https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 1 / 6 Test disconnect terminal block - URTK/S-BEN 10 - 0309109 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Test disconnect terminal block, with slide, connection method: Screw connection, cross section: 0.5 mm² - 16 mm² , AWG: 20 - 8, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray Your advantages Easy and clear testing in current transformer secondary circuits can be performed using the test disconnect terminal blocks of the URTK/S range On both sides of the disconnect point, the terminal block has a test socket which can also be used to switch across to neighboring terminal blocks Key Commercial Data Packing unit 50 pc GTIN GTIN 4017918155230 Technical data General Number of levels 1 Number of connections 2 Nominal cross section 10 mm² Color gray Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 6 kV Degree of pollution 3 Overvoltage category III Insulating material group I Maximum power dissipation for nominal condition 1.82 W Connection in acc. with standard IEC 60947-7-1 Nominal current IN 57 A
https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 2 / 6 Test disconnect terminal block - URTK/S-BEN 10 - 0309109 Technical data General Maximum load current 76 A (with 16 mm² conductor cross section) Nominal voltage UN 500 V Open side panel Yes Shock protection test specification IEC 60529:2001-02 Back of the hand protection guaranteed Finger protection guaranteed Result of surge voltage test Test passed Surge voltage test setpoint 7.3 kV Result of power-frequency withstand voltage test Test passed Power frequency withstand voltage setpoint 1.89 kV Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed Result of bending test Test passed Bending test rotation speed 10 rpm Bending test turns 135 Bending test conductor cross section/weight 0.5 mm² / 0.3 kg 10 mm² / 2 kg 16 mm² / 2.9 kg Tensile test result Test passed Conductor cross section tensile test 0.5 mm² Tractive force setpoint 20 N Conductor cross section tensile test 10 mm² Tractive force setpoint 90 N Conductor cross section tensile test 16 mm² Tractive force setpoint 100 N Result of tight fit on support Test passed Tight fit on carrier NS 32/NS 35 Setpoint 5 N Result of voltage-drop test Test passed Requirements, voltage drop ≤ 6,4 mV Temperature-rise test Test passed Short circuit stability result Test passed Conductor cross section short circuit testing 10 mm² Short-time current 1.2 kA Conductor cross section short circuit testing 16 mm² Short-time current 1.92 kA Result of thermal test Test passed Proof of thermal characteristics (needle flame) effective duration 30 s Relative insulation material temperature index (Elec., UL 746 B) 130 °C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 3 / 6 Test disconnect terminal block - URTK/S-BEN 10 - 0309109 Technical data General Static insulating material application in cold -60 °C Behavior in fire for rail vehicles (DIN 5510-2) Test passed Flame test method (DIN EN 60695-11-10) V0 Oxygen index (DIN EN ISO 4589-2) >32 % NF F16-101, NF F10-102 Class I 2 NF F16-101, NF F10-102 Class F 2 Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Smoke gas toxicity NFPA 130 (SMP 800C) passed Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Dimensions Length 61 mm Width 8.2 mm Height NS 35/7,5 58.5 mm Height NS 35/15 66 mm Height NS 32 63.5 mm Connection data Note Terminal point Conductor cross section solid min. 0.5 mm² Conductor cross section solid max. 16 mm² Conductor cross section flexible min. 0.5 mm² Conductor cross section flexible max. 10 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 6 Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm² 2 conductors with same cross section, solid min. 0.5 mm² 2 conductors with same cross section, solid max. 6 mm² 2 conductors with same cross section, stranded min. 0.5 mm² 2 conductors with same cross section, stranded max. 4 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 6 mm²
https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 4 / 6 Test disconnect terminal block - URTK/S-BEN 10 - 0309109 Technical data Connection data 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 4 mm² Cross section with insertion bridge, solid max. 10 mm² Cross section with insertion bridge, stranded max. 10 mm² Connection method Screw connection Stripping length 11 mm Screw thread M4 Tightening torque, min 1.5 Nm Tightening torque max 1.8 Nm Disconnect element M3 0.6 Nm 0.8 Nm Standards and Regulations Connection in acc. with standard CSA IEC 60947-7-1 Flammability rating according to UL 94 V0 Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Environmental Product Compliance Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Circuit diagram Approvals Approvals Approvals CSA / UL Recognized / cUL Recognized / EAC / cULus Recognized
https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 5 / 6 Test disconnect terminal block - URTK/S-BEN 10 - 0309109 Approvals Ex Approvals Approval details CSA http://www.csagroup.org/services-industries/product-listing/ 13631 Nominal voltage UN 600 V Nominal current IN 55 A mm²/AWG/kcmil 26-8 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425 Nominal voltage UN 600 V Nominal current IN 50 A mm²/AWG/kcmil 26-8 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425 Nominal voltage UN 600 V Nominal current IN 50 A mm²/AWG/kcmil 26-8 EAC EAC-Zulassung cULus Recognized
https://www.phoenixcontact.com/pi/products/0309109 09/26/2019 Page 6 / 6 Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8
32825 Blomberg
Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com