- Precision multimeter with 3½- to 7½-digit resolution
- Capture and display waveforms or transients with
1 MS/sec digitizer
- Large internal memory buffer; store over 11 million readings in standard mode or 27.5 million in compact mode
- 14 PPM basic one-year DCV accuracy
- 100 mV, 1 Ω, and 10 µA ranges offer the sensitivity needed for measuring low level signals such as portable device sleep mode currents
- Make accurate low resistance measurements with offset compensated ohms, four-wire, and dry circuit functions
- Auto-calibration feature improves accuracy and stability by minimizing temperature and time drift
- Display more with five-inch, high resolution touchscreen interface
- Readings and screen images can be saved quickly via the front panel USB memory port
- Multiple connectivity options: GPIB, USB, and LXI- compliant LAN interfaces
- Two-year specifications enable longer calibration cycles The DMM7510 combines all the advantages of a precision digital multimeter, a graphical touchscreen display, and a high speed, high resolution digitizer to create an industry first: a graphical sampling multimeter. The digitizer gives the DMM7510 unprecedented signal analysis flexibility; the five-inch capacitive touchscreen display makes it easy to observe, interact with, and explore measurements with “pinch and zoom” simplicity. This combination of high performance and high ease of use offers unparalleled insight into your test results. Capture Waveforms with the Built-in 1 MS/sec Digitizer Capturing and displaying waveforms and transient events just got easier with the DMM7510’s voltage or current digitizing function. The built-in 1 MS/sec, 18-bit digitizer makes it possible to acquire waveforms without the need to use a separate instrument. The digitizing functions employ the same ranges that the DC voltage and current functions use to deliver exceptional dynamic measurement range. In addition, the voltage digitizing function uses the same DC voltage input impedance (10 GΩ or 10 MΩ) levels to reduce loading significantly on the DUT. The built-in graphing utility supports displaying and comparing measurements or waveforms from up to four reading buffers at once. DMM7510 7½-Digit Graphical Sampling Multimeter DATASHEET
Advanced triggering options make it possible to capture a signal at precisely the right point. Capture the current drain from all the operating states – sleep mode to active transmit mode – of a component or a product with the DMM7510’s digitizing function. Focus in on characteristics of the wave shapes with the touchscreen pinch and zoom features. Accurately Measure and Visualize Ultra-Low Current Drain Levels Determine the current drain of the components such as the microcontroller (MCU) in your low-power, battery-operated product as well as the product’s total current draw. In addition, profile the current drain in all of the product’s operating states from its sleep mode to its transmit mode. Using the enhanced accuracy DC current function, the DMM7510 can measure a 1 µA sleep mode current with 1 pA resolution and with 0.375 nA tolerance. Furthermore, using the digitizing current function, the DMM7510 can capture the current wave shapes as the product transitions from sleep mode to transmit mode. Make Demanding Measurements with Confidence The DMM7510’s design makes the most of Keithley’s low level measurement expertise. Features like the low noise input stage and the 32-bit A-to-D converter allow this instrument to deliver DC accuracies typically only found in metrology-grade instrumentation—but at about half the price of those solutions. The DMM7510’s 100 mV, 10 Ω, and 10 µA ranges deliver the sensitivity needed to measure low signals with confidence when characterizing today’s demanding electronic designs. In addition to one- and two- year accuracy specifications, an auto-calibration function ensures greater accuracy between calibration cycles. 2µV 1µV 0µV –1µV –2µV Volts 6½ Digit 8½ Digit DMM7510 One Power Line Cycle Noise Performance The DMM7510 provides noise performance equivalent to or better than many 8½-digit DMMs. Comparison of the DMM7510’s 1 VDC noise performance with t˚hat of typical 6½- and 8½-digit multimeters. All data was taken at 1 NPLC with a low thermal short applied to the input.
15 Measurement Functions
The DMM7510 provides 15 basic measurement functions. In addition to the digitizing voltage and current functions, it includes capacitance, ACV and ACI, temperature (RTD, thermistor, and thermocouple), 2- and 4-wire resistance, dry circuit ohms, period, frequency, diode test, and DC voltage ratio. The instrument’s flat menu structure allows for fast configuration and improves usability. Its intuitive design lets you to learn how to operate the instrument and begin making device measurements faster and with greater confidence. RTD, Thermistor, Thermocouple Easily accessible current fuses Measure Complete and External Trigger (8503 BNC Accessory Available) GPIB interfaceSix user-defined digital I/Os USB 2.0 interface LAN/LXI interface Online HELP is just a button press away Store test results and screen images quickly via the USB 2.0 memory port Lower swipe screen speeds access to often-used features Five-inch touchscreen displays more information simultaneously Rotary control knob offers an alternative to touchscreen navigation Front/rear input selector Designed for Higher T esting Productivity In addition to its advanced touchscreen, the DMM7510’s front panel offers a variety of features that enhance its speed, user- friendliness, and learnability, including a USB 2.0 memory I/O port, a HELP key, a rotary navigation/control knob, and front/ rear input selector button. All front-panel buttons are backlit to enhance visibility. The rear panel of the DMM7510 provides connections and controls that simplify configuring multi-instrument test solutions, including input connectors, remote control interfaces (GPIB, USB 2.0 and LXI/Ethernet), a D-sub 9-pin digital I/O port (for internal/ external trigger signals and handler control), and TSP-Link ® jacks for connecting to other TSP- enabled instruments. WWW.TEK.COM | 3 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
DMM7510 Measurement Capabilities DC Voltage AC Voltage DC Current AC Current Resistance (2-wire) Resistance (4-wire) Dry Circuit Resistance Capacitance Period Frequency Digitize Voltage Digitize Current 10nV 100nV Logarithmic Scale Linear Scale 1pA 1nA 100nΩ 1µΩ 0.1pF –200°C –80°C –200°C –200°C 1820°C 150°C 850°C 850°C 2µs 3Hz 1µV 0.1nA 1010V 707VRMS 10.1A 10.1A 1.2GΩ 2.4kΩ 1µΩ 1.2GΩ 1.2mF 330ms 500kHz 1010V 10.1A 1f 1p 1n 1µ 1m 1 1k 1M 1G Thermocouple Thermistor 3-Wire RTD 4-Wire RTD –500° 0° 500° 1000° 1500° 2000° Flexible System Integration and Programming To offer users maximum programming flexibility and simplify configuring multi-instrument test systems, the DMM7510 includes Keithley’s powerful Test Script Processor (TSP ®) system and SCPI programming mode. The embedded scripting capability allows running powerful test scripts directly on the instrument, without the need for an external PC controller. These test scripts are complete test programs based on an easy-to-use yet highly efficient and compact scripting language, Lua (www.lua.org). Scripts are a collection of instrument control commands and/or program statements. Program statements control script execution and provide facilities such as variables, functions, branching, and loop control. This allows you to create powerful measurement applications with significantly reduced development times. Test scripts can contain any sequence of routines that are executable by conventional programming languages (including decision-making algorithms), so the instrument can manage every facet of the test without the need to communicate with a PC for decision-making. This eliminates delays due to GPIB, Ethernet or USB traffic congestion and greatly improves overall test times. TSP technology also offers “mainframe-less channel expansion.” The TSP-Link ® channel expansion bus and a 100 Base T Ethernet cable allow connecting multiple DMM7510s with other TSP-enabled instruments in a master-slave configuration so they operate as a single integrated system. These instruments include the 2450 and 2460 Graphical SourceMeter ® SMU instruments, Series 2600B SourceMeter SMU instruments, and the Series 3700A Switch/Multimeter systems. TSP-Link supports up to 32 units per GPIB or IP address, so it’s easy to scale a system to fit the requirements of an application. A standard SCPI programming mode supports taking advantage of all of the DMM7510’s new features when programming remotely. In addition, the instrument is code- compatible with the SCPI language, which many other DMMs use. This code compatibility avoids the need to rewrite code that is normally associated with upgrading to a new instrument with new capabilities. Ready-to-use Instrument Drivers Simplify Programming Need to create your own customized application software? Native National Instruments LabVIEW ®, IVI-C, and IVI-COM drivers are available for downloading at www.tek.com to simplify the programming process. 4 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Instrument Control Software Keithley’s KickStart instrument control software lets you begin taking measurements in minutes. KickStart combines a wide range of functions to enhance testing productivity:
- Instrument-specific UI panel
- Manual instrument configuration
- Basic reading display and tabular viewing of data
- Datalogging
- Native X-Y data graphing
- Panning and zooming
- Basic statistics (native to instrument, mX+b)
- Saving/exporting data
- Connect using any remote interface (GPIB, USB, LAN)
- Saving instrument setups
- Screenshot capture
- Command line dialog box WWW.TEK.COM | 5 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
This document contains specifications and supplemental information for the DMM7510 7½-Digit Graphical Sampling Multimeter instrument. Specifications are the standards against which the DMM7510 is tested. Upon leaving the factory, the Model DMM7510 meets these specifications. Supplemental and typical values are nonwarranted, apply at 23°C (73°F), and are provided solely as useful information. Measurement accuracies are specified at the DMM7510 terminals under these conditions:
- Temperature 23° ±5°C, 5% to 80% relative humidity, noncondensing.
- After a 90-minute warmup period.
- 1 PLC or 5 PLC; for NPLC settings less than 1 PLC, add appropriate ppm of range for peak noise uncertainty from the RMS noise table.
- Autozero enabled unless otherwise noted.
- Remote sense operation or properly zeroed local operation.
- Calibration period: One year or two years (calibration period may vary depending on customer requirements).
- TACAL = Ambient temperature of last automatic calibration.
- TCAL = Ambient temperature of last external calibration; factory calibration performed at 23° ±1°C. DC Voltage Accuracy (Input impedance AUTO) Range 1 Resolution Input Impedance 2 Accuracy ±(ppm of reading + ppm of range)
24 Hour
TCAL ±1°C 2
90 Day
TCAL ±5°C
1 Year
TCAL ±5°C
2 Year
TCAL ±5°C Temperature Coefficient 3 100.00000 mV 4 10 nV >10 GΩ or 10 MΩ ±1 % 6 + 9 12 + 9 18 + 9 29 + 9 0.1 + 2.5
1.0000000 V 4 100 nV >10 GΩ or
10 MΩ ±1 % 4 + 1 9 + 2 15+ 2 26 + 2 0.1 + 0.5
10.000000 V 4 1 µV >10 GΩ or
100.00000 V 4 10 µV 10 MΩ ±1 % 8 + 3 (18 + 5) 5 (22 + 5) 5 (30 + 5) 5 (0.15 + 0.05) 5 35 + 5 40 + 5 45 + 5 2.0 + 0.5 1000.0000 V 4, 6 100 µV 10 MΩ ±1 % 8 + 3 (19 + 5) 5 (23 + 5) 5 (31 + 5) 5 (0.15 + 0.05) 5 35 + 5 40 + 5 45 + 4 2.0 + 0.5 RMS Noise (additional peak noise uncertainty) 7 Applies to ±ppm of range. Peak noise uncertainty is included in DC specifications for ≥1 PLC. Add peak noise uncertainty to measurements for <1 PLC. Input impedance set to Auto. NOTES 1. 20% overrange on all ranges except 1% for 1000 V range. 2. Relative to calibration accuracy. 3. Add per degree from T CAL ±5°C. 4. When properly zeroed using the Rel function with external cables. 5. Specified within 30 days of autocalibration, T OPER ±5°C from T ACAL . 6. For signal levels greater than 500 V, add 0.02 ppm/V to the ppm of the readings specification for measurements exceeding 500 V. 7. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. V RMS noise is typical. Additional peak noise is guaranteed. 6 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Examples: 10 V at 0.006 PLC: 1.2 (from Accuracy table) + 11 (additional peak noise uncertainty) = 12.2 ppm of range. 10 V at 1 PLC: 1.2 + 0 = 1.2 ppm of range. NPLC Digits 100 mV 1 V 10 V 100 V 1000 V 0.006 4½ 6 (42) 3 (18) 1 (11) 20 (100) 3 (18) 0.0005 3½ 30 (220) 20 (150) 20 (130) 120 (690) 20 (150) DC Voltage Sense Accuracy Accuracy ±(ppm of reading + ppm of range) Range 24 Hour TCAL ±1°C TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 9 100.00000 mV 6 + 14 12 + 14 18 + 14 29 + 14 0.1 + 2.5 1.0000000 V 4 + 1.5 9 + 3 15 + 3 26 + 3 0.1 + 0.5 DC Voltage Ratio For input signals ≥1% of the range, ratio accuracy = ±[[V INPUT ppm of reading + V INPUT ppm of range * (V INPUT range/V INPUT input)] + [VSENSE ppm of reading + VSENSE ppm of range * (V SENSE range/V SENSE input)]]. DC Voltage Characteristics ADC Linearity 1.0 ppm of reading + 1.0 ppm of range. Input Impedance 100 mV to 10 V Ranges: Selectable >10 GΩ || <400 pF (auto) or 10 MΩ ±1% (10 MΩ). 100 V to 1000 V Ranges: 10 MΩ ±1%. Input Bias Current <50 pA at 23°C under the following conditions: Autozero off or input impedance 10 MΩ. Common Mode Current <2.1 µA peak-peak in 1 MHz bandwidth. <100 nA peak-peak in 1 kHz bandwidth. Common Mode Voltage 500 Vpeak LO terminal to chassis maximum. DC Voltage Autozero Off Error For ±1°C and ≤10 minutes, add ±(8 ppm of reading + 15 µV). Normal Mode Rejection For DC voltage, line frequency ±0.1%. 5 PLC 1 PLC ≤0.2 PLC ≤0.01 PLC Line Sync On 110 dB 90 dB 45 dB — Line Sync Off 60 dB 60 dB — — Common Mode Rejection For DC voltage and 1kΩ unbalanced in LO terminal; AC CMRR is 70 dB. NPLC 5 1 0.2 ≤ 0.2 Line Sync On On On Off CMRR 140 dB 140 dB 120 dB 80 dB NOTES 8. With line sync on. 9. Add per degree from T CAL ±5°C. WWW.TEK.COM | 7 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Enhanced Accuracy (within 30 days of autocalibration, T OPER ±5°C from TACAL) 10 Range 11 Resolution Test Current 12 (±5%) Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 13 TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 14 1.0000000 Ω 0.1 µΩ 10 mA 15 + 50 30 + 50 30 + 50 30 + 50 0.15 + 0.1 10.000000 Ω 1 µΩ 10 mA 15 + 5 30 + 5 30 + 5 30 + 5 0.15 + 0.1 100.00000 Ω 10 µΩ 1 mA 12 + 4 27 + 4 27 + 4 27 + 4 0.15 + 0.1 1.0000000 kΩ 100 µΩ 1 mA 12 + 3 24 + 3 24 + 3 24 + 3 0.15 + 0.1 10.000000 kΩ 15 1 mΩ 100 µA 13 + 3 30 + 3 30 + 3 30 + 3 0.15 + 0.1 100.00000 kΩ 15, 16 10 mΩ 10 µA 13 + 3 30 + 3 30 + 3 30 + 3 0.15 + 0.1 1.0000000 MΩ 15, 17 100 mΩ 10 µA 14 + 3 30 + 4 30 + 4 30 + 4 0.15 + 0.1 10.000000 MΩ 18 1 Ω 0.69 µA || 10 MΩ 150 + 6 200 + 10 200 + 10 200 + 10 70 + 1 100.00000 MΩ 18 10 Ω 0.69 µA || 10 MΩ 800 + 30 2000 + 30 2000 + 30 2000 + 30 385 + 1 1.0000000 GΩ 18 100 Ω 0.69 µA || 10 MΩ 9000 + 100 9000 + 100 9000 + 100 9000 + 100 3000 + 1 Accuracy 19 Range 20 Resolution Test Current 21 (±5%) Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 22 TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 23 1 Ω 0.1 µΩ 10 mA 15 + 50 40 + 50 50 + 50 70 + 50 2.5 + 5 10 Ω 1 µΩ 10 mA 15 + 5 40 + 5 50 + 5 70 + 5 2.5 + 0.5 100 Ω 10 µΩ 1 mA 12 + 4 35 + 4 47 + 4 65 + 4 5 + 0.25 1 kΩ 100 µΩ 1 mA 12 + 3 30 + 3 41 + 3 65 + 3 5 + 0.25 10 kΩ 24 1 mΩ 100 µA 10 + 3 30 + 3 42 + 3 65 + 3 2.5 + 0.25 100 kΩ 24, 25 10 mΩ 10 µA 13 + 3 38 + 3 50 + 3 65 + 3 5 + 1
1 MΩ 24, 26 100 mΩ 10 µA 14 + 3 38 + 5 50 + 5 65 + 5 5 + 1
10 MΩ 27 1 Ω 0.69 µA || 10 MΩ 150 + 6 200 + 10 400 + 10 600 + 12 70 + 1 100 MΩ 27 10 Ω 0.69 µA || 10 MΩ 800 + 30 2000 + 30 2000 + 30 2600 + 30 385 + 1 1 GΩ 27 100 Ω 0.69 µA || 10 MΩ 9000 + 200 9000 + 200 13000 + 200 14000 + 200 3000 + 1 NOTES 10. Specifications are for 4-wire resistance, offset compensation on for ≤10 kΩ measurements, and offset compensation off for ≥10 kΩ measurements. 1 Ω range is 4-wire only. For 2-wire, with Rel, add 50 mΩ to ppm of range uncertainty. Without Rel and with 1756 test leads, add 100 mΩ to ppm of range uncertainty. 11. 20% overrange on all ranges. 12. Test current with offset compensation off, ±5%. 13. Relative to calibration accuracy. 14. Add per degree from T CAL ±5°C. 15. Specifications are for external cable and load capacitance <1nF. 16. For offset compensation on, add 10ppm uncertainty to ppm of reading. 17. For 4-wire 1 MΩ, open lead detector on, add 10 ppm uncertainty to ppm of reading. 18. Specified for <10% lead resistance mismatch in HI and LO. 19. Specifications are for 4-wire resistance, offset compensation on for ≤10 kΩ measurements, and offset compensation off for ≥10 kΩ measurements. 1Ω range is 4-wire only. For 2-wire, with Rel, add 50 mΩ to ppm of range uncertainty. Without Rel and with 1756 test leads, add 100 mΩ to ppm of range uncertainty. 20. 20% overrange on all ranges. 21. Test current with offset compensation off. 22. Relative to calibration accuracy. 23. Add per degree from T CAL ±5°C. 24. Specifications are for external cable and load capacitance <1 nF. 25. For offset compensation on, add 10ppm of uncertainty to ppm of reading. 26. For 4-wire, 1 MΩ, open lead detection on, add 10ppm uncertainty to ppm of reading. 27. Specified for <10% lead resistance mismatch in HI and LO. 8 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Resistance Open Circuit DC Voltage 28 Range 20 2-wire Offset Compensation Off Offset Compensation On 4-wire 4-wire 1 Ω – 9.2 V 9.5 V 10 Ω 9.2 V 9.2 V 9.5 V 100 Ω, 1 kΩ 14.0 V 14.2 V 14.3 V 10 kΩ 9.5 V 9.5 V 0.0 V 100 kΩ, 1 MΩ 12.7 V 14.3 V 0.0 V (100 kΩ range only) 10 MΩ to 1 GΩ 6.9 V 6.9 V – 4-Wire Ohms (≤10kΩ) Offset Compensation On RMS Noise (additional peak noise uncertainty) 29 Applies to ± ppm of range. Peak noise uncertainty is included in DC specifications for ≥1 PLC. Add peak noise uncertainty to measurements for <1 PLC. Examples 1 kΩ at 0.006 PLC: 3 (from Accuracy table) + 26 (additional peak noise uncertainty) = 29 ppm of range. 1 kΩ at 1 PLC: 3 + 0 = 3 ppm of range. NPLC Digits 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 0.006 4½ 110 (710) 10 (70) 10 (70) 4 (26) 10 (60) 0.0005 3½ 520 (3420) 50 (340) 50 (340) 40 (220) 50 (300) 2-Wire Ohms RMS Noise (additional peak noise uncertainty) 29 Applies to ± ppm of range. Peak noise uncertainty is included in DC specifications for ≥1 PLC. Add peak noise uncertainty to measurements for <1 PLC. Examples 10 kΩ at 0.006 PLC: 3 (from Accuracy table) + 5 (50 mΩ with Rel ) + 43 (additional peak noise uncertainty) = 51 ppm of range. 10 kΩ at 1 PLC: 3 + 5 + 0 = 8 ppm of range. NPLC Digits 10 Ω 100 Ω 1 kΩ 10 kΩ 5 7½ 1.1 0.8 0.1 0.2 1 7½ 0.6 0.6 0.09 0.4 0.006 4½ 6 (50) 6 (50) 3 (21) 6 (43) 0.0005 3½ 30 (300) 30 (230) 20 (150) 30 (210) NOTES 28. Open circuit voltage is typical, measured from input HI to LO, SHI and SLO open. For 1 Ω to 1 MΩ ranges using an external digital multimeter (DMM) set to 10 MΩ input impedance; for 10 MΩ to 1 GΩ ranges, set external DMM to >10 GΩ input impedance. 29. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. RMS noise is typical. Additional peak noise is guaranteed. 30. With line sync on. WWW.TEK.COM | 9 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Resistance Characteristics Maximum 4-Wire Ohms Lead Resistance 5 Ω per lead for 1Ω range, 10% of range per lead for 10 Ω to 1 kΩ ranges; 1 kΩ per lead for all other ranges. Offset Compensation Selectable on 4-wire, 1 Ω to 100 kΩ ranges. Open Lead Detector Default is off. Autozero Off Error For 2-wire ohms, ±1°C and ≤10 minutes, add ±(8ppm of reading) + 1.5 mΩ for 10 Ω, 15 mΩ for 100 Ω and 1 kΩ ranges, 150 mΩ for 10 kΩ range, 1.5 Ω for 100 kΩ range, and 15 Ω for all other ranges. For 4-wire ohms, ±1°C and ≤10 minutes, add ±(8 ppm of reading). Input Current Limit For signals with a magnitude of +12 V to +40 V or –12 V to –40 V: ±13 mA source or sink, typical. For signals with a magnitude of greater than +40 V or –40 V: ±130 µA source or sink, typical. Dry Circuit Resistance Enhanced Accuracy (within 30 days of autocalibration, T OPER ±5ºC from TACAL) Range 31 Resolution Test Current 35 (±5%) Open Circuit DUT Voltage 32 Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 33 TCAL ±5°C TCAL ±5°C 2 years TCAL ±5°C Temperature Coefficient 34 1.000000 Ω 1 µΩ 10 mA 25 mV 25 + 80 50 + 80 50 + 80 50 + 80 1.5 + 0.1 10.00000 Ω 10 µΩ 1 mA 25 mV 25 + 80 50 + 80 50 + 80 50 + 80 1.5 + 0.1 100.0000 Ω 100 µΩ 100 µA 25 mV 25 + 80 90 + 80 90 + 80 90 + 80 1.5 + 0.1 1.000000 kΩ 1 mΩ 10 µA 25 mV 25 + 80 180 + 80 180 + 80 180 + 80 1.5 + 0.1 10.00000 kΩ 10 mΩ 5 µA 25 mV 25 + 80 320 + 80 320 + 80 320 + 80 1.5 + 0.1 Accuracy Range 31 Resolution Test Current 35 (±5%) Open Circuit DUT Voltage 32 Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 33 TCAL ±°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 34 1.000000 Ω 1 µΩ 10 mA 25 mV 25 + 80 50 + 80 70 + 80 90 + 80 2.5 + 1 10.00000 Ω 10 µΩ 1 mA 25 mV 25 + 80 50 + 80 70 + 80 90 + 80 5 + 1 100.0000 Ω 100 µΩ 100 µA 25 mV 25 + 80 90 + 80 140 + 80 200 + 80 2.5 + 1 1.000000 kΩ 1 mΩ 10 µA 25 mV 25 + 80 180 + 80 400 + 80 600 + 80 5 + 1 10.00000 kΩ 10 mΩ 5 µA 25 mV 25 + 80 320 + 80 800 + 80 1300 + 80 8 + 1 RMS Noise (additional peak noise uncertainty ) 36 Applies to ± ppm of range. Peak noise uncertainty is included in DC specifications for ≥1 PLC. Add peak noise uncertainty to measurements when < 1 PLC. NOTES 31. 20% overrange on all ranges, except 2.4 kΩ for the 10 kΩ range. 32. Maximum clamp voltages are DC, typical accuracy is ±20%. Add 20% for offset compensation on. 33. Relative to calibration accuracy. 34. Add per degree from T CAL ±5°C. 35. Test current with offset compensation off. 36. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. RMS noise is typical. Additional peak noise is guaranteed. 10 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Examples: 10 Ω at 0.2 PLC: 80 (from Accuracy table) + 230 (additional peak noise uncertainty) = 310 ppm of range. 10 Ω at 1 PLC: 80 + 0 = 80 ppm of range. NPLC Digits 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 5 7½ 10 11 6 5 0.9 1 7½ 9 9 7 7 0.8 0.2 37 6½ 30 (130) 30 (120) 30 (120) 30 (120) 3 (16) 0.2 6½ 60 (220) 60 (230) 50 (190) 50 (190) 9 (35) 0.06 5½ 70 (350) 70 (350) 50 (290) 50 (280) 20 (90) 0.006 4½ 130 (750) 120 (830) 110 (700) 100 (690) 20 (110) 0.0005 3½ 520 (3550) 530 (3520) 530 (3380) 500 (3370) 100 (670) Dry Circuit Resistance Characteristics Maximum 4-Wire Ohms Lead Resistance 0.5 Ω per lead for 1 Ω range. 10% of range per lead for 10 Ω to 100 Ω ranges. 50 Ω per lead for 1 kΩ to 10 kΩ ranges. Input Current Limit For signals greater than ±20 mV, current limited, ±13 mA typical. Offset Compensation Selectable on 1 Ω to 10 kΩ ranges. Autozero Off Error For ±1°C and ≤10 minutes, add ±8 ppm of reading. DC Current Enhanced Accuracy (within 30 days of autocalibration, T OPER ±5°C from TACAL) Range 38 Resolution Maximum Burden Voltage Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 39 TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 40 10.000000 µA 1 pA 15 mV 30 + 30 75 + 30 75 + 30 75 + 30 0.15 + 0.1 100.00000 µA 10 pA 15 mV 20 + 5 60 + 9 60 + 9 60 + 9 0.15 + 0.1 1.0000000 mA 100 pA 15 mV 30 + 5 60 + 9 60 + 9 60 + 9 0.15 + 0.1 10.000000 mA 1 nA 20 mV 40 + 5 60 + 9 60 + 9 60 + 9 0.15 + 0.1 100.00000 mA 10 nA 200 mV 50 + 18 150 + 30 150 + 30 150 + 30 0.15 + 0.1 1.0000000 A 100 nA 400 mV 150 + 50 400 + 50 400 + 50 400 + 50 0.15 + 0.1 3.000000 A 1 µA 1300 mV 200 + 40 400 + 40 400 + 40 400 + 40 0.15 + 0.1 10.000000A 41 1 µA 650 mV 700 + 275 800 + 275 1500 + 275 2000 + 275 50 + 10 NOTES 37. With line sync on. 38. 20% overrange supported for all ranges except for 3 A and 10 A, which are 1% supported. 39. Relative to calibration accuracy. 40. Add per degree from T CAL ±5°C. 41. Rear input terminals only. WWW.TEK.COM | 11 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Accuracy ±(ppm of reading + ppm of range) TCAL ±1°C 39 TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 40 10.000000 µA 1 pA 15 mV 30 + 30 100 + 30 125 + 40 175 + 50 10 + 8 100.00000 µA 10 pA 15 mV 20 + 5 75 + 12 100 + 15 150 + 20 10 + 3 1.0000000 mA 100 pA 15 mV 30 + 5 75 + 12 100 + 15 150 + 20 10 + 3 10.000000 mA 1 nA 20 mV 40 + 5 75 + 12 100 + 15 150 + 20 10 + 3 100.00000 mA 10 nA 200 mV 50 + 18 300 + 30 400 + 30 500 + 30 50 + 5
1.0000000 A 100 nA 400 mV 150 + 50 400 + 50 450 + 50 500 + 50 10 + 10
3.000000 A 1 µA 1300 mV 200 + 40 400 + 40 450 + 40 500 + 40 10 + 10
10.000000 A 41 1 µA 650 mV 700 + 275 800 + 275 1500 + 275 2000 + 275 50 + 10
RMS Noise (additional peak noise uncertainty) 42 Applies to ± ppm of range. Peak noise uncertainty is included in DC specifications for ≥1 PLC. Add peak noise uncertainty to measurements when <1 PLC. Examples 1 mA at 0.006 PLC: 9 (from Accuracy table) + 20 (additional peak noise uncertainty) = 29 ppm of range. 1 mA at 1 PLC: 9 +0 = 9 ppm of range. NPLC Digits 10 µA 100 µA 1 mA 10 mA 100 mA 1A 3A 10A 43 0.006 4½ 130 (350) 14 (42) 3 (20) 2 (20) 4 (30) 4 (31) 7 (51) 20 (110) 0.0005 3½ 260 (2110) 30 (300) 20 (150) 20 (160) 30 (190) 30 (190) 70 (510) 60 (420) DC Current Characteristics Range 10 µA 100 µA 1 mA 10 mA 100 mA 1 A 3 A 10 A 43 Effective Internal Shunt Value 45 1 kΩ 100 Ω 10 Ω 1 Ω 0.1 Ω 0.1 Ω 0.1 Ω 0.005 Ω Autozero Off Error: For ±1°C and ≤10 minutes add ±(8 ppm of reading + range error) 150 pA 1.5 nA 15 nA 150 nA 15 µA 150 µA 150 µA 3 mA Overload Recovery: For each additional sustained amp beyond ±1.5 A, add the following initial ppm of range error until thermally settled after overload recovery 15500 1800 150 150 6500 200 — — NOTES 42. Noise values are based on 1000 readings with autozero on and AMPS terminal open. RMS noise is typical. Additional peak noise is guaranteed. 43. Rear input terminals only. 44. With line sync on. 45. Values are typical and guaranteed by design. 12 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Types: 100 Ω platinum PT100, D100, F100, PT385, PT3916; or user-configurable 0 Ω to 10 kΩ. Type Range Resolution Accuracy ±°C
2 Year, TCAL ±5°C Temperature Coefficient 46
4-Wire RTD –200 to 850 °C 0.01 °C 0.06 °C 0.003 °C/°C 3-Wire RTD 47 –200 to 850 °C 0.01 °C 0.75 °C 0.003 °C/°C Thermistor Types: 2.252 kΩ, 5 kΩ, and 10 kΩ. Type Range Resolution Accuracy ±°C Thermistor –80 to +150 °C 0.01 °C 0.08 °C 0.002 °C/°C Thermocouple Types: B, E, J, K, N, R, S, T Accuracy ±°C Type Range Resolution
2 Year, TCAL ±5°C 48
Simulated Reference Junction Temperature Coefficient 46 B 350 to +1820 °C 0.1 °C 0.6 °C 0.03 °C/°C E −200 to +1000 °C 0.001 °C 0.2 °C 0.03 °C/°C J −200 to +760 °C 0.001 °C 0.2 °C 0.03 °C/°C K −200 to +1372 °C 0.001 °C 0.2 °C 0.03 °C/°C N −200 to +1300 °C 0.001 °C 0.2 °C 0.03 °C/°C R 0 to +1768 °C 0.1 °C 0.6 °C 0.03 °C/°C S 0 to +1768 °C 0.1 °C 0.6 °C 0.03 °C/°C T −100 to +400 °C 0.001 °C 0.2 °C 0.03 °C/°C Continuity Range 49 Resolution Test Current Open Circuit Voltage Accuracy ±(ppm of reading + ppm of range)
2 Year, TCAL ±5°C Temperature Coefficient 50
1.0000 kΩ 100 mΩ 1 mA 14.0 V 100 + 100 2.5 + 1 Continuity Characteristics Continuity High Limit User-selectable; default 10 Ω. NOTES 46. Add per degree from T CAL ±5°C; specifications without autocalibration. 48. Exclusive of cold-junction errors. 49. Specifications exclude lead resistance. 50. Add per degree from T CAL ±5°C; specifications without autocalibration. WWW.TEK.COM | 13 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Accuracies specified for additional cable and stray capacitance properly zeroed with the Rel function. Accuracy Range 51 Resolution Charge Current 52, 53 Maximum Circuit Voltage Accuracy ±(% of reading + % of range) 2 years TCAL ±5°C Temperature Coefficient 50 Diode Voltage Measure Range 51 Resolution Bias Level (Selectable) Accuracy ±(ppm of reading + ppm of range) TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 50 10.000000 V 1 µV 10 µA / 100 µA / 1 mA 20 + 5 30 + 5 45 + 5 2.5 + 1 Digitize Voltage Accuracy (Input Impedance AUTO) Range 54, 55 Resolution 56 Input Impedance 57 Accuracy ±(ppm of reading + ppm of range) TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 58 100.000 mV 1 µV >10 GΩ or 10 MΩ ±1% 210 + 100 220 + 100 230 + 100 15 + 20
1.00000 V 10 µV >10 GΩ or 10 MΩ ±1% 110 + 75 120 + 75 130 + 75 15 + 20
10.0000 V 0.1 mV >10 GΩ or 10 MΩ ±1% 110 + 75 120 + 75 130 + 75 10 + 20
100.000 V 59 1 mV 10 MΩ ±1% 110 + 75 120 + 75 130 + 75 15 + 20
1000.00 V 60 10 mV 10 MΩ ±1% 110 + 75 120 + 75 130 + 75 10 + 20
- 20% overrange on all ranges. 52. Charging current values are typical, guaranteed by design. 53. Discharge current limited to <13 mA. 54. For DC coupling, 20% overrange for 100 mV to 100 V. For AC coupling, 500% overrange 100 mV to 100 V. 1% for 1000 V range DC and AC coupling. 55. Accuracy with sample rate 1k per second, aperture auto, and 100 reading buffer average. 56. Power up default is 4½ digits. 57. User-selectable. 58. Add per degree from T CAL ±5%. 59. For 100 V range, input impedance auto and without ACAL, add 100ppm of range additional uncertainty and 15 ppm/°C additional uncertainty for “of range” temperature coefficient for operation outside of T CAL ±5°C. 60. For signal levels greater than 500 V, add 0.02 ppm/V to the ppm of the readings specification for measurements exceeding 500 V. 14 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Signal Characteristics 61, 62, 63 Typical AC and DC Coupled Range Analog Bandwidth (–3dB) Maximum Flatness Error
3 Hz to 20 kHz 64
(–1dB FS) 65 DC-coupled Settling Time (0.5%) AC-coupled Filter FAST Settling Time (0.5%) AC-coupled Filter SLOW Settling Time (0.5%) AC Coupling Low Frequency (–3dB) point 66 100.000 mV 600 kHz 0.015 dB 0.04 % 5 µs 80 ms 2.3 s 1 Hz 1.00000 V 600 kHz 0.01 dB 0.03 % 6 µs 80 ms 2.5 s 1 Hz 10.0000 V 600 kHz 0.01 dB 0.01 % 4 µs 80 ms 2.5 s 1 Hz Typical DC Coupled Range Analog Bandwidth (–3dB) Maximum Flatness Error
3 Hz to 1 kHz 64
Distortion (THD) 1 kHz Signal (–1dB FS) 65 Settling Time (0.5%) 100.000 V 20 kHz 67 0.1 dB 1.3 % 160 µs 1000.00 V 20 kHz 0.1 dB 1.8 % 80 µs Typical AC Coupled Range Analog Bandwidth (–3dB) Maximum Flatness Error
3 Hz to 20 kHz
(0.5%) Filter SLOW Settling Time (0.5%) Low Frequency Coupling Point 66 (–3dB) 100.000 V 600 kHz 0.1 dB 80 ms 2.3 s 1 Hz 1000.00 V 600 kHz 0.1 dB 80 ms 2.3 s 1 Hz DC-Coupled Additional Noise Uncertainty, DC-coupled Total Harmonic Distortion (THD), Typical 68 Typical 69 0.1 100 1000 1k 2k 5k 10k 20k 50k 100k 200k 500k 1M ppm of Range Samples per Second RMS Noise, Digitize Voltage 100 mV 1 V 10 V 100 V 1000 V -120 -110 -100 -90 -80 -70 -60 -50 1k 2k 5k 10k 20k 50k 100k 200k dB of Range Samples per Second Total Harmonic Distortion, Digitize Voltage 100 mV 1 V 10 V 100 V 1000 V NOTES 61. Accuracy with sample rate 1M per second and aperture 1 µs. 62. Verified with sine wave input and DC content ≤3% of range. 63. For AC coupling, maximum crest factor of 5. 65. Exclusive of source input noise. 66. With AC coupling frequency = 3 Hz and AC coupling filter = Slow. 67. For input impedance auto, bandwidth is 6 kHz. 68. Specified with aperture auto and 4-wire short on input terminals. For 100 V range, input impedance 10 MΩ, multiply by 2.5. For all ranges and sample rate >1 k, add an additional 3× RMS noise uncertainty to ppm of range. 69. Specified with aperture auto and 1 kHz sine wave input. Distortion is calculated using first five harmonics. WWW.TEK.COM | 15 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
DC-Coupled Effective Number Of Bits (ENOB), Typical 70 1k 2k 5k 10k 20k 50k 100k 200k Bits Samples per Second Effective Number of Bits (ENOB), Digitize Voltage 100mV 10V Digitize Current DC Accuracy 71 Range 72 Resolution 73 Burden Voltage Accuracy ± (ppm of reading + ppm of range) TCAL ±5°C TCAL ±5°C TCAL ±5°C Temperature Coefficient 74 10.0000 µA 0.1 nA 15 mV 150 + 75 160 + 75 170 + 75 30 + 15 100.000 µA 1 nA 15 mV 150 + 75 160 + 75 170 + 75 30 + 15 1.00000 mA 10 nA 15 mV 150 + 75 160 + 75 170 + 75 30 + 15 10.0000 mA 100 nA 20 mV 150 + 75 160 + 75 170 + 75 30 + 15 100.000 mA 1 µA 200 mV 340 + 100 450 + 100 560 + 100 50 + 20
1.00000 A 10 µA 400 mV 400 + 110 500 + 110 600 + 110 50 + 25
3.00000 A 100 µA 1300 mV 650 + 150 900 + 150 900 + 150 50 + 25
10.0000 A 75 100 µA 650 mV 950 + 350 1500 + 350 2000 + 350 50 + 25
- Specified with aperture Auto, 100Hz sine wave for sample rate ≤5k, and 1kHz sine wave for sample rate ≥10k. For the 100V and 1000V ranges, use the 1V and 10V range ENOB, respectively; guaranteed by design. 71. Accuracy with sample rate 1k per second, aperture auto, and 100 reading buffer average. 72. 20% overrange on all ranges except 3.3% for 3A and 10A ranges. 73. Power up default is 4½ digits. 74. Add per degree from T CAL ±5°C. 75. Rear input terminals only. 16 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Signal Characteristics, Typical 76 Range 72 Maximum Flatness Error (–3dB) Total Harmonic Distortion (THD) 20 kHz Signal (–1dB FS) DC-coupled Settling Time (0.5%) 10.0000 µA 0.15 dB 100 kHz 0.02 % 8 µs 100.000 µA 0.15 dB 100 kHz 0.01 % 7 µs 1.00000 mA 0.1 dB 100 kHz 0.01 % 3 µs 10.0000 mA 0.1 dB 100 kHz 0.01 % 8 µs 100.000 mA 0.1 dB 100 kHz 0.02 % 5 µs 1.00000 A 77 0.1 dB 100 kHz 0.02 % 6 µs 3.0000 A 77 0.1 dB 100 kHz 0.02 % 6 µs 10.0000 A 75, 77, 78 0.1 dB 100 kHz 0.02 % 6 µs Additional Noise Uncertainty, Typical 79 Total Harmonic Distortion (THD), Typical 80 100 1000 1k 2k 5k 10k 20k 50k 100k 200k 500k 1M ppm of Range Samples per Second RMS Noise, Digitize Current 10 µA 100 µA 1 mA 10 mA 100 mA, 1 A 3 A 10 A -120 -110 -100 -90 -80 -70 1k 2k 5k 10k 20k 50k 100k 200k dB of Range Samples per Second Total Harmonic Distortion, Digitize Current 10 µA 100 µA 1 mA 10 mA 100 mA Effective Number Of Bits (ENOB), Typical 81 1k 2k 5k 10k 20k 50k 100k 200k Bits Samples per Second Effective Number of Bits (ENOB), Digitize Current 10 µA 100 µA 1 mA 10 mA 100 mA NOTES 76. Verified with sine wave input and DC content ≤3% of range. 7 7. 10A range is available only on the rear input terminals. 78. 10A flatness verified to 10kHz; 100kHz guaranteed by design. 79. Specified with aperture Auto and open input terminals. For all ranges and for ≥1k sample rate, add an additional 3× RMS noise uncertainty to ppm of range. 80. Specified with aperture Auto and 1kHz sine wave input. Distortion is calculated using first five harmonics. For the 1A, 3A, and 10A ranges, use the 100mA range accuracy; guaranteed by design. 81. Specified with aperture Auto, 100 Hz sine wave for sample rate ≤5 k, and 1 kHz sine wave for sample rate ≥10 k. For the 1 A, 3 A, and 10 A ranges, use the 100 mA ENOB; guaranteed by design. WWW.TEK.COM | 17 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Maximum Resolution 18 bits. Measurement Input Coupling DC or AC (voltage only). Sampling Rate 82 Programmable 1 k through 1 million. Volatile Sample Memory with Timestamp 27.5 million. Minimum Record Time 1 µs. Timestamp Resolution 1 ns with standard or full buffer style. 1 µs with compact buffer style. Timestamp Accuracy With standard or full buffer style, 20 ns between adjacent readings, with total buffer time <2 s. With compact buffer style, 2 µs adjacent readings, with total buffer buffer time <2 s. Maximum Record Length 8 million. True RMS AC Voltage and AC Current Function Range 83 Resolution 1-Year Accuracy: ±(% of reading + % of range) T CAL ±5°C
3 Hz to
5 Hz to
10 Hz to
Coefficient/°C (all ranges) Function Range 83 Resolution 1-Year Accuracy: ±(% of reading + % of range) T CAL ± 5°C
3 Hz to 5 Hz 5 Hz to 10 Hz 10 Hz to 2 kHz 2 kHz to 5 kHz 5 kHz to 10 kHz
Coefficient/°C (all ranges) NOTES 82. Sample rate is not continuously adjustable. For valid discrete settings, see the DMM7510 Reference Manual. 83. 20% overrange on AC functions except 1% on 700 V, 3.33% on 3 A, and 1% on 10 A. Default resolution is 6½ digits. 84. Specifications are for detector bandwidth of 3Hz and sine wave inputs >5% of range. Detector bandwidth of 3 Hz and 30 Hz are multisample A/D conversions. Detector bandwidth of 300 Hz is a single A/D conversion, programmable from 0.0005 PLC to 15 PLC (60 Hz), 12 PLC (50 Hz). Default condition set to 1 PLC. 85. Rear terminals only. 18 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Additional AC Uncertainties – Low Frequency Uncertainty Additional Uncertainty ±(% of reading), Lower Frequency Uncertainty Detector Bandwidth (BW) 3 BW (3 Hz to 300 kHz) 30 BW (30 Hz to 300 kHz) 300 BW (300 Hz to 300 kHz) 20 Hz to 30 Hz 0 0.3 —
30 Hz to 50 Hz 0 0 —
50 Hz to 100 Hz 0 0 4.0 100 Hz to 200 Hz 0 0 0.72 200 Hz to 300 Hz 0 0 0.18 300 Hz to 500 Hz 0 0 0.07 > 500 Hz 0 0 0 Additional AC Voltage Crest Factor Uncertainties 86 Additional Uncertainty ±(% of reading) Input Signal Frequency Detector Bandwidth Maximum Crest Factor: 5 at Range Full Scale 1 to 2 2 to 3 3 to 4 4 to 5 3 Hz to 5 Hz 3 Hz 1.00 4.00 4.80 5.00 5 Hz to 10 Hz 3 Hz 0.50 1.20 1.30 1.40 10 Hz to 30 Hz 3 Hz 0.20 0.30 0.60 0.90 5 Hz to 100 Hz 30 Hz 0.20 0.30 0.60 0.90 100 Hz to 300 Hz 30 Hz 0.05 0.15 0.30 0.40 100 Hz to 300 Hz 300 Hz 0.50 1.20 1.30 1.50 500 Hz to 10 kHz 300 Hz 0.05 0.15 0.30 1.20 AC Voltage Characteristics Measurement Method AC-coupled, true RMS. Input Impedance 1 MΩ ± 2% || <150 pF. Volt*Hertz Product <2.1 × 107 V*Hz verified; input frequency verified for <300 kHz. AC Current Characteristics Measurement Method AC-coupled, true RMS. Range 1 mA 10 mA 100 mA 1 A 3 A 10 A 87 Burden Voltage (RMS) <16 mV <20 mV <0.2 V <0.4 V <1.3 V <0.65 V Overload Recovery: For each additional sustained ampere beyond ±1.5 A, add the following initial % of range error until thermally settled after overload recovery 0.006 0.006 0.12 0.05 — — NOTES 87. Rear input terminals only. WWW.TEK.COM | 19 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Aperture Measurement Resolution Accuracy, ±(ppm of reading + ppm of aperture time) Frequency: 3 Hz to 500 kHz Period: 333 ms to 2 µs
1 Year, TCAL ±5°C 2 Year, TCAL ±5°C
250 ms 0.1 ppm 80 + 0.333 160 + 0.333 100 ms 0.1 ppm 80 + 3.33 160 + 3.33 10 ms 0.1 ppm 80 + 33.3 160 + 33.3 Threshold Level Accuracy 89 Threshold Range Threshold Resolution Accuracy ±(% of reading)
2 Year, TCAL ±5°C
100 mV to 700 V 0.05% 1.0% Frequency and Period Characteristics Measurement Method Reciprocal counting technique. Aperture 10 ms to 273 ms; default is 10 ms. Typical Reading Rates, 60 Hz (50 Hz) Operation 90, 91, 92, 93 NPLC Digits Functions: DC Voltage (10 V), 2-wire Ohms (≤10 kΩ), DC Current (1 mA) Functions: 4-wire ohms (≤1 kΩ), 4-wire/3-wire RTD Functions: Thermistor Functions: Dry Circuit (≤1 kΩ) Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer 1 7½ 59.8 (49.8) 58 (48) 29 (24) 28 (24) 57 (48) 57 (48) 27 (23) 26 (22) 0.2 6½ 295 (240) 250 (210) 128 (109) 119 (100) 230 (200) 230 (200) 100 (89) 96 (85) 0.06 5½ 965 (810) 950 (800) 310 (280) 315 (280) 900 (750) 900 (750) 190 (180) 190 (180) 0.006 4½ 7500 (6700) 7300 (6500) 750 (730) 740 (720) 6800 (6000) 6800 (6000) 295 (290) 295 (290) 0.0005 3½ 26000 (26000) 24000 (24000) 860 (860) 860 (860) 18000 (18000) 18000 (18000) 310 (310) 310 (310) Detector Bandwidth (Hz) Digits Functions: ACV, ACI Measurements Into Buffer Measurements Into Computer 300 94 6½ 59.8 (49.8) 55 (46) 300 94 3½ 26200 (26200) 24500 (24500) NOTES 88. Specified for square wave inputs. Input signal must be >10% of ACV range. If input is <20 mV on the 100 mV range, then the frequency must be >10 Hz. For sine wave inputs, frequency must be >100 Hz. For frequencies ≤100 Hz, threshold level ≤50% of input signal and ≤7 Hz, threshold level ≤3% of range. 89. Threshold range is voltage RMS and threshold level voltage peak. Specified with 1kHz square wave. 100V and 700V threshold ranges guaranteed by design. 90. Reading speeds for autozero off, fixed range, autodelay off. Offset compensation off and open lead detector off where applicable. 91. Buffer measurements: For <0.2 PLC, multisample, single buffer transfer binary reading only. 92. PC measurements: For 1 and 0.2 PLC single reading and single transfer to computer (USB). 93. Reading rates using factory default operating conditions and autorange off, autodelay off. Speeds include measurement and data transfer out of the USB. ≥1000 readings with binary transfer over USB. 94. For bandwidth 300Hz, autozero off, 6½ digits at 1 PLC, 3½ digits at 0.0005 PLC. 20 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Digitize, Typical Sampling Rate Digits Resolution Measurements Into Computer 93 10 kS/s 5½ 18 9700 20 kS/s 4½ 16 19000 50 kS/s 4½ 16 44400 100 kS/s 4½ 15 80000
1 MS/s 3½ 12 108000
System Performance, Typical Mode 3½-digit, autozero off, 0.0005 PLC, excludes measurement time. Time includes function change from DC voltage or 2-wire ohms to listed function. Function Function Change (ms) Range Change (ms) DC Voltage or 2-wire ohms (<10 kΩ) 6 1.3 4-wire ohms (<10 kΩ) 7 1.3 DC Current 7 1.3 Frequency or Period 95 7 1.3 AC Voltage or AC Current 7 1.3 Digitize Voltage or Current 7 1.3 Ranges for Function Change Times Function change times apply to the ranges listed in the table below. Function Range DC Voltage 10 V 2-wire or 4-wire Ohms 1 kΩ DC Current 1 mA Dry-circuit Ohms 10 Ω Thermocouple Use DC Voltage rates Thermistor Use 2-wire Ohms rates AC Current 1 mA AC Voltage 1 V Buffer Transfer Speed (Binary) Measurements into Computer (per second) USB LAN GPIB Average for 1000 readings 280000 270000 190000 Average for 1000 readings with timestamp 170000 140000 100000 WWW.TEK.COM | 21 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Time Base Accuracy 25ppm. Trigger Source Analog DCV, DCI, or any system trigger. Trigger Coupling DC or AC (DCV function only). Input Trigger Latency 96, 97, 98 <225 ns. Input Trigger Jitter 96, 97 <50 ns. Sample period Jitter 96, 97 <1 ns. DMM Rear-Panel Triggers EXT TRIG IN and OUT 0 V to 5 V logic signal input and output, TTL compatible. EXT trigger latency (IN and OUT) <400 ns. EXT trigger latency (IN or OUT) <200 ns (guaranteed by design). Analog Triggering 99 Analog Level, Edge, Or Window Trigger Types 100 Trigger Characteristics Voltage Input Current Input Input 100 mV to 1000 V 10 µA to 10 A Resolution 0.05% 0.05% Basic Accuracy (T ACAL ±5°C) 101, 102 1% 1% Analog Trigger Latencies Digital I/O External Positive Logic 800 ns + 40 ns jitter 930 ns + 40 ns jitter Negative Logic 800 ns + 40 ns jitter 840 ns + 40 ns jitter Window Filter and Memory (buffer) Window Filter Size 0 to 10% of reading, where 0 averages all readings. Memory Up to 27.5 million timestamped readings with the compact buffer style, with additional memory available using an external USB flash drive. Maximum Internal Memory (Buffer) 27.5 million readings with the compact buffer style (6½-digit without formatting), 11 million readings with the standard or full buffer style. NOTES 95. For DC voltage or 2-wire ohms to frequency or period, 10ms aperture. For AC current or AC voltage, detector bandwidth is 300 Hz. 96. Guaranteed by design; for digital I/O only. 97. Stimulus command required to meet specifications. 98. If using trigger model, add 200 ns uncertainty. 99. For DC or AC coupled, the trigger level can be set up to 100% of measure range. 100. Rising or falling edge triggering supported. Window trigger requires setting two independent levels. 101. Trigger event occurs after the threshold crossing at a time determined by total trigger latencies. 102. Accuracy specifications require user ACAL and are verified with level trigger amplitude set to 50% of range with a 100 Hz sine wave at 100% full scale of range. High frequency rejection is off. current and digitized DC current 3 A or 10 A ranges, add an additional 2%. 22 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
General Instrument Specifications Specification Conditions This document contains specifications and supplemental information for the DMM7510 Precision Sampling Digital Multimeter instrument. Specifications are the standards against which the DMM7510 is tested. Upon leaving the factory, the DMM7510 meets these specifications. Supplemental, typical, and characteristic values are non-warranted, apply at 23°C, and are provided solely as useful information. All specifications apply to front or rear terminal inputs, except 10 A specifications (rear terminals only). Input Protection 1010 V DC (715 V RMS V AC) all ranges and functions on HI and LO terminals; 350 V all ranges and functions on sense HI, sense LO terminals; 250 V rated current input terminal; fused 3 A and 10 A ranges; current input terminals protected to 1 kV. 3 A Input Fuse Protection 3.5 A, 1 kV fast blow type. 10 A Input Fuse Protection 11 A, 1 kV fast blow type. AC Voltage input Maximum DCV: 1000V on any AC voltage range. Common Mode Isolation 500 VDC or ACVpeak LO to chassis. All terminals >10 GΩ, <350 pF any terminal to chassis. Power Line Universal input, 100 V to 240 V. Line Frequency 50 Hz or 60 Hz, automatically sensed at power-up. Power Consumption 60 VA. Operating Environment Specified for 0° to 50°C, ≤80% relative humidity at 35°C, altitude up to 2000 meters. Storage Environment –30° to 70°C. Real Time Clock Lithium battery backup (3+ years battery life). EMC Conforms to European Union EMC Directive. Safety NRTL listed to UL61010-1, and CSA C22.2 No 61010-1; conforms with European Union Low Voltage Directive. Vibration MIL -PRF-28800F Class 3, Random. Warm-up 90 minutes to rated accuracy. Input Signal Connections Front and rear safety banana jacks. Cooling Forced air, fixed speed. With handle and bumpers (bench configuration): 106 mm high × 255 mm wide × 425 mm deep (4.18 in. × 10.05 in. × 16.75 in.). Shipping weight (with bumpers and handle) 4.08 kg (9.0 lb.). Shipping weight (without bumpers and handle) 3.63 kg (8.0 lb.). Digital I/O: Connector 9-pin female D. 5V Power Supply Pin Limited to 500 mA at > 4 V (solidstate fuse protected). Lines Six input/output, user-defined, for digital I/O or triggering. Input Signal Levels: 0.7 V (maximum logic low) 3.7 V (minimum logic high). Input Voltage Limits: –0.25 V (absolute minimum) +5.25 V (absolute maximum). Maximum Source Current +2.0 mA at >2.7 V (per pin). Maximum Sink Current –50 mA at 0.7 V (per pin, solid-state fuse protected). Handler User-defined start of test, end of test, four category bits Math Functions Rel, dB, Limit Test, Percentage, 1/x, and mX + b. Remote Interface: WWW.TEK.COM | 23 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
LAN RJ-45 connector, 10/100BT; Virtual Front Panel. IP Configuration Static or DHCP. GPIB IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Device (rear panel, type B) 2.0 full speed, USBTMC compliant. USB Host (front panel, type A) USB 2.0, support for flash drives, FAT 32. LXI Compliance LXI version 1.4 Core 2011. Language Embedded Test Script Processor (TSP) accessible from any host interface; responds to high-speed test scripts comprised of remote commands and statements (for example, branching, looping, math); able to execute high- speed test scripts stored in memory without host intervention; also SCPI (default command set). Accessories Supplied Product Information CD-ROM, DMM7510 Quick Start Guide, power cord, 1 m USB cable (type A to type B), and 3 m LAN cable. Accessories Available (Calibration / Data / ISO 17025), software IVI/VISA drivers for Microsoft ® Visual Basic ®, Visual C/C++ ®, National Instruments (NI™) LabVIEW™, Keithley TSP Toolkit Software, Keithley KickStart Instrument Control Software, and NI LabWindows™/CVI. Display Five-inch capacitive touch, color thin-film-transistor (TFT) WVGA (800×480) with LED backlight. Password Protection 30 characters. Expansion Interface The TSP-Link ® expansion interface allows TSP-enabled instruments to trigger and communicate with each other. IP configuration Static or DHCP (manual or automatic).
Ordering Information
DMM7510 7½-Digit Graphical Sampling Multimeter DMM7510-RACK 7½-Digit Graphical Sampling Multimeter, with No Handle Supplied Accessories DMM7510 QuickStart Guide TSP Toolkit Software (available at ww w.tek.com) LabVIEW and IVI Drivers (available at ww w.tek.com) 24 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
1754 2-Wire Universal 10-Piece Test Lead Kit
5804 Safety Universal Test Lead Kit
5805 Kelvin (4-Wire) Spring-Loaded Probes
5806 Kelvin Clip Lead Set
5808 Low Cost Single-pin Kelvin Probe Set
Cables, Connectors, Adapters CA-18-1 Shielded Dual Banana Cable, 1.2 m (4 ft.) Communication Interfaces & Cables KPCI-488LPA IEEE-488 Interface for PCI Bus KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter 7007-1 Shielded GPIB Cable, 1 m (3.2 ft) Triggering and Control 8501-1 Trigger Link Cable, DIN-to-DIN, 1 m (3.2 ft.)
8503 DIN-to-BNC Trigger Cable
4299-8 Single Fixed Rack Mount Kit 4299-9 Dual Fixed Rack Mount Kit WWW.TEK.COM | 25 DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
DMM7510-EW 1 Year Factory Warranty Extended to 2 Years from Date of Shipment DMM7510-3Y-EW 1 Year Factory Warranty Extended to 3 Years from Date of Shipment DMM7510-5Y-EW 1 Year Factory Warranty Extended to 5 Years from Date of Shipment Calibration Contracts C/DMM7510-3Y-17025 KeithleyCare 3 Year ISO-17025 Calibration Plan C/DMM7510-3Y-DATA KeithleyCare 3 Year Calibration w/Data Plan C/DMM7510-3Y-STD KeithleyCare 3 Year Std Calibration Plan C/DMM7510-5Y-17025 KeithleyCare 5 Year ISO-17025 Calibration Plan C/DMM7510-5Y-DATA KeithleyCare 5 Year Calibration w/Data Plan C/DMM7510-5Y-STD KeithleyCare 5 Year Std Calibration Plan C/NEW DATA Calibration Data for New Units C/NEW DATA ISO ISO-17025 Calibration Data for New Units Warranty Information Warranty Summary This section summarizes the warranties of the DMM7510. For complete warranty information, refer to the DMM7510 Reference Manual. Any portion of the product that is not manufactured by Keithley is not covered by this warranty and Keithley will have no duty to enforce any other manufacturer’s warranties. Hardware Warranty Keithley Instruments, Inc. warrants the Keithley manufactured portion of the hardware for a period of one year from defects in materials or workmanship; provided that such defect has not been caused by use of the Keithley hardware which is not in accordance with the hardware instructions. The warranty does not apply upon any modification of Keithley hardware made by the customer or operation of the hardware outside the environmental specifications. Software Warranty Keithley warrants for the Keithley produced portion of the software or firmware will conform in all material respects with the published specifications for a period of ninety (90) days; provided the software is used on the product for which it is intended in accordance with the software instructions. Keithley does not warrant that operation of the software will be uninterrupted or error-free, or that the software will be adequate for the customer’s intended application. The warranty does not apply upon any modification of the software made by the customer. 26 | WWW.TEK.COM DATASHEETDMM7510 7½-Digit Graphical Sampling Multimeter
Find more valuable resources at TEK.COM in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.
121724 SBG 1KW-60022-3
Contact Information: Australia 1 800 709 465 Austria* 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3530-8901 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3086 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 88 69 35 25 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People’s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 565 1455 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Rev. 02.2022