PL601P overview

PL601P is a component documented by Thurlby Thandar Instrum. The PDF description identifies it as "New PL series - advanced linear regulated laboratory power supplies." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.

Datasheet snapshot

  • Manufacturer: Thurlby Thandar Instrum...
  • Part number: PL601P
  • Category: IC
  • Datasheet length: 9 Pages

Specifications and operating details

The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.

  • Most linear regulated power supplies offer low output noise with figures below 2mV rms being typical.
  • The New PL series goes a stage further and an rms noise figure of 0.4mV with tightly specified pk-pk noise and common-mode current figures.
  • Vmin and Vmax can be set anywhere between zero and maximum output voltage subject only to Vmax > (Vmin + 0.1V).
  • Low current range gives 0.1mA meter resolution and finer low current setting.
  • Safety binding post termi- nals can accept fixed-shroud 4mm plugs** as well as normal plugs, bare wires, and fork connectors.
  • Consequently all operations that could result in an unexpected change in voltage or current settings have intelligent interlocks to prevent this. ** Safety terminals The use of fixed-shroud 4mm plugs is becoming mandatory within an increas.
  • The range for Vmax is 0.1V to 15V/30V/60V depending on model.

Topics covered by the datasheet

The document includes sections related to:

  • PL-P AIM-TTI

Engineering review checklist

  • Confirm the exact ordering code, package, pinout or terminal arrangement and document revision.
  • Compare recommended operating conditions with absolute maximum ratings and retain adequate design margin.
  • Validate electrical, thermal, mechanical and environmental behavior in the final application.

Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.