SHC071 STEGO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
20 m<_ 20 m<_ 20 m<_ PRODUKTKATALOG - STEGO SENSOR HUB & SENSORS SHC 071 | IO-Link, DC 24 V, 4 Sensor Ports TECHNICAL DATA Sensor connection 4 ports with strain relief for up to 4 STEGO sensors1 IO-Link connection M12 round plug connector, IEC 61076-2-101, 4-pin, A-coded Electrical protection Reverse-polarity, short circuit, overvoltage protection Mounting clip for 35 mm DIN rail, EN 60715 and screw mounting (M5) Casing plastic according to UL94 V-0, light grey Dimensions 107 x 35 x 79 mm (87 mm with universal mounting bracket) Weight approx. 110 g Fitting position variable Operating temperature -40 to +80 °C (-40 to +176 °F) Storage temperature -40 to +85 °C (-40 to +185 °F) Operating/Storage humidity max. 90 % RH (non-condensing) Operating altitude ≤ 4,000 m above sea level Protection type/Protection class IP40 / III (SELV) Certificates EC 61010-1 UL and VDE up-comming 1 STEGO sensors SEN 073 must be ordered separately. The SHC 071 sensor hub enables up to four digital STEGO SEN 073 sensors to be integrated into IO-Link. Thus, up to eight measured values can be made available on one IO-Link port. Conventional IO-Link-capable sensors, on the other hand, will occupy one IO-Link port each on the IO-Link master. The slot assignment of the sensors on the SHC 071 sensor hub is freely selectable. The sensors SEN 073 can only be operated with the sensor hub SHC 071. Detailed information on the STEGO sensors SEN 073 for the sensor hub SHC 071 is provided on the following pages. > Digital IO-Link Interface > Small dimensions > Easy DIN rail and screw mounting > M12 plug-in connector > For 1 to 4 digital STEGO sensors > Quick connection of sensors via connectors > 4 sensor types Art. No. Interface Operating voltage Power consumption max. 07100.2-00 IO-Link (digital, specified acc. to version 1.1) DC 24 V (DC 18-30 V) 0.5 W Universal mounting bracket for DIN rail and screw mounting Example of connection IO-Link Master Sensors SEN 073 TECHNICAL DATASHEET www.stego-connect.com
DIGITAL PLUG & CONNECT SENSORS SEN 073 FOR SENSOR HUB SHC 071 The sensors for the SHC 071 Sensor Hub must be ordered separately. The digital sensors listed below are the current range of Plug & Connect compatible components for the Sensor Hub. All these sensors are pre-calibrated and thus immediately ready for use; individual calibration effort is not required. Due to their small dimensions and customizable cable lengths, they can be flexibly positioned and easily mounted. A mounting clip is included in the scope of delivery for each sensor. Art. No. Sensor Connection Measuring range 1 Measuring range 2 Weight (approx.) 07300.1-00 Temperature + rel. Humidity cable with connector, shielded, 1.0 m -40 to +80 °C (-40 to +176 °F) ±0.2 K 0 to 100 % RH ±2 % 40 g 07300.1-01 Temperature + rel. Humidity cable with connector, shielded, 2.0 m -40 to +80 °C (-40 to +176 °F) ±0.2 K 0 to 100 % RH ±2 % 70 g TECHNICAL DATA Mounting clip for 35 mm DIN rail, EN 60715 and screw mounting (M4) Casing plastic according to UL94 V-0, black Dimensions/Weight 59 x 12 x 13 mm Fitting position variable Response time T63 temperature: < 1,5 min, humidity: < 7 s Operating/Storage temperature -40 to +85 °C (-40 to +185 °F) Operating/Storage humidity 100 % RH / max. 90 % RH (non-condensing) Operating altitude ≤ 4,000 m above sea level Protection type IP20 Art. No. Sensor Operating/Storage temperature Measuring range 1 Measuring range 2 Response time T63 07300.0-00 Temperature + relative Humidity 0 to 100 % RH ±2 % 0 to 100 % rF ± 2 % temperature: < 2 min, humidity: < 20 s 07301.0-00 Absolute atmospheric pressure + temperature 300 to 1100 hPa -40 to +70 °C (-40 to +158 °F) absolute atmospheric pressure: < 5 s, temperature: < 2,5 min 07303.0-00 Air quality + temperature VOC-Index: 0 - 500 -10 to +50 °C air quality: < 10 s temperature: < 2,5 min TECHNICAL DATA Mounting incl. mounting clip for screw mounting, Ø 3 mm, see photo Casing stainless steel Dimensions/Weight 33.5 x Ø 20 mm / approx. 25 g Fitting position variable Connection M12 plug IEC 61076-2-101, 4-pin, A-coded Operating/Storage humidity 100 % RH / max. 90 % RH (non-condensing) Operating altitude ≤ 4,000 m above sea level Protection type IP64 Note Max. two of the four ports can be assigned with VOC sensors Art. No. Sensor Connection Measuring range Relative accuracy Response time T63 07302.0-00 Visible light M12 plug IEC 61076-2-101, 4-pin, A-coded 0,01 to 83.865 lx 0,2 % < 7 s TECHNICAL DATA Mounting incl. mounting clip for screw mounting, Ø 3 mm, see photo Casing stainless steel Dimensions/Weight 33.5 x Ø 20 mm / approx. 25 g Fitting position variable Operating/Storage temperature -40 to +85 °C (-40 to +185 °F) Operating/Storage humidity 100 % RH / max. 90 % RH (non-condensing) Operating altitude ≤ 4,000 m above sea level Note IP65 Photo: Mounting clip for screw mounting , Ø 3 mm (included) TECHNICAL DATASHEET www.stego-connect.com
Art. No. Length Connection 244445 2,0 m fully assembled with female M12 plug IEC 61076-2-101, 4-pin, A-coded, shielded 244446 5,0 m for self-assembly, incl. female M12 plug IEC 61076-2-101, 4-pin, A-coded, shielded 244447 20,0 m for self-assembly, incl. female M12 plug IEC 61076-2-101, 4-pin, A-coded, shielded CABLE These cables are required to connect the IO-Link sensor hub SHC 071 and its digital plug & connect sensors of the series SEN 073. The cables are not included in the scope of delivery of the sensors. The sensor cable with plug connection is locking and shielded. Image: customizable lenghts - Art. No. 244446 and Art. No. 244447 Image: standard cable - Art. No. 244445 CONNECTION EXAMPLE The illustration shows the IO-Link Sensor Hub SHC 071 with different sensors and connection cables (from top down): (1) Cable with connector and female M12 plug in 2.0 m length (Art. No. 244445) (5) Temperature+Humidity Sensor SEN 073, IP20, in 1.0 m or 2.0 m cable length with connector TECHNICAL DATASHEET www.stego-connect.com