SLA8.100 overview
SLA8.100 is a component documented by PULS GmbH. The PDF description identifies it as "AS-Interface Power Supply." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.
Datasheet snapshot
- Manufacturer: PULS GmbH
- Part number: SLA8.100
- Category: Interface
- Datasheet length: 4 Pages
Specifications and operating details
The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.
- 5s) Load regulation stat. <200mV (no load / full load) Ripple 50mV PP (500kHz bandw., 50Ω measurem., ohmic load) Noise (Spikes) 100mV PP (20MHz bandw., 50 Ω measurem., ohmic load) Overvoltage protection limited to max.
- 55V Operating indicator Green LED (extinguishes at overload) Output is protected against short-circuit, open circuit and overload.
- The communica- tion signals of the individual network participants are modulated onto the supply voltage.
- Shutdown: At overtemperature, overload or short-circuit (8.4A < Imax < 12A), the unit switches off the output after 2...5s Indicator: Activation of the FUSE Mode is indicated by a flashing red LED Reset / Restart: by intentionally pu.
- Non-operating temperature range -25°C...+85°C Operating temperature range -10°C...+70°C (measured at 25mm below the unit) Derating from 60°C 6W/°C onwards, power reduction necessary (see diagram) Cooling natural convection, no forced air-c.
- 21.2W (AC 230V, 8A) L N Transient- Inrush- and EMC- Filter Input Rectifier and Hold-up Capacitor V DC to DC Converter DC DC AS-i Decoupling Network Infrared (IR) Addressing Mode AS-i + Shield AS-i + AS-i - AS-i - Mode Selector: Communicati.
- 6A or slower action, or alternatively 6A HBC fuse Mounting position vertical; input below, output above Free space for cooling above / below 25mm recommended left / right 15mm recommended Always connect PE before operating the unit!
Topics covered by the datasheet
The document includes sections related to:
- applications
Engineering review checklist
- Check resistance value, tolerance, temperature coefficient and long-term stability over the operating range.
- Derate continuous power for ambient temperature and verify pulse or surge capability separately.
- Match the land pattern, termination finish and current-sense routing to the exact package option.
Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.
View the complete PDF and model record
Open the SLA8.100 datasheet and model details to review the complete PDF, document pages and available product information.
Source attribution
Adapted from the PDF associated with this DigiCamel model page.
Source model URL: https://www.digicamel.com/product.php?slug=sla8-100-puls-gmbh