TCP-RK-BBU-24-41 is a component documented by TECHNOLOGY ASSISTANCE B. The PDF description identifies it as "BATTERY BACK-UP POWER SUPPLY." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.

Datasheet snapshot

  • Manufacturer: TECHNOLOGY ASSISTANCE B...
  • Part number: TCP-RK-BBU-24-41
  • Category: IC
  • Datasheet length: 2 Pages

Applications listed in the PDF

  • Universal AC Input/Full range
  • Active PFC for EN61000-3-2,-3
  • Built In Batteries
  • Current Share Function
  • DC Good Signals
  • Remote on/off & Remote Sense Functions

Specifications and operating details

The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.

  • SPECIFICATIONS TD RSP-1URK-BBU SERIES BATTERY BACK-UP POWER SUPPLY INPUT SPECIFICATIONS: ENVIRONMENTAL SPECIFICATIONS Input: Universal AC Input Range 90-264VAC Input Frequency: 47-63Hz (400Hz Optional) Inrush Cur rent: 25A max at 115VAC/40.
  • Der ate to 50% at +70°C Storage Temperature: -40°C to + 85°C max 95 % Relative Humidity Cooling: Internal ball bearing DC fan Humidity: 20-90% RH non condensing Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes) Shock: 20G Peak Accel.
  • OUTPUT SPECIFICATIONS Adjustment Range: ± 10% (minimum) Minimum Load: none Regulation: Line±0.5% Load ±0.5% Ripple/Noise: 150mV peak to peak maximum (20 MHz) Set Point Accuracy: ± 1%(except 5V=±2%) (maximum) Output voltage adj: ±10% minimu.
  • 90 °C ± 5°C Auto Recovery STANDARD FEATURES Universal AC Input/Full range Active PFC for EN61000-3-2,-3 Built In Batteries Current Share Function DC Good Signals Remote on/off & Remote Sense Functions Low Voltage Battery Disconnect Paralle.

Topics covered by the datasheet

The document includes sections related to:

  • APPLICATIONS

Engineering review checklist

  • Confirm repetitive reverse voltage, average forward current, surge current and leakage at the intended temperature.
  • Check forward-voltage loss and reverse-recovery behavior at the actual current and switching frequency.
  • Review package thermal resistance, copper area, polarity marking and transient derating before layout release.

Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.

View the complete PDF and model record

Open the TCP-RK-BBU-24-41 datasheet and model details to review the complete PDF, document pages and available product information.

Source attribution

Adapted from the PDF associated with this DigiCamel model page.

Source model URL: https://www.digicamel.com/product.php?slug=tcp-rk-bbu-24-41-technology-assistance-b