0330 BURKERT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 24
Technical content
Visit product website DATA SHEET Type 1087 Timer, form A according to DIN EN 175301 803 Type 2518 Cable plug, form A according to DIN EN 175301 803 Type 2509 Cable plug, form A according to DIN EN 175301 803 Standard | US | en | 2024-03-25 | 24 Direct-acting 2/2 or 3/2-way pivoted armature valve
- Direct-acting, media-separated valve up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed solenoid system Service-friendly, robust manual override Explosion-proof variants The 0330 valve is a direct-acting, media-separated pivoted armature valve. It is available as a 2/2 and 3/2-way variant. As a 3/2-way variant, it can be used as a distributor or mixing valve. Various diaphragm materials and circuit functions are available depending on the actual application. Brass, stainless steel, PEEK and polypropylene bodies are offered. The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a dia- phragm, the valve is especially suitable for critical media such as aggressive acids and lyes. The 0330 is equipped with manual override for start-up and testing. To reduce energy demands, all the coils can be delivered with electronic power reduc- tion or as an impulse variant. The switching status can be indicated via position feedback as a binary or NAMUR signal. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type 0330 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 24Visit product website Table of contents 1. General technical data 4 Circuit functions Approvals and conformities 3.2. Conformity 3.3. Standards 3.4. Explosion protection 3.5. North America (USA/Canada) 3.6. Others DNV GL classification 4. Materials 8 4.2. Material specifications 5. Dimensions 9 Metal body Plastic body Cable version 5.2. Explosion-proof version Terminal box version Cable version 6. Device/Process connections 14 6.2. Pin assignment explosion-proof version 7. Performance specifications 15 Standard version Explosion-proof version Use in other circuit functions 8. Product accessories 17 8.2. Accessories explosion-proof version 8.3. Cable glands for ATEX/IECEx terminal box 8.4. Special tool to turn the terminal box
3 | 24Visit product website 9. Ordering information 19 9.2. Bürkert product filter 9.3. Bürkert Product Enquiry Form 9.4. Ordering chart UL Recognized (UR) and CSA approval Coil UL Listed (cULus) for hazardous locations, Class I, Division 2 9.5. Ordering chart accessories Cable plug Type 2518, form A according to DIN EN 175301 803 Cable plug Type 2509, form A according to DIN EN 175301 803 Cable glands for ATEX/IECEX terminal box Mounting plate complete for DIN rail mounting Locking ring
4 | 24Visit product website 1. General technical data Product properties Dimensions Further information can be found in chapter “5. Dimensions” on page 9 Material Seal EPDM FKM FFKM NBR Body Brass Stainless steel 1.4401/316 PP (Polypropylene) PVDF (on request) PEEK Material resistance Further information can be found in chapter “4.1. Bürkert resistApp” on page 8 Weight Standard version Metal body: 0.99 lb Plastic body: 0.66 lb Explosion-proof version Metal body: 1.65 lb Plastic body: 1.32 lb Orifice DN 2…DN Circuit function Further information can be found in chapter “2. Circuit functions” on page 5 Thermal insulation class of solenoid coil Epoxy coil class H Performance data Duty cycle With brass, stainless steel and PEEK 100 With PP and PVDF 40 % duty cycle (60 % intermittent operation) in 30 min for 8 W version 100 % duty cycle for 5 W version Switching frequency (explosion-proof version) Medium temperature up to + 158 °F: max. 20/min Medium temperature up to + 194 °F: max. 5/min Switching time 1.) standard version Frequency AC Opening: 8…15 ms Closing: 8…15 ms Frequency DC Opening: 10…20 ms Closing: 10…20 ms Switching time 1.) explosion-proof version Orifice DN 2…DN
4 Opening: 30
Closing: 40 ms Electrical data Power consumption standard Frequency AC Inrush: 30 VA Hold: 15 VA Hold: 8 W Frequency DC Cold: 11 W Warm: 8 W Power consumption Impulse (inrush winding) Frequency AC Hold: 20 VA Hold: 11 W Frequency DC Cold: 11 W Warm: 8 W Power consumption explosion-proof version Frequency AC/DC Inrush: 40 W Hold: 3 W Voltage Standard version 24 V/50 Hz, 110 V/50 Hz, 230 V/50 Hz, 120 V/60 Hz, 240 V/60 Hz, 12 V/DC, 24 V/DC (further voltages on request) Explosion-proof version 24 V, 230 V (further voltages on request) Voltage tolerance ±
5 | 24Visit product website Medium data Operating medium With NBR Neutral medium such as compressed air, town gas, water, hydraulic oil, oils and greases without additives, oxygen With EPDM Alkalis, acids to medium concentrations, alkaline washing and bleaching lyes With FKM Oxydizing acids and substances, hot oils with additives, salt solutions, waste gases, oxygen With FFKM Aggressive mediums, hot air, hot oils All Materials Further information can be found in chapter “4.1. Bürkert resistApp” on page 8 Medium temperature With body material brass, stainless steel or PEEK NBR: 32 °F…+ 176 EPDM: - °F…+ 194 FKM: 32 °F…+ 194 FFKM: + °F…+ 194 With body material PP NBR: 32 °F…+ 176 EPDM: - °F…+ 176 FKM: 32 °F…+ 176 FFKM: + °F…+ 176 Viscosity Max. 37 cSt Process/Port connection & communication Electrical connection Standard version • Plug contacts according to DIN EN 175 301 803 form A for cable plug Type 2518 Further information can be found in chapter “Cable plug Type 2518, form A according to DIN EN 175301 803” on page 23 Plug contacts according to DIN EN 175 301 803 form A for cable plug Type 2509 (Also available with moulded cable on request.) Further information can be found in chapter “Cable plug Type 2509, form A according to DIN EN 175301 803” on page 23 Explosion-proof version Moulded cable Terminal box without safety fuse (Information about ACP016 see operating manual.) Port connection G ¼, NPT ¼, (RC ¼ and G ⅛ on request, G ⅛ not possible for PP and PEEK) Approvals and conformities Degree of protection Standard version IP65 with cable plug Explosion-proof version IP65 Explosion protection Further information can be found in chapter “3.4. Explosion protection” on page 6 North America (USA/Canada) Further information can be found in chapter “3.5. North America (USA/Canada)” on page 7 Others Further information can be found in chapter “3.6. Others” on page 7 Environment and installation Installation position As required, preferably with actuator upright Ambient temperature Standard version Max. + 131 Explosion-proof version Max. + 131 1.) Measurement at + 68 °F, 87 psi at the valve outlet, opening: pressure build-up 0…90 %, closing: pressure reduction 100…10 % 2. Circuit functions Symbol Description 2 (A) 1 (P) Circuit function A (CF A) 2/2-way solenoid valve Direct-acting Normally closed 2 (B) 1 (P) Circuit function B (CF B) 2/2-way solenoid valve Direct-acting Normally open 2(A) 1(P) 3(R) Circuit function C (CF C) 3/2-way solenoid valve Direct-acting Normally closed
6 | 24Visit product website Symbol Description 2(B) 1(P) 3(R) Circuit function D (CF D) 3/2-way solenoid valve Direct-acting Normally open 2(A) 1(P1) 3(P2) Circuit function E (CF E) 3/2-way mixing valve (solenoid valve) 4(A) 2(B) 1(P) Circuit function F (CF F) 3/2-way distribution valve (solenoid valve) Direct-acting 2(A) 1(P) 3(R) Circuit function T (CF T) 3/2-way solenoid valve Direct-acting Flow direction optional Normally closed 3. Approvals and conformities 3.1. General notes
- The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below mentioned approvals or conformities. 3.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. 3.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 3.4. Explosion protection Approval Description Optional: Explosion protection according to category 2 (zone 1/21) Ex marking of the components according to the following table: Coil Type ACP016 Coils with cable outlet Coils with terminal box ATEX: EPS 16 ATEX 1 111 X II 2 G Ex mb IIC T4 Gb II 2 D Ex mb IIIC T130 °C Db IECEx: IECEx EPS 16.0049X Ex mb IIC T4 Gb Ex mb IIIC T130 °C Db ATEX: PTB 15 ATEX 1011 U II 2G Ex eb mb IIC T4 Gb II 2D EX mb tb IIIC T130 IECEx: IECEx PTB 15.0037 U II eb mb IIC T4 Gb II mb tb IIIC T130 °C Db
7 | 24Visit product website 3.5. North America (USA/Canada) Approval Description Optional (valid for valves): UL Listed for the USA The valves are UL Listed for the USA according to: UL 429 (electrically operated valves) and UL 429A (Electrically Operated Valves for Fire Protection Service) SOLENOID FOR USE IN HAZARDOUS LOCATIONS E504714 Optional (valid for coils): UL Hazardous Locations – Explosion Protection UL Listed for Hazardous Locations for USA and Canada Class I, Zone 1 Class I, Division 2, Group A, B, C and D Class II + III, Division 2, Group F and G Optional (valid for valves): UL Recognized for the USA The valves are UL Recognized for the USA according to: UL 429 (electrically operated valves) and UL 429A (Electrically Operated Valves for Fire Protection Service) Optional (valid for valves): CSA for Canada The valves are CSA approved for Canada according to: CSA 139 (electrically operated valves) Optional (valid for coils): FM (Factory Mutual) – Explosion Protection FM for Hazardous Locations for USA and Canada Class I, Zone 1 Class I, Division 1, Groups A, B, C and D Class II + III, Division 1, Groups E, F and G 3.6. Others DNV GL classification Approval Description DNV GL classification – Ships, offshore units, and high speed and light craft The products are accepted for installation on all vessels classed by DNV GL.
8 | 24Visit product website 4. Materials 4.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check 4.2. Material specifications No. Element Material
1 Coil Epoxy
2 Diaphragm EPDM, FKM, FFKM, NBR
3 O-ring EPDM, FKM, FFKM, NBR
4 Seat Brass
Stainless steel (1.4401/316) PP (Polypropylene) PEEK
5 Valve body Brass
Stainless steel (1.4401/316) PP (Polypropylene) PEEK
9 | 24Visit product website 5. Dimensions 5.1. Standard version General notes: The dimensions D1 and L1 apply to G-threads. The dimensions D2 and L2 apply to NPT-threads. The device can be attached via the existing holes on the bottom side. The hole pattern is 38x24/1.5x0.94. For metal bodies, use M4 screws. For plastic bodies, use either self-tapping screws or a body with metric thread inserts (variable codes ACxx or ADxx). The screw-in depth must be observed. Refer to operating instructions Type 0330 The dimensions of the cable plug Type 2518 can be found in chapter “Cable plug Type 2518, form A according to DIN EN 175301 803” on page 23 The dimensions of the cable plug Type 2509 can be found in chapter “Cable plug Type 2509, form A according to DIN EN 175301 803” on page 23 Metal body Note: Dimensions in mm [inch] For metal bodies, the minimum thread length at the middle connection is 7.5 mm [0.295 inch] Screw-in depth of G ¼ connection threads: When using pipe fittings, select versions with G ⅛, as the screw-in depth with G ¼ is not sufficient. See the general notes at the beginning of chapter “5.1. Standard version” on page 9 24 0,94 38 1,5 46 1,81 34 1,34 12 0,479 0,35 18 0,71 71 2,8 9 0,35 L D D1 L1 D2 L2 [mm] [inch] [mm] [inch] G ⅛ 9 0.354 – – – G ¼ 9 0.354 NPT ¼ 7.5 0.295
10 | 24Visit product website Plastic body Note: Dimensions in mm [inch] See the general notes at the beginning of chapter “5.1. Standard version” on page 9 PP (Polypropylene) PEEK 56 2,2 75 2,95 22 0,87 D L 24 0,94 38 1,5 46 1,81 4 0,16 34 1,34 12 0,47 9 0,35 13 0,51 12 0,47 75 2,95 13 0,51 22 0,87 9 0,35 55,5 2,19 D L 24 0,94 38 1,5 46 1,81 34 1,34 3 0,12
11 | 24Visit product website Cable version Note: Dimensions in mm [inch] See the general notes at the beginning of chapter “5.1. Standard version” on page 9 7,8 0,31 26 1,02 46 1,81 9 0,35 77,5 3,05 40 1,57 24 0,94 38 1,5 34 1,34
12 | 24Visit product website 5.2. Explosion-proof version Terminal box version Note: Dimensions in mm [inch] The dimensions D1 and L1 apply to G-threads. The dimensions D2 and L2 apply to NPT-threads. 9 0,35 46 1,81 18 0,7154,8 2,16 54 2,13 9 0,35 L D 36,6 1,44 Pivoting radius cover R84 Cable gland M20x1,5 / NPT 1/2-14 38 1,5 24 0,94 98 3,86 130 5,12 34 1,34 32 1,26 45° 100,3 3,92 95,3 3,75 D 7,5 0,3 64,6 2,54 74,4 2,9 D1 L1 D2 L2 [mm] [inch] [mm] [inch] G ⅛ 9 0.354 – – – G ¼ 9 0.354 NPT ¼ 7.5 0.295
13 | 24Visit product website Cable version Note: Dimensions in mm [inch] 24 0,94 38 1,5 34 1,34 6,2 0,24 Cable length according to order 9 0,35 40,5 1,59 78,5 3,09
14 | 24Visit product website 6. Device/Process connections 6.1. Pin assignment standard version Note: The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. In the table, compare the respective pin assignment with the corresponding circuit function. Circuit function Connection Connection Connection 2-way 3-way A P A – 2 1 1 B B P – C P A R D R B P E P1 A P2 F A P B T NC I N/OUT NO 6.2. Pin assignment explosion-proof version Note: The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. In the table, compare the respective pin assignment with the corresponding circuit function. Circuit function Connection Connection Connection 2-way 3-way A P A – 2 1 1 B B P – C P A R D R B P E P1 A P2 F A P B T NC I N/OUT NO
15 | 24Visit product website 7. Performance specifications 7.1. Pressure range and flow rate Standard version Note: Refer to “Use in other circuit functions” on page 16 for more information about use in other circuit function. Circuit function DN CV value water 1.) Pressure range 2.) (MWAP 9.)) DC AC (50 or 60 Hz) Standard 3.) Vacuum 4.) Impulse 5.) [gal/min] [gal/min] [psi] [psi] [psi] Metal body A / B / C / D / F 2 0.09 0.13 0…232 3 0.16 0.21 0…145 - 14…87 0…145 4 0.20 0.27 0…73 - 14…44 0…73 5 0.34 0.34 0…36 - 14…15 0…36 E 2 0.09 0.13 0…145 - 14…116 0…145 3 0.16 0.21 0…87 - 14…73 0…87 4 0.20 0.27 0…44 - 14…36 0…44 5 0.34 0.34 0…22 - 14…15 0…15 T 2 0.09 0.13 0…174 - 14…116 0…145 3 0.16 0.21 0…116 - 14…73 0…87 4 0.20 0.27 0…58 - 14…36 0…73 5 0.34 0.34 0…36 - 14…15 – Circuit function DN CV value water 7.) Pressure range 2.) (MWAP 9.)) Standard 3.) AC [50 or 60 Hz] Standard 3.) DC Vacuum 4.) Impulse 5.) [gal/min] [psi] [psi] [psi] [psi] Plastic body A / B / C / D / F 2 0.15 0…232 3 0.29 0…145 0…116 - 14…87 0…116 4 0.35 0…73 0…58 - 14…44 0…58 5 0.46 0…65 0…44 - 14…15 0…44 E / T 2 0.15 0…145 0…101 - 14…101 0…101 3 0.29 0…87 0…58 - 14…73 0…58 4 0.35 0…44 0…29 - 14…36 0…29 5 0.46 0…29 0…15 - 14…7 0…15 1.) For frequency 56, the CV values of the DC version apply 2.) Pressure data: overpressure to atmospheric pressure (deviating pressure range for 5 W version) 3.) Heat output 8 W 4.) Vacuum possible for all seal materials 5.) Starting power 11 W 6.) The maximum medium pressure is 174 psi for seal material FKM and FFKM. 7.) The CV value at DC frequency is reduced by up to 10 % to guarantee the function. 8.) The maximum operating pressure is 145 psi for industry material PVDF. 9.) Maximum allowable working pressure
16 | 24Visit product website Explosion-proof version Note: Refer to “Use in other circuit functions” on page 16 for more information about use in other circuit function. Circuit function DN CV value water Pressure range 1.) 2.) (MAWP 4.)) Standard Vacuum [gal/min] [psi] [psi] Metal body A / B / C / D / F 2.0 0.13 0…232 - 14…145 3.0 0.21 0…145 - 14…87 4.0 0.27 0…73 - 14…44 5.0 0.34 0…58 - 14…36 E 2.0 0.15 0…145 - 14…116 3.0 0.21 0…87 - 14…73 4.0 0.27 0…51 - 14…36 5.0 0.34 0…44 - 14…29 T 2.0 0.15 0…145 - 14…116 3.0 0.21 0…87 - 14…73 Circuit function DN CV value water Pressure range 1.) 2.) (MAWP 4.)) Standard Vacuum [gal/min] [psi] [psi] Plastic body A / B / C / D / F 2.0 0.15 0…232 3.) - 14…145 3.0 0.29 0…145 - 14…87 4.0 0.35 0…73 - 14…44 5.0 0.46 0…65 - 14…15 E / T 2.0 0.15 0…145 - 14…101 3.0 0.29 0…87 - 14…73 4.0 0.35 0…44 - 14…36 1.) Devices with FKM and/or FFKM diaphragms are reduced to a maximum pressure of 174 psi. 2.) Pressure data: overpressure to atmospheric pressure 3.) The maximum operating pressure is 145 psi. for industry material PVDF. 4.) Maximum allowable working pressure Use in other circuit functions The compression springs installed in the valves differ depending on the circuit function. When used in other circuit functions, the permissi- ble operating pressure changes according to the following table. Note: The following table applies to both the standard version and the explosion-proof version. Circuit function Max. operating pressure [psi] when using the valve in a new circuit function Orifice DN
2 Orifice
3 Orifice
A 1.) B 1.) C D E F A B C D E F A B C D E F Metal body (8 W respectively 11 C 232 22 232 22 22 232 145 15 145 15 15 145 72.5 12 72.5 12 12 72.5 D 58 232 65 232 58 58 36 145 36 145 29 44 29 73 29 73 29 29 T 116 116 145 145 145 116 87 87 87 87 87 87 44 44 44 44 44 44 Plastic body (8 W respectively 11 C 232 22 232 22 22 232 145 15 145 15 15 145 72.5 12 72.5 12 12 72.5 D 58 232 65 232 58 458 36 145 36 145 29 44 29 72.5 29 73 29 29 F 232 22 145 22 22 232 87 15 87 15 15 145 58 15 58 15 15 72.5 1.) For circuit function A and B the valve must be connected according to the pin assignment of 3/2-way valve.
17 | 24Visit product website 8. Product accessories 8.1. Accessories standard version Option Variable Code Description Impulse version CF02 Bistable magnetic system with inrush and drop-off coil; continuous operation or operation with short current pulses (min. 150 ms) possible Oxygen versions NL02 Suitable for applications with oxygen (non-metal materials that are in contact with the medium, are tested and approved according to BAM) Increased purity requirements, e.g. oil, grease and silicone-free NL50/ NL05 Wetted parts are specially cleaned and packaged in accordance with the valves Increased tightness requirements PCxx Standard units are tested at 10 - 2 mbar x l/sec; feasible up to 10 - 6 mbar LF03 See Type 1060 . Function as opener, closer or toggle switch depending on the connection (no IP65 achievable) High-power electronics CZ05 Inrush power 60 W, nominal holding current 3 W; with plastic versions 100 duty cycle is now feasible Vacuum version NA02 Suitable for vacuums up to - psi Increased purity and tightness requirements NA03 Wetted parts are specially cleaned and leak tested to 10 - 4 mbar x l/sec Increased purity and tightness requirements and vacuum version NA01 Wetted parts are specially cleaned and leak tested up to 10 - 4 mbar x l/sec and suited for vacuum up to - 14 psi Coil with reduced power (5 W) – Devices have lower pressure range; with plastic versions 100 % duty cycle is now feasible Cable plug JHxx/ JGxx/ JFxx Cable plug is part of the delivery. Cable plug versions (according to DIN EN 175301 803 form A), see data sheet Type 2518 and Type 2509 Approvals PD01 CSA General Purpose valve PD02 UR (UL Recognized)/CSA approval PD07 DNV-GL (formerly Germanischer Lloyd) PR05 cFMus approved coil Class I, Division 1, Groups A, B, C and D - T4 Class II, Division 1, Groups E, F and G - T4 Class III, Division 1 - T4 Class I, Zone 1, AEx mb IIC T4 Gb, Zone 21 AEx mb IIIC T130 °C Db Ex mb IIC T4 Gb; Ex mb IIIC T130 °C Db PE95 UL (UL Listed) approval PU15 UL Listed for Hazardous Locations for USA and Canada, Class I, Zone 1, AEx eb mb IIC T4; Zone 21, AEx mb tb IIIC T130 °C / Class I, Div 2, Group A,B,C,D; Class II+III, Div 2, Group F,G PX41 EPS 16 ATEX 1111 X/IECEx EPS 16.0049X, 2G T4 IIC/2D T130 °C IIIC, Tamb - °C…+ °C, single and block mounting Possible conformities (depending on the assembly) – EAC, drinking water, FDA 8.2. Accessories explosion-proof version Option Variable Code Description Oxygen versions NL02 Suitable for applications with oxygen (non-metal materials that are in contact with the medium, are tested and approved according to BAM) Increased purity requirements e.g. oil, grease and silicone-free NL50/ NL05 Wetted parts are specially cleaned and packaged in accordance with the valves Increased hermetic requirements PCxx Standard units are tested at 10 - 2 mbar x l / sec; feasible up to 10 - 6 mbar Vacuum version NA02 Suitable for vacuums up to - bar Increased purity and hermetic requirements NA03 Wetted parts are specially cleaned and leak tested to 10 - 4 mbar x l/sec Increased purity and hermetic requirements and vacuum version NA01 Wetted parts are specially cleaned and leak tested up to 10 - 4 mbar x l/sec and suited for vacuum up to - 14 bar manual override
18 | 24Visit product website 8.3. Cable glands for ATEX/IECEx terminal box Note: A polyamide cable gland is included in the scope of delivery. A nickel-plated brass version can be ordered for a surcharge, see “Cable plug Type 2509, form A according to DIN EN 175301 803” on page Description Ex approvals Dimensions Certification Identification Ex cable gland, Nickel-plated brass, 6…13 mm PTB 04 ATEX 1112 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 29…37 mm L 6 mm D 20 mm SW 24 mm E 27 mm Ex cable gland, Polyamide, 7…13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 36…45 mm L 10 mm D 20 mm SW 24 mm E 28 mm 8.4. Special tool to turn the terminal box Note: This special tool is not supplied with the valve, see “Cable glands for ATEX/IECEX terminal box” on page 23 Description Components of the set Set SC02-AC10
- Special wrench Service manual
19 | 24Visit product website 9. Ordering information 9.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 9.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 9.3. Bürkert Product Enquiry Form Bürkert Product Enquiry Form – Your enquiry quickly and compactly Would you like to make a specific product enquiry based on your technical requirements? Use our Product Enquiry Form for this purpose. There you will find all the relevant informa- tion for your Bürkert contact. This will enable us to provide you with the best possible advice. Fill out the form now
20 | 24Visit product website 9.4. Ordering chart UL Recognized (UR) and CSA approval Note: All devices with connection thread NPT ¼ and manual override. Other versions are available on request. Articles with reduced delivery time Circuit function Orifice Body or seat material Seal material Article no. 024/DC 024/60 120/60 240/60 [mm] [V/Hz] [V/Hz] [V/Hz] [V/Hz] CF A 1.) 2/2-way solenoid valve Direct-acting Normally closed 2 (A) 1 (P)
3.0 Brass FKM 461284
468642 460216 o. r. Stainless steel FKM 459292 o. r. 459291 o. r.
4.0 Brass FKM 464433
o. r. 464435 o. r. Stainless steel FKM 464432 o. r. 464434 o. r. PP FKM 20004726 EPDM 20063459 CF B 1.) 2/2-way solenoid valve Direct-acting Normally open 2 (B) 1 (P)
3.0 Brass FKM 458947 458948 458949 458950
Stainless steel FKM 458959 o. r. 458961 o. r.
4.0 Brass FKM 458951
o. r. o. r. 458954 Stainless steel FKM 458963 458964 458965 o. r. CF C 3/2-way solenoid valve Direct-acting Normally closed 2(A) 1(P) 3(R) Stainless steel FKM 451711 o. r. 450298 451715 Stainless steel FKM 466195 o. r. 451721 o. r.
21 | 24Visit product website Circuit function Orifice Body or seat material Seal material Article no. 024/DC 024/60 120/60 240/60 [mm] [V/Hz] [V/Hz] [V/Hz] [V/Hz] CF D 3/2-way solenoid valve Direct-acting Normally open 2(B) 1(P) 3(R) CF E 3/2-way mixing valve (solenoid valve) 2(A) 1(P1) 3(P2) CF F 3/2-way distribution valve (solenoid valve) Direct-acting 4(A) 2(B) 1(P) CF T 3/2-way solenoid valve Direct-acting Flow direction optional Normally closed 2(A) 1(P) 3(R) o. r. = on request 1.) The listed article numbers and circuit functions have a body with straight pass.
22 | 24Visit product website Coil UL Listed (cULus) for hazardous locations, Class I, Division 2 Note: All devices with connection thread NPT ¼ and manual override. Other versions are available on request. Circuit function Orifice Body or seat material Seal material Electrical connection Article no. 024 AC/DC 120/60 240/60 [mm] [V/Hz] [V/Hz] [V/Hz] CF A 1.) 2/2-way solenoid valve Direct-acting Normally closed 2 (A) 1 (P) Stainless steel FKM Terminal box 384939 20036806 o. r. CF C 3/2-way solenoid valve Direct-acting Normally closed 2(A) 1(P) 3(R) CF E 3/2-way mixing valve (solenoid valve) 2(A) 1(P1) 3(P2) Cable 387628 o. r. o. r. CF F 3/2-way distribution valve (solenoid valve) Direct-acting 4(A) 2(B) 1(P) o. r. = on request 1.) The listed article numbers and circuit functions have a body with straight pass.
23 | 24Visit product website 9.5. Ordering chart accessories Cable plug Type 2518, form A according to DIN EN 175301 - 803 Note: Dimensions in mm For further versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V AC/DC 314802 With LED (AC/DC) 12…24 V AC/DC 314812 With LED and varistor (AC/DC) 12…24 V AC/DC 314820 With rectifier, LED and varistor 12…24 V AC/DC 314816 Without circuitry (AC/DC) with silicone seal for higher ambient temperature, e.g. steam version (NA07) 0…250 V AC/DC 361687 Cable plug Type 2509, form A according to DIN EN 175301 803 Note: Dimensions in mm Without circuitry (standard) Refer to data sheet Type 2509 for more information about the cable plug. Cable plug Dimensions Version Voltage Article no. 28.4 32.5 58.85 32.5 4.3 NPT ½ Ø 26 2 1 Without circuitry 0…250 V AC/DC 137943 Cable glands for ATEX/IECEX terminal box Note: A cable gland in polyamide version is included in the delivery. A nickel-plated brass version can be ordered at surcharge. Refer to “8.3. Cable glands for ATEX/IECEx terminal box” on page 18 for more information about Ex cable glands. Refer to “8.4. Special tool to turn the terminal box” on page 18 for more information about special wrench. Description Article no. Ex cable gland, nickel-plated brass, 6…13 mm 1.) 773278 Ex cable gland, polyamide, 7…13 mm 1.) 773277 Set SC02-AC10: special wrench 2.) incl. service manual 293488 1.) Cable diameter 2.) Not included in the scope of delivery of the valve
24 | 24Visit product website Mounting plate complete for DIN rail mounting Description Article no. Mounting plate cpl. Valve 013253 Locking ring Description Article no. Locking ring to prevent inadvertent manual actuation 013372