The high power 2651A SourceMeter SMU Instrument is specifically designed to characterize and test high power electronics. This SMU instrument can help you improve productivity in applications across the R&D, reliability, and production spectrums, including high brightness LEDs, power semiconductors, DC-DC converters, batteries, solar cells, and other high power materials, components, modules, and subassemblies. The 2651A offers a highly flexible, four-quadrant voltage and current source/load coupled with precision voltage and current meters. It can be used as a:

  • Semiconductor characterization instrument
  • V or I waveform generator
  • V or I pulse generator
  • Precision power supply
  • True current source
  • Digital multimeter (DCV, DCI, ohms, and power with 6½-digit resolution)
  • Precision electronic load Key Features
  • Source or sink: – 2,000 W of pulsed power (±40 V, ±50 A) – 200 W of DC power (±10 V @ ±20A, ±20 V @ ±10 A, ±40 V @ ±5 A)
  • Easily connect two units (in series or parallel) to create solutions up to ±100 A or ±80 V
  • 1 pA resolution enables precise measurement of very low leakage currents
  • 1 μs per point (1 MHz), 18-bit sampling, accurately characterizes transient behavior
  • 1% to 100% pulse duty cycle for pulse width modulated (PWM) drive schemes and device- specific drive stimulus
  • Combines a precision power supply, current source, DMM, arbitrary waveform generator, V or I pulse generator with measurement, electronic load, and trigger controller—all in one instrument 2651A 50 A, High Power System SourceMeter® SMU Instrument DATASHEET

+20 A +30 A +50 A –50 A –10 A +10 A +5 A –5 A –20 A –30 A 0 A +10 V–10 V +20 V–20 V 0 V +40 V–40 V The 2651A can source or sink up to ±40 V and ±50 A. Maximum Output Power Voltage Current Quadrant II –10 V @ 13 A –20 V @ 7.7 A –40 V @ 3.3 A

4.3 A @ –20 V

10 A @ –10 V

20 A @ –1.3 V Quadrant IV

10 V @ –13 A

20 V @ –7.7 A 40 V @ –3.3 A –4.3 A @ 20 V –10 A @ 10 V –20 A @ 1.3 V Two Measurement Modes: Digitizing or Integrating Precisely characterize transient and steady-state behavior, including rapidly changing thermal effects, with the two measurement modes in the 2651A. Each mode is defined by its independent analog-to-digital (A/D) converters. The Digitizing Measurement mode enables 1 µs per point measurements. Its 18-bit A/D converters allow you to precisely measure transient characteristics. For more accurate measurements, use its Integrating Measurement mode, which is based on 22-bit A/D converters. Two A/D converters are used with each measurement mode (one for current and the other for voltage), which run simultaneously for accurate source readback that does not sacrifice test throughput. 0 25 50 75 100 125 150 175 200 Voltage (V) Current (A) Time (µs) Volts Current The dual digitizing A/D converters sample at up to 1 μs/point, enabling full simultaneous characterization of both current and voltage waveforms. High Speed Pulsing The 2651A minimizes the unwanted effects of self heating during tests by accurately sourcing and measuring pulses as short as 100 μs. Additional control flexibility enables you to program the pulse width from 100 μs to DC and the duty cycle from 1% to 100%. A single unit can pulse up to 50 A; combine two units to pulse up to 100 A. Typical Applications

  • Power semiconductor, HBLED, and optical device characterization and testing
  • Solar cell characterization and testing
  • Characterization of GaN, SiC, and other compound materials and devices
  • Semiconductor junction temperature characterization
  • High speed, high precision digitization
  • Electromigration studies
  • High current, high power device testing 2 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Through TSP-Link Technology technology, multiple 2651As and selected Series 2600B SMU instruments can be combined to form a larger integrated system with up to 64 channels. Precision timing and tight channel synchronization are guaranteed with built-in 500 ns trigger controllers. True SMU instrument-per-pin testing is assured with the fully isolated, independent channels of the SourceMeter SMU instruments. 26xxB 2651A 2651A Up to 100 A TSP-Link LXI or GPIB to PC Controller Keithley’s TSP and TSP-Link Technologies enable true SMU-per-pin testing without the power and/or channel limitations of a mainframe-based system. Also, when two 2651As are connected in parallel with TSP- Link Technology, the current range is expanded from 50 A to 100 A. When two units are connected in series, the voltage range is expanded from 40 V to 80 V. Built-in intelligence simplifies testing by enabling the units to be addressed as a single instrument, thus creating an industry-best dynamic range (100 A to 1 pA). This capability enables you to test a much wider range of power semiconductors and other devices. Vgs = 2.01 V Vgs = 2.25 V Vgs = 2.50 V Vgs = 2.75 V Vgs = 3.00 V Vgs = 3.25 V Vgs = 3.51 V Vds (V) Id (A) Precision measurements to 50 A (100 A with two units) enable a more complete and accurate characterization. 0.020 0.018 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 0.000 Vgs (V) Rds (ohms) Id = 10 A Id = 20 A Id = 30 A Id = 40 A Id = 50 A 1 μV measurement resolution and current sourcing up to 50 A (100 A with two units) enable low-level Rds measurements to support next- generation devices. The 2651A supports GPIB, LXI, Digital I/O, and Keithley’s TSP-Link Technology for multi-channel synchronization. WWW.TEK.COM | 3 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

KickStart start-up software lets users be ready to make measurements in minutes. Standard Capabilities of Series 2600B SMU Instruments Each 2651A includes all the features and capabilities provided in most Series 2600B SMU instruments, such as:

  • Ability to be used as either a bench-top I-V characterization tool or as a building block component of multiple-channel I-V test systems
  • ACS Basic Edition software for semiconductor component characterization (optional). ACS Basic now features a Trace mode for generating a suite of characteristic curves.
  • Keithley’s Test Script Processor (TSP ®) Technology, which enables creation of custom user test scripts to further automate testing, and also supports the creation of programming sequences that allow the instrument to operate asynchronously without direct PC control.
  • Parallel test execution and precision timing when multiple SMU instruments are connected together in a system
  • LXI compliance
  • 14 digital I/O lines for direct interaction with probe stations, component handlers, or other automation tools
  • USB port for extra data and test program storage via USB memory device Instrument Control Start-up Software KickStart instrument control/start-up software enables users to start making measurements in minutes without programming. In most cases, users merely need to make some quick measurements, graph the data, and store the data to disk for later analysis in software environments such as Excel. KickStart offers:
  • Configure and control up to four SMU instruments for DC or Pulsed I-V test in either the same app, same project, or a combination of the two.
  • Create tests by mixing any of these SMU instruments:

2400 Graphical Series, 2400 Standard Series (DC only),

2600B Series, 2651A, 2657A, and 6430 SourceMeter ® SMU (DC only) instruments.

  • Differentiate SMU instrument channels and their measurement data using labels that are relevant to your device or module.
  • Native X-Y graphing, panning, and zooming; screenshot capturing of graphs.
  • Spreadsheet/tabular viewing of data; export data for further analysis.
  • Annotating of tests; save test setups.
  • GPIB, USB 2.0, Ethernet compliance. 4 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

This document contains specifications and supplemental information for the 2651A High Power System SourceMeter SMU instrument. Specifications are the standards against which the 2651A is tested. Upon leaving the factory, the 2651A meets these specifications. Supplemental and typical values are non-warranted, apply at 23°C, and are provided solely as useful information. Accuracy specifications are applicable for both normal and high-capacitance modes. Source and measurement accuracies are specified at the 2651A terminals under these conditions:

  • 23° ±5°C, <70 percent relative humidity
  • After two-hour warm-up
  • Speed normal (1 NPLC)
  • A/D autozero enabled
  • Remote sense operation or properly zeroed local operation
  • Calibration period: One year WWW.TEK.COM | 5 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Voltage Accuracy Specifications 1, 2 Range SOURCE MEASURE Programming Resolution Accuracy ±(% reading + volts) Noise (Vpp) (typical)

0.1 Hz to 10 Hz

±(% reading + volts) High-Speed ADC Accuracy 4 ±(% reading + volts) 100.000 mV 5 μV 0.02% + 500 μV 100 μV 1 μV 0.02% + 300 μV 0.05% + 600 μV 1.00000 V 50 μV 0.02% + 500 μV 500 μV 10 μV 0.02% + 300 μV 0.05% + 600 μV 10.0000 V 500 μV 0.02% + 5 mV 1 mV 100 μV 0.02% + 3 mV 0.05% + 8 mV 20.0000 V 500 μV 0.02% + 5 mV 1 mV 100 μV 0.02% + 5 mV 0.05% + 8 mV 40.0000 V 500 μV 0.02% + 12 mV 2 mV 100 μV 0.02% + 12 mV 0.05% + 15 mV Current Accuracy Specifications 5 SOURCE MEASURE Range Programming Resolution Accuracy ±(% reading + amps) Noise (Ipp) (typical) 0.1 Hz to 10Hz Default Display Resolution Integrating ADC Accuracy 3 ±(% reading + amps) High-Speed ADC Accuracy 4 ±(% reading + amps) 100.000 nA 2 pA 0.1% + 500 pA 50 pA 1 pA 0.08% + 500 pA 0.08% + 800 pA 1.00000 μA 20 pA 0.1% + 2 nA 250 pA 10 pA 0.08% + 2 nA 0.08% + 4 nA 10.0000 μA 200 pA 0.1% + 10 nA 500 pA 100 pA 0.08% + 8 nA 0.08% + 10 nA 100.000 μA 2 nA 0.03% + 60 nA 5 nA 1 nA 0.02% + 25 nA 0.05% + 60 nA 1.00000 mA 20 nA 0.03% + 300 nA 10 nA 10 nA 0.02% + 200 nA 0.05% + 500 nA 100.000 mA 2 μA 0.03% + 30 μA 1 μA 1 μA 0.02% + 20 µA 0.05% + 50 µA 10.0000 A 500 μA 0.15% + 6 mA 500 μA 100 μA 0.12% + 6 mA 0.12% + 12 mA 20.0000 A 500 μA 0.15% + 8 mA 500 μA 100 μA 0.08% + 8 mA 0.08% + 15 mA 50.0000 A 6 2 mA 0.15% + 80 mA N/A 100 μA 0.05% + 50 mA 7 0.05% + 90 mA 8 NOTES 1. Add 50 µV to source accuracy specifications per volt of HI lead drop. 2. For temperatures 0° to 18°C and 28° to 50°C, accuracy is degraded by ±(0.15 × accuracy specification)/°C. High-capacitance mode accuracy is applicable at 23° ±5°C only. 3. Derate accuracy specification for NPLC setting <1 by increasing error term. Add appropriate typical percent of range term for resistive loads using the table below. NPLC Setting 100 mV Range 1 V to 40 V Ranges 100 nA Range 1 µA to 100 mA Ranges 1 A to 20 A Ranges 4. 18-bit ADC. Average of 1000 samples taken at 1 µs intervals. 5. At temperatures 0° to 18°C and 28° to 50°C; 100 nA to 10 µA accuracy is degraded by ±(0.35 × accuracy specification)/°C. 100 µA to 50 A accuracy is degraded by ±(0.15 × accuracy specification)/°C. High-capacitance mode accuracy is applicable at 23° ±5°C only. 6. 50 A range accessible only in pulse mode. 7. 50 A range accuracy measurements are taken at 0.008 NPLC. 8. Average of 100 samples taken at 1 µs intervals. DC Power Specifications Maximum Output Power 202 W maximum. CAUTION: Carefully consider and configure the appropriate output-off state and source and compliance levels before connecting the 2651A to a device that can deliver energy. Failure to consider the output-off state and source and compliance levels may result in damage to the instrument or to the device under test. 6 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Minimum Programmable Pulse Width 3 100 μs. Note: Minimum pulse width for settled source at a given I/V output and load can be longer than 100 μs. Pulse Width Programming Resolution 1 μs. Pulse Width Programming Accuracy 3 ±5 μs. Pulse Width Jitter 2 μs (typical). Pulse Rise Time (typical) Current Range Rload Rise Time (typical) 50 A 0.05 Ω 26 μs 50 A 0.2 Ω 57 μs 50 A 0.4 Ω 85 μs 20 A 0.5 Ω 95 μs 50 A 0.8 Ω 130 μs

20 A 1 Ω 180 μs

10 A 2 Ω 330 μs

5 A 8.2 Ω 400 μs Pulse DC and pulse DC thermally limited1 +20 A +30 A +50 A –50 A –10 A +10 A +5 A –5 A –20 A –30 A 0 A +10 V–10 V +20 V–20 V 0 V +40 V–40 V Region Region Maximums Maximum Pulse Width 3 Maximum Duty Cycle 4 1 5 A at 40 V DC, no limit 100% 1 10 A at 20 V DC, no limit 100% 1 20 A at 10 V DC, no limit 100% 2 30 A at 10 V 1 ms 50% 3 20 A at 20 V 1.5 ms 40% 4 10 A at 40 V 1.5 ms 40% 5 50 A at 10 V 1 ms 35% 6 50 A at 20 V 330 μs 10% 7 50 A at 40 V 300 μs 1% NOTES 1. Full power source operation regardless of load to 30°C ambient. Above 30°C or power sink operation, refer to “Operating Boundaries” in the 2651A Reference manual for additional power derating information. 2. Quadrants 2 and 4 power envelope is trimmed at 36V and 4.5A. 3. Times measured from the start of pulse to the start off-time; see figure below. Pulse Level Bias Level Start ton Start toff 90% 10% ton toff 10% 4. Thermally limited in sink mode (quadrants 2 and 4) and ambient temperatures above 30°C. See power equations in the 2651A Reference Manual for more information. WWW.TEK.COM | 7 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Additional Source Specifications Noise (10 Hz to 20 MHz) <100 mV peak-peak (typical), <30 mV RMS (typical), 10 V range with a 20 A limit. Overshoot Voltage: <±(0.1% + 10 mV) (typical). Step size = 10% to 90% of range, resistive load, maximum current limit/ compliance. Current: <±(0.1% + 10 mV) (typical). Step Size = 10% to 90% of range, resistive load. See Current Source Output Settling Time specifications for additional test conditions. Range Change Overshoot Voltage: <300 mV + 0.1% of larger range (for <20 V ranges) (typical). <400 mV + 0.1% of larger range (for ≥20 V ranges) (typical). Overshoot into a 100 kΩ load, 20 MHz bandwidth. Current: <5% of larger range + 360 mV/R load (for >10 μA ranges) (typical). I out × Rload = 1 V. Voltage Source Output Time required to reach within 0.1% of final value after source level command is processed on a fixed range. 1 Settling Time Range Settling Time (typical)

1 V <70 μs

10 V <160 μs

20 V <190 μs

40 V <175 μs

Current Source Output Time required to reach within 0.1% of final value after source level command is processed on a fixed range. Settling Time Values below for I out × Rload . Current Range Rload Settling time (typical) 20 A 0.5 Ω <195 μs 10 A 1.5 Ω <540 μs

5 A 5 Ω <560 μs

1 A 1 Ω <80 μs

100 mA 10 Ω <80 μs 10 mA 100 Ω <210 μs 1 mA 1 kΩ <300 μs 100 μA 10 kΩ <500 μs 10 μA 100 kΩ <15 ms 1 μA 1 MΩ <35 ms 100 nA 10 MΩ <110 ms Transient Response Time 10 V and 20 V Ranges: <70 μs for the output to recover to within 0.1% for a 10% to 90% step change in load. 40 V Range: <110 μs for the output to recover to within 0.1% for a 10% to 90% step change in load. Guard Offset Voltage <4 mV, current <10 mA. Remote Sense Operating Range 2 Maximum Voltage between HI and SENSE HI: 3 V. Maximum Voltage between LO and SENSE LO: 3 V. Maximum Impedance Maximum impedance limited by 3 V drop by remote sense operating range. per Source Lead Maximum resistance = 3 V/source current value (amperes) (maximum of 1 Ω per source lead). 3 V = L di/dt. Voltage Output Headroom 5 A Range: Maximum output voltage = 48.5 V – (Total voltage drop across source leads). 10 A Range: Maximum output voltage = 24.5 V – (Total voltage drop across source leads). 20 A Range: Maximum output voltage = 15.9 V – (Total voltage drop across source leads). Overtemperature Protection Internally sensed temperature overload puts unit in standby mode. Limit/Compliance Bipolar limit (compliance) set with single value. Voltage 3: Minimum value is 10mV; accuracy is the same as voltage source. Current 4: Minimum value is 10nA; accuracy is the same as current source. NOTES 1. With measure and compliance set to the maximum current for the specified voltage range. 2. Add 50 µV to source accuracy specifications per volt of HI lead drop. 3. For sink mode operation (quadrants II and IV), add 0.6% of limit range to the corresponding voltage source accuracy specifications. For 100 mV range add an additional 60 mV of uncertainty. Specifications apply with sink mode enabled. 4. For sink mode operation (quadrants II and IV), add 0.6% of limit range to the corresponding current limit accuracy specifications. Specifications apply with sink mode enabled. 8 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Additional Measurement Specifications Contact Check 1 Speed Maximum Measurement Time to Memory for 60Hz (50Hz) Accuracy (1 Year) 23° ±5°C, ±(% reading + ohms) Fast 1.1 ms (1.2 ms) 5% + 15 Ω Medium 4.1 ms (5 ms) 5% + 5 Ω Slow 36 ms (42 ms) 5% + 3 Ω NOTES 1. Includes measurement of SENSE HI to HI and SENSE LO to LO contact resistances. Additional Meter Specifications Maximum Load Impedance Normal Mode: 10 nF (typical), 3 μH (typical). High-Capacitance Mode: 50 μF (typical), 3 μH (typical). Common Mode Voltage 250 V DC. Common Mode Isolation >1 GΩ, <4500 pF. Measure Input Impedance >10 GΩ. Sense High Input Impedance >10 GΩ. Maximum Sense Lead Resistance 1 kΩ for rated accuracy. Overrange 101% of source range, 102% of measure range. High-Capacitance Mode 1,2 Accuracy Specifications 3 Accuracy specifications are applicable in both normal and high-capacitance modes. Voltage Source Output Settling Time Time required to reach within 0.1% of final value after source level command is processed on a fixed range. 4 Voltage Source Range Settling Time with C load = 4.7μF (typical)

1 V 75 μs

10 V 170 μs

20 V 200 μs

40 V 180 μs

Mode Change Delay 100 μA Current Range and Above: Delay into High-Capacitance Mode: 11 ms. Delay out of High-Capacitance Mode: 11 ms. 1 μA and 10 μA Current Ranges: Delay into High-Capacitance Mode: 250 ms. Delay out of High-Capacitance Mode: 11 ms. Measure Input Impedance >10 GΩ in parallel with 25 nF. Voltage Source Range Change Overshoot <400 mV + 0.1% of larger range (typical). Overshoot into a 100 kΩ load, 20 MHz bandwidth. NOTES 1. High-capacitance mode specifications are for DC measurements only and use locked ranges. Autorange is disabled. 2. 100 nA range is not available in high-capacitance mode. 3. Add an additional 2 nA to the source current accuracy and measure current accuracy offset for the 1 µA range. 4. With measure and compliance set to the maximum current for the specified voltage range. WWW.TEK.COM | 9 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Measurement Speed Specifications 1, 2 Maximum Sweep Operation Rates (Operations per Second) for 60 Hz (50 Hz) A/D Converter Speed Trigger Origin Measure To Memory Using User Scripts Measure To GPIB Using User Scripts Source Measure To Memory Using User Scripts Source Measure To GPIB Using User Scripts Source Measure To Memory Using Sweep API Source Measure To GPIB Using Sweep API

0.001 NPLC Internal 20000 (20000) 9800 (9800) 7000 (7000) 6200 (6200) 12000 (12000) 5900 (5900)

0.001 NPLC Digital I/O 8100 (8100) 7100 (7100) 5500 (5500) 5100 (5100) 11200 (11200) 5700 (5700)

0.01 NPLC Internal 4900 (4000) 3900 (3400) 3400 (3000) 3200 (2900) 4200 (3700) 4000 (3500)

0.01 NPLC Digital I/O 3500 (3100) 3400 (3000) 3000 (2700) 2900 (2600) 4150 (3650) 3800 (3400)

0.1 NPLC Internal 580 (480) 560 (470) 550 (465) 550 (460) 560 (470) 545 (460)

0.1 NPLC Digital I/O 550 (460) 550 (460) 540 (450) 540 (450) 560 (470) 545 (460)

1.0 NPLC Internal 59 (49) 59 (49) 59 (49) 59 (49) 59 (49) 59 (49)

1.0 NPLC Digital I/O 58 (48) 58 (49) 59 (49) 59 (49) 59 (49) 59 (49)

HS ADC Internal 38500 (38500) 18000 (18000) 10000 (10000) 9500 (9500) 14300 (14300) 6300 (6300) HS ADC Digital I/O 12500 (12500) 11500 (11500) 7500 (7500) 7000 (7000) 13200 (13200) 6000 (6000) High Speed ADC Burst Measurement Rates 3 Burst Length (readings) Readings per Second Bursts per Second 100 1,000,000 400 500 1,000,000 80 1000 1,000,000 40 2500 1,000,000 16 5000 1,000,000 8 Maximum Single Measurement Rates (operations per second) for 60 Hz (50 Hz) A/D Converter Speed Trigger Origin Measure To GPIB Source Measure To GPIB Source Measure Pass/Fail To GPIB

0.001 NPLC Internal 1900 (1800) 1400 (1400) 1400 (1400)

0.01 NPLC Internal 1450 (1400) 1200 (1100) 1100 (1100)

0.1 NPLC Internal 450 (390) 425 (370) 425 (375)

1.0 NPLC Internal 58 (48) 57 (48) 57 (48)

Maximum Measurement Range Change Rate >4000 per second for >10 µA (typical). Maximum Source Range Change Rate >325 per second for >10 µA, typical. When changing to or from a range ≥1 A, maximum rate is >250 per second, typical. Command Processing Time Maximum time required for the output to begin to change following the receipt of the smua.source.levelv or smua.source.leveli command. <1 ms typical. NOTES 1. Tests performed with a 2651A on channel A using the following equipment: Computer hardware (Intel ® Pentium ® 4 2.4 GHz, 2 GB RAM, National Instruments™ PCI-GPIB). Driver (NI-488.2 Version 2.2 PCI-GPIB). Software (Microsoft ® Windows ® XP, Microsoft Visual Studio ® 2010, VISA™ version 4.1). 2. Exclude current measurement ranges less than 1 mA. 10 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Triggering and Synchronization Specifications Triggering Trigger In to Trigger Out: 0.5 μs (typical). Trigger In to Source Change 1: 10 μs (typical). Trigger Timer Accuracy: ±2 μs (typical). Source Change 1 After LXI Trigger: 280 μs (typical). Synchronization Single-Node Synchronized Source Change 1: <0.5 μs (typical). Multi-Node Synchronized Source Change 1: <0.5 μs (typical). NOTES 1. Fixed source range with no polarity change. Supplemental Information Front Panel Interface Two-line vacuum fluorescent display (VFD) with keypad and navigation wheel. Display Show error messages and user defined messages. Display source and limit settings. Show current and voltage measurements (6½-digit to 4½-digit). View measurements stored in dedicated reading buffers. Keypad Operations Change host interface settings. Save and restore instrument setups. Load and run factory and user defined test scripts that prompt for input and send results to the display. Store measurements into dedicated reading buffers. Programming Embedded Test Script Processor (TSP ®) scripting engine is accessible from any host interface. Responds to individual instrument control commands. Responds to high speed test scripts comprised of instrument control commands and Test Script Language (TSL) statements (for example, branching, looping, and math). Able to execute high speed test scripts stored in memory without host intervention. Minimum User Memory Available 16 MB (approximately 250,000 lines of TSP code). TSP Toolkit Software Visual Studio code extension for building and running TSP scripts. Includes an instrument console for communicating with any TSP enabled instrument in an interactive manner. Reading Buffers Nonvolatile memory uses dedicated storage areas reserved for measurement data. Reading buffers are arrays of measurement elements. Each element can hold the following items: Measurement Source setting (at the time the measurement was taken) Measurement status Timestamp Range information Two reading buffers are reserved for each 2651A channel. Reading buffers can be filled using the front panel STORE key and retrieved using the RECALL key or host interface. Buffer Size, with timestamp and source setting >60,000 samples. Buffer Size, without timestamp and source setting >140,000 samples. WWW.TEK.COM | 11 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

System Expansion The TSP-Link ® expansion interface allows TSP-enabled instruments to trigger and communicate with each other. Cable type: Category 5e or higher LAN crossover cable. Three meter (9.84 ft) maximum between each TSP-enabled instrument. A maximum of 32 TSP-Link nodes can be interconnected. Each source-measure instrument uses one TSP-Link node. Timer Free-running 47-bit counter with 1 MHz clock input. Resets each time instrument power is turned on. If the instrument is not turned off, the timer is reset to zero every 4 years. Timestamp TIMER value is automatically saved when each measurement is triggered. Resolution 1 µs. Timestamp Accuracy ±100 ppm. General Digital I/O Interface +5VDC 5.1 kΩ 100 Ω +5V Pin (on DIGITAL I/O connector) Digital I/O Pin (on DIGITAL I/O connector) GND Pin (on DIGITAL I/O connector) Rear Panel 600 mA Solid State Fuse Read by firmware Written by firmware Connector 25-pin female D. Input/Output Pins 14 open drain I/O bits. Absolute Maximum Input Voltage 5.25 V. Absolute Minimum Input Voltage –0.25 V. Maximum Logic Low Input Voltage 0.7 V, +850 μA max. Minimum Logic High Input Voltage 2.1 V, +570 μA. Maximum Source Current (flowing out of digital I/O bit) +960 μA. Maximum Sink Current At Maximum Logic Low Voltage (0.7) –5.0 mA. Absolute Maximum Sink Current (flowing into digital I/O pin) –11 mA. 5 V Power Supply Pin Limited to 250 mA, solid-state fuse protected. Output Enable Pin Active high input pulled down internally to ground with a 10 kΩ resistor; when the output enable input function has been activated, the 2651A channel will not turn on unless the output enable pin is driven to >2.1 V (nominal current = 2.1 V/10 kW = 210 μA). 12 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

IEEE-488 IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status topology. RS-232 Baud rates from 300 bps to 115200 bps. Programmable number of data bits, parity type, and flow control (RTS/ CTS hardware or none). When not programmed as the active host interface, the 2651A can use the RS-232 interface to control other instrumentation. Ethernet RJ-45 connector, LXI, 10/100BT, Auto MDIX. LXI Compliance LXI Class C 1.2. Total Output Trigger Response Time 245 μs minimum, 280 μs (typical), (not specified) maximum. Receive Lan[0-7] Event Delay Unknown. Generate Lan[0-7] Event Delay Unknown. Expansion Interface The TSP-Link Technology expansion interface allows TSP-enabled instruments to trigger and communicate with each other. Cable Type Category 5e or higher LAN crossover cable. 3 meters maximum between each TSP-enabled instrument. USB USB 2.0 host controller. Power Supply 100 V to 250 V AC, 50 Hz to 60 Hz (autosensing), 550 VA maximum. Cooling Forced air; side and top intake and rear exhaust. Warranty 1 year. EMC Conforms to European Union EMC Directive. Safety UL listed to UL61010-1:2004. Conforms to European Union Low Voltage Directive. Bench Configuration (with handle and feet) Weight 9.98 kg (22 lbs). Environment For indoor use only. Altitude Maximum 2000 meters above sea level. Operating 0° to 50°C, 70% relative humidity up to 35°C. Derate 3% relative humidity/°C, 35° to 50°C. Storage –25° to 65°C.

Ordering Information

2651A High Power System SourceMeter ® SMU Instrument Supplied Accessories 2651A-KIT-1A Low Impedance Cable Assembly (1 m) CS-1592-2 High Current Phoenix Connector (male) CS-1626-2 High Current Phoenix Connector (female) CA-557-1 Sense Line Cable Assembly (1 m) 7709-308A Digital I/O Connector 1746946XX TSP-Link/Ethernet Cable Rack Mount Kit Documentation Available at www.tek tronix.com WWW.TEK.COM | 13 DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

2600-KIT Screw Terminal Connector Kit ACS-BASICFL Component Charaterization Software KickStart Instrument Control Software Warranty Information Warranty Summary This section summarizes the warranties of the 2651A. For complete warranty information, refer to the Tektronix warranty page at www.tek.com/service/warranties/warranty-2. Any portion of the product that is not manufactured by Keithley is not covered by this warranty and Keithley will have no duty to enforce any other manufacturer’s warranties. Hardware Warranty Keithley Instruments, Inc. warrants the Keithley manufactured portion of the hardware for a period of one year from defects in materials or workmanship; provided that such defect has not been caused by use of the Keithley hardware which is not in accordance with the hardware instructions. The warranty does not apply upon any modification of Keithley hardware made by the customer or operation of the hardware outside the environmental specifications. Software Warranty Keithley warrants for the Keithley produced portion of the software or firmware will conform in all material respects with the published specifications for a period of ninety (90) days; provided the software is used on the product for which it is intended in accordance with the software instructions. Keithley does not warrant that operation of the software will be uninterrupted or error-free, or that the software will be adequate for the customer’s intended application. The warranty does not apply upon any modification of the software made by the customer. 14 | WWW.TEK.COM DATASHEET2651A 50 A, High Power System SourceMeter® SMU Instrument

Find more valuable resources at TEK.COM in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.

011525 SBG 1KW-73819-0

Contact Information: Australia 1 800 709 465 Austria* 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3530-8901 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3086 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 88 69 35 25 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People’s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 565 1455 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Rev. 02.2022