https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 1 / 7 Disconnect terminal block - URKN - 0701011 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Disconnect terminal block, Connection method: Screw connection, Cross section: 0.5 mm² - 16 mm², AWG: 20 - 6, Width: 10.2 mm, Color: gray, Mounting type: NS 35/7,5, NS 35/15, NS 32 Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 23.6 g Custom tariff number 85369010 Country of origin Germany Technical data General Number of levels 1 Number of connections 2 Color gray Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 6 kV Pollution degree 3 Overvoltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-1 Nominal current IN 70 A Maximum load current 70 A (with 16 mm² conductor cross section) Nominal voltage UN 690 V Open side panel ja Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection guaranteed
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 2 / 7 Disconnect terminal block - URKN - 0701011 Technical data General Finger protection guaranteed Result of surge voltage test Test passed Surge voltage test setpoint 9.8 kV Ergebnis der Prüfung der mechanischen Festigkeit von Klemmstellen (5maliger Leiteranschluss) Test passed Result of bending test Test passed Bending test rotation speed 10 rpm Bending test turns 135 Bending test conductor cross section/weight 0.5 mm² / 0.3 kg 10 mm² / 2 kg 16 mm² / 2.9 kg Tensile test result Test passed Conductor cross section tensile test 0.5 mm² Tractive force setpoint 40 N Conductor cross section tensile test 10 mm² Tractive force setpoint 180 N Conductor cross section tensile test 16 mm² Tractive force setpoint 200 N Ergebnis Festsitz auf der Befestigungsauflage Test passed Tight fit on carrier NS 32/NS 35 Setpoint 5 N Ergebnis Spannungsfallprüfung Test passed Temperature-rise test Test passed Dimensions Length 43 mm Width 10.2 mm Height NS 35/7,5 50.5 mm Height NS 35/15 58 mm Height NS 32 55.5 mm Connection data Conductor cross section solid min. 0.5 mm² Conductor cross section solid max. 16 mm² Conductor cross section flexible min. 0.5 mm² Conductor cross section flexible max. 10 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 6 Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 3 / 7 Disconnect terminal block - URKN - 0701011 Technical data Connection data Conductor cross section flexible, with ferrule without plastic sleeve max. 16 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 10 mm² 2 conductors with same cross section, solid min. 0.5 mm² 2 conductors with same cross section, solid max. 10 mm² 2 conductors with same cross section, stranded min. 0.5 mm² 2 conductors with same cross section, stranded max. 10 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 6 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 6 mm² Connection method Screw connection Stripping length 14 mm Screw thread M4 Tightening torque, min 1.5 Nm Tightening torque max 1.8 Nm Standards and Regulations Connection in acc. with standard IEC 60947-7-1 Flammability rating according to UL 94 V0 Classifications eCl@ss eCl@ss 4.0 27141126 eCl@ss 4.1 27141126 eCl@ss 5.0 27141127 eCl@ss 5.1 27141127 eCl@ss 6.0 27141127 eCl@ss 7.0 27141127 eCl@ss 8.0 27141120 eCl@ss 9.0 27141120 ETIM ETIM 2.0 EC000902
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 4 / 7 Disconnect terminal block - URKN - 0701011 Classifications ETIM ETIM 3.0 EC000902 ETIM 4.0 EC000902 ETIM 5.0 EC000897 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410 UNSPSC 12.01 39121410 UNSPSC 13.2 39121410 Approvals Approvals Approvals RS / EAC Ex Approvals Approvals submitted Approval details RS EAC Drawings
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 5 / 7 Disconnect terminal block - URKN - 0701011 Schematic diagram Transducer test set with outlet Schematic diagram Current transformer test circuit with movable links
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 6 / 7 Disconnect terminal block - URKN - 0701011 Circuit diagram 1 = cover 2 = fixed bridge 3 = insertion bridge 4 = isolator bridge bar 5 = switch bar for 2 terminal blocks 6 = separating plate 7 = partition plate 8 = test plug socket 9 = Zack marker strip 10 = screwdriver
https://www.phoenixcontact.com/us/products/0701011 12/09/2015 Page 7 / 7 Disconnect terminal block - URKN - 0701011 Schematic diagram Simple current transformer test circuit a = normal operation b = measured value testing c = transformer short-circuit d = relay testing Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com