PGH200N8 overview
PGH200N8 is a component documented by Kyocera Kinseki Corpota. The PDF description identifies it as "Thyristor." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.
Datasheet snapshot
- Manufacturer: Kyocera Kinseki Corpota...
- Part number: PGH200N8
- Category: IC
- Datasheet length: 9 Pages
Specifications and operating details
The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.
- Rated Value 単位 Unit 平均出力電流 Average Rectified Output Current Io (AV) ୕相全波整流 3-Phase Full Wave Rectified TC= 102し㸧 Non-Biased for Thyristor 200 A TC= 77℃㸦電圧印加あり㸧 Biased for Thyristor 200 動作接合温度範囲 Operating Junction Temperature Range Tjw 125~.
- Rated Value 単位 Unit 㡰電流 *1 Surge Forward Current IFSM 50Hzṇ弦半波㸪1㺙㺐㺖㺷㸪非くり返し Half Sine Wave, 1Pulse, Non-Repetitive 2000 A 電流乗時間積 *1 I Squared t I2t 2~10ms 20000 A2s 許容周波数 Allowable Operating Frequency f 400 Hz *1:1値 Value Per 1 Arm.
- サイリࢫࢱ部(1素子) Part of Thyristor(1 Arm.) ■最大定格 Maximum Rating 㡯 目 Parameter 記 号 Symbol 定格値 Max.Rated Value 単位 Unit 電圧 *2 Repetitive Peak Off-State Voltage VDRM 800 V 電圧 *2 Non-Repetitive Peak Off-State Voltage VDSM 900 V *2いこと Can not be Bias.
- Rated Value 単位 Unit オン電流 Surge On-State Current ITSM 50Hzṇ弦半波㸪1㺙㺐㺖㺷㸪非くり返し Half Sine Wave, 1Pulse, Non-Repetitive 4000 A 電流乗時間績 I Squared t I2t 2~10ms 80000 A2s 臨界オン電流ୖ昇率 Critical Rate of Rise of Turned-On Current di/dt VD = 2/3 VDRM, ITM.
- VOLTAGE 順 電 圧 特 性 PGH200N8 (per Arm) 0 1 2 3 4 5 INSTANTANEOUS FORWARD VOLTAGE (V) 瞬 時 順 電 圧 㸦㹔㸧 100 200 500 1000 2000 INSTANTANEOUS FORWARD CURRENT (A) 瞬 時 順 電 流 㸦A㸧 Tj=25°C Tj=150°C FORWARD CURRENT VS.
- P㹅M = 5W f Ӎ 50㹆z duty ӌ 20% -40℃ +25℃ +125℃ Transient Thermal Impedance 過 渡 熱 抵 抗 特 性 PGH200N8(Diode Per 1 Arm.) Time t (s) 時間 t (s) 0.02 0.05 0.1 0.2 0.5 Transient Thermal Impedance Rth(j-c) (°C/W) 過 渡 熱 抵 抗 㸦゚(/W㸧 Transient Thermal Impe.
Engineering review checklist
- Confirm repetitive reverse voltage, average forward current, surge current and leakage at the intended temperature.
- Check forward-voltage loss and reverse-recovery behavior at the actual current and switching frequency.
- Review package thermal resistance, copper area, polarity marking and transient derating before layout release.
Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.
View the complete PDF and model record
Open the PGH200N8 datasheet and model details to review the complete PDF, document pages and available product information.
Source attribution
Adapted from the PDF associated with this DigiCamel model page.
Source model URL: https://www.digicamel.com/product.php?slug=pgh200n8-kyocera-kinseki-corpota