 ft (100 m). *Contact factory for deration above 8,202 ft (2,500 m). WEIGhTS AND DIMENSIONS SOUND DATA unit type Standby Full Load Standby no Load Prime Full Load Prime no Load OPU w/Critical Grade Muffler (dBA) 101.5 94 100 94 Sound Attenuated Enclosure (dBA) 93.5 86 92 86 System dimensions (L x W x H) Weight (less tank) OPU 192.8 x 68 x 101.6 in (4,900 x 1,730 x 2,480 mm) 17,636 lb (8,000 kg) Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. Materials and specifications subject to change without notice. Measurements for sound data are taken at 23 ft (7 m). Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.